Commit Graph

474 Commits

Author SHA1 Message Date
Ben Kochie
d33a447047
Remove deprecated prometheus.InstrumentHandlerFunc (#831)
Update Prometheus client golang use to use `promhttp.Handler()` instead
of `prometheus.InstrumentHandlerFunc()`.
2018-02-19 15:44:59 +01:00
Richard Elling
d7348a5c78 updates for zfsonlinux 0.7.5 (#779)
* updates for zfsonlinux 0.7.5

* add constants for KSTAT_DATA_* types

* added e2e test for negative values represented by uint64 that can result from ZFS bugs
2018-02-16 15:46:31 +01:00
Ben Kochie
6468e7c80b
Enable NFS client metrics by default. (#828)
Enable NFS client metrics by default now that it nolonger prints errors
on scrape if there are no metrics to display.

Also fixup the nfsd README to match the nfs entry.
2018-02-16 15:42:47 +01:00
Ralf Horstmann
8d9c7ca659 Use swpginuse instead of swpgonly in meminfo_openbsd (#813)
All tools in OpenBSD base system use swpginuse instead of swpgonly
for reporting swap usage (snmpd, swapctl, top, vmstat), so let
memory collector use that as well for consistency.
2018-02-16 11:34:41 +01:00
Kasinath Kottukkal
f6965e1812 Add overlay to defIgnoredFSTypes (#824)
* Add overlay to defIgnoredFSTypes

To avoid statfs() errors if node_exporter is running as non privileged user.

* Updated defIngoredFSTypes values in sorted order
2018-02-16 09:47:50 +01:00
Ben Kochie
01bd99fb1a
Refactor NFS client collector (#816)
* Update vendor github.com/prometheus/procfs/...

* Refactor NFS collector

Use new procfs library to parse NFS client stats.

* Ignore nfs proc file not existing.

* Refactor with reflection to walk the structs.
2018-02-15 13:40:38 +01:00
Brian Brazil
52c031890e
Add _seconds suffix to node_time. (#823) 2018-02-14 16:59:08 +00:00
Ben Kochie
05eabe60fb
Fix error output in nfsd collector. (#821) 2018-02-14 13:57:35 +01:00
Ben Kochie
3de2542d21
Fix NFSd metric type (#819)
RPC Count should be a counter, not a gauge.
2018-02-13 17:03:22 +01:00
Matt Layher
544488ddd6 Fix remaining metric naming issues (#799) 2018-02-12 18:53:31 +01:00
Ben Kochie
6a041692ed
Add NFS Server metrics collector. (#803)
* Add NFS Server metrics collector.

* Add File Handles metrics.

* Add nfsd IO stats.

* Add metrics for NFSd threads.

* Add metrics for NFSd read ahead cache.

* Add NFSd network traffic counters.

* Add RPC metrics.

* Add V2 requests metrics.

* Add NFSv3 metrics.

* Add NFSv4 metrics.

* Update reply cache comment.

* Update help text.
2018-02-12 17:56:05 +01:00
Brian Brazil
1072f2868d Fix log level regression in #533 2018-02-07 15:16:20 +00:00
Brian Brazil
7e41a2b279 Ignore /var/lib/docker by default. (#814)
The node exporter runs unprivileged, so it cannot statfs any filesystems
under this directory causing log spam.  In addition there tends to be
high churn in the filesystems here (as it's basically application
monitoring) which can cause high cardinaltiy and in one case caused
Prometheus's index symbol table to get very large.
Accordingly this should be ignored to reduce log spam and avoid
performance issues. The filesystems themselves can in principle be
monitored via container oriented exporters, and the underlying
filesystems will still be monitored.
2018-02-06 17:10:59 +01:00
Ralf Horstmann
29ac809e48 Use unified CPU metric description on OpenBSD (#810) 2018-02-01 23:59:19 +01:00
Derek Marcotte
fde5d2c6c9 Remove unsafe typecasts from sysctl_bsd getStructTimeval. (#741)
There is a simpler way.
2018-02-01 18:43:40 +01:00
Ben Kochie
14d60958d6
Unify CPU collector conventions (#806)
* Unify CPU collector conventions

Add a common CPU metric description.
* All collectors use the same `nodeCpuSecondsDesc`.
* All collectors drop the `cpu` prefix for `cpu` label values.

* Fix subsystem string in cpu_freebsd.

* Fix Linux CPU freq label names.
2018-02-01 18:42:20 +01:00
Ralf Horstmann
e3c76b1f0c Add OpenBSD CPU collector (#805) 2018-02-01 18:33:49 +01:00
Tom Wilkie
6833eec187 Fix tests. 2018-01-31 15:22:17 +00:00
Tom Wilkie
0316bacceb Only use one dbus connection, required some refactoring. 2018-01-31 15:19:18 +00:00
Tom Wilkie
a7fd6b8743 Export systemd timer last trigger sec. 2018-01-31 15:07:04 +00:00
Ben Kochie
111e3af437
Remove obsolete megacli collector. (#798)
This collector has been replaced by the textfile collector tool
`storcli.py`.
2018-01-23 11:25:42 +01:00
Julius Volz
6cac74f0e0
Add unit suffix to textfile collector mtime metric (#796) 2018-01-22 14:02:19 +01:00
Brian Brazil
a98067a294 Make metrics better follow guidelines (#787)
* Improve stat linux metric names.

cpu is no longer used.

* node_cpu -> node_cpu_seconds_total for Linux

* Improve filesystem metric names with units

* Improve units and names of linux disk stats

Remove sector metrics, the bytes metrics cover those already.

* Infiniband counters should end in _total

* Improve timex metric names, convert to more normal units.

See
3c073991eb/kernel/time/ntp.c (L909)
for what stabil means, looks like a moving average of some form.

* Update test fixture

* For meminfo metrics that had "kB" units, add _bytes

* Interrupts counter should have _total
2018-01-17 17:55:55 +01:00
Ben Kochie
b4d7ba119a
Add fixture for ppc64le (#785)
* Add support for per-architecture fixtures.
* Add output for ppc64le.
2018-01-11 13:56:19 +01:00
Nick Owens
0629a081db multiply page size after float64 coercion to avoid signed integer overflow (#780) 2018-01-08 15:36:49 +01:00
Franz Pletz
d432f9857e Use uint64 in the ZFS collector (#714)
ZFS metrics can also be unsigned 64-bit integers that won't fit in
int64 and causes the whole collector to fail.
2018-01-06 12:36:55 +01:00
Derek Marcotte
477fe4665a Move FreeBSD/DragonflyBSD out of meminfo add kvm. (#547)
* Move FreeBSD/DragonflyBSD out of meminfo add kvm.

This gives us SwapUsed, and everything under one roof.

* Fix typos per review.

* Update to use newer API.

* Remove premature optimization per PR feedback.
2018-01-04 12:23:26 +01:00
Sevag Hanssian
4329b0a86b Add summary metrics for systemd exporter (#765) 2018-01-04 11:49:36 +01:00
Matthieu Guegan
d6ef10bb56 Add openbsd meminfo (#724)
* Implements meminfo collector for OpenBSD

This is a rework of #151.

* Fix CGO import

* Add some useful metrics

* Rename total -> size for normalization
2018-01-04 10:32:08 +01:00
Ben Kochie
7f6c59e198
Ignore more virtual filesystems (#775)
Add additional Linux virtual filesystem types to the default list.
2018-01-03 17:22:02 +01:00
Netmonk
2aa8d0eb0c [FIX] Exclude Linux proc from filesystem type regexp (#774)
* [FIX] Issue 63, error on excluding proc filesystem on linux, improving regexp

* [FIX] Reordering filter order
2018-01-03 11:40:32 +01:00
Julius Volz
f536857ac6
Fix e2e tests after textfile custom timestamp removal (#768) 2017-12-24 11:54:33 +01:00
Shubheksha Jalan
1f2458f42c Filter out testfile metrics correctly when using collect[] filters (#763)
* remove injection hook for textfile metrics, convert them to prometheus format

* add support for summaries

* add support for histograms

* add logic for handling inconsistent labels within a metric family for counter, gauge, untyped

* change logic for parsing the metrics textfile

* fix logic to adding missing labels

* Export time and error metrics for textfiles

* Add tests for new textfile collector, fix found bugs

* refactor Update() to split into smaller functions

* remove parseTextFiles(), fix import issue

* add mtime metric directly to channel, fix handling of mtime during testing

* rename variables related to labels

* refactor: add default case, remove if guard for metrics, remove extra loop and slice

* refactor: remove extra loop iterating over metric families

* test: add test case for different metric type, fix found bug

* test: add test for metrics with inconsistent labels

* test: add test for histogram

* test: add test for histogram with extra dimension

* test: add test for summary

* test: add test for summary with extra dimension

* remove unnecessary creation of protobuf

* nit: remove extra blank line
2017-12-23 20:21:58 +01:00
Ben Kochie
cd2a17176a
Add full make to CircleCI (#761)
* Add full make to CircleCI

Ensure end-to-end test is run.

* Fix go fmt error.

* Fix end-to-end output.
2017-12-21 16:24:23 +01:00
Wei Li
1e9bb4ec3a textfile: fix duplicate metrics error (#738)
The textfile gatherer should only be added to gatherer list once.

Signed-off-by: Li Wei <liwei@anbutu.com>
2017-12-06 17:05:40 +01:00
Kristian Klausen
a96f1738b3 netdev: Change valueType to CounterValue (#749)
All the metric only goes up, so the type should be counter.
This also add _total to all the metric name.

Fix: #747
2017-12-06 13:58:35 +01:00
Ben Kochie
2a80537547
Split out guest cpu metrics on Linux. (#744)
Linux "guest" metrics for VMs are already accounted for in node_cpu
`user` and `nice` metrics.  Separate these into their own metric to
avoid duplication of data.
2017-11-23 15:04:47 +01:00
Karsten Weiss
a8d7d1101a cpu: Support processor-less (memory-only) NUMA nodes (#734)
* cpu: Support processor-less (memory-only) NUMA nodes

Processor-less (memory-only) NUMA nodes exist e.g. in systems that use
Intel Optane drives for RAM expansion using Intel Memory Drive
Technology (IMDT).

IMDT RAM expansion supports two modes:

* "Unify Remote Memory domains": present a processor-less (memory-only)
  NUMA domain, which is the default
* "Expand local memory domains": to expand each processor’s memory domain
  with a portion of the memory made available by Optane and IMDT

This commit fixes a crash in the first case (when "cpulist" is empty).

Here's an example of such a system:

$ numastat -m|head -n5

Per-node system memory usage (in MBs):
                          Node 0          Node 1          Node 2           Total
                 --------------- --------------- --------------- ---------------
MemTotal               118239.56       130816.00       464384.00       713439.56

$ for i in {0..2}; do echo -n "$i: " ; cat /sys/bus/node/devices/node$i/cpulist ; done
0: 0-7,16-23
1: 8-15,24-31
2:

$ /opt/vsmp/bin/vsmpversion -vvv
Memory Drive Technology: 8.2.1455.74 (Sep 28 2017 13:09:59)
System configuration:
    Boards:      3
       1 x Proc. + I/O + Memory
       2 x NVM devices (Intel SSDPED1K375GAQ)
    Processors:  2, Cores: 16, Threads: 32
        Intel(R) Xeon(R) CPU E5-2667 v4 @ 3.20GHz Stepping 01
    Memory (MB): 713472 (of 977450), Cache: 251416, Private: 12562
       1 x 249088MB   [262036/   678/12270]
       1 x 232192MB   [357707/125369/  146]  82:00.0#1
       1 x 232192MB   [357707/125369/  146]  83:00.0#1

* cpu: rename some variables (pkg => node)

* cpu: Use %v not %q in log.Debugf() format strings
2017-11-10 15:31:26 +01:00
Matt Layher
f6f9c8d6cc Add and use sysReadFile in hwmon collector (#728) 2017-11-07 07:49:37 +01:00
Tobias Klauser
d73f1e60c4 Simplify Utsname string conversion (#716)
* Update golang.org/x/sys/unix

This allows to use simplified string conversion of Utsname members.

* Simplify Utsname string conversion

Use Utsname from golang.org/x/sys/unix which contains byte array
instead of int8/uint8 array members. This allows to simplify the string
conversions of these members.
2017-11-02 11:57:14 +01:00
Ben Kochie
ea250d73f4
Fix off by one in Linux interrupts collector (#721)
* Fix off by one in Linux interrupts collector

* Fix off by one in CPU column handler.
* Add test.

* Enable interrupts in end-to-end test.
2017-11-02 09:59:46 +01:00
Matt Layher
296b62acb7
netstat: return nothing when /proc/net/snmp6 not found 2017-10-31 15:26:32 -04:00
Derek Marcotte
0eecaa9547 Correct buffer_bytes > INT_MAX on BSD/amd64. (#712)
* Correct buffer_bytes > INT_MAX on BSD/amd64.

The sysctl vfs.bufspace returns either an int or a long, depending on
the value.  Large values of vfs.bufspace will result in error messages
like:

  couldn't get meminfo: cannot allocate memory

This will detect the returned data type, and cast appropriately.

* Added explicit length checks per feedback.

* Flatten Value() to make it easier to read.

* Simplify per feedback.

* Fix style.

* Doc updates.
2017-10-25 20:55:22 +02:00
Matt Layher
f9ad88fc03
xfs: expose correct fields, fix metric names 2017-10-20 18:41:51 -04:00
Siavash Safi
f3a7022602 Add collect[] parameter (#699)
* Add `collect[]` parameter

* Add TODo comment about staticcheck ignored

* Restore promhttp.HandlerOpts

* Log a warning and return HTTP error instead of failing

* Check collector existence and status, cleanups

* Fix warnings and error messages

* Don't panic, return error if collector registration failed

* Update README
2017-10-14 14:23:42 +02:00
Ben Kochie
deadfef4c9 Update vendoring (#685)
* Update vendor github.com/coreos/go-systemd/dbus@v15

* Update vendor github.com/ema/qdisc

* Update vendor github.com/godbus/dbus

* Update vendor github.com/golang/protobuf/proto

* Update vendor github.com/lufia/iostat

* Update vendor github.com/matttproud/golang_protobuf_extensions/pbutil@v1.0.0

* Update vendor github.com/prometheus/client_golang/...

* Update vendor github.com/prometheus/common/...

* Update vendor github.com/prometheus/procfs/...

* Update vendor github.com/sirupsen/logrus@v1.0.3

Adds vendor golang.org/x/crypto

* Update vendor golang.org/x/net/...

* Update vendor golang.org/x/sys/...

* Update end to end output.
2017-10-05 16:20:47 +02:00
Brett Vickers
b62c7bc0ad Updated vendored ntp package (#681)
The github.com/beevik/ntp package was recently updated with some
API changes that broke node_exporter. This commit fetches the
latest version of the ntp package and brings node_exporter in
line with the latest API.
2017-10-04 08:33:49 +02:00
Calle Pettersson
859a825bb8 Replace --collectors.enabled with per-collector flags (#640)
* Move NodeCollector into package collector

* Refactor collector enabling

* Update README with new collector enabled flags

* Fix out-of-date inline flag reference syntax

* Use new flags in end-to-end tests

* Add flag to disable all default collectors

* Track if a flag has been set explicitly

* Add --collectors.disable-defaults to README

* Revert disable-defaults flag

* Shorten flags

* Fixup timex collector registration

* Fix end-to-end tests

* Change procfs and sysfs path flags

* Fix review comments
2017-09-28 15:06:26 +02:00
Sami Kerola
3762191e66 Add timex collector (#664)
This collector is based on adjtimex(2) system call.  The collector returns
three values, status if time is synchronised, offset to remote reference,
and local clock frequency adjustment.

Values are taken from kernel time keeping data structures to avoid getting
involved how the synchronisation is implemented.  By that I mean one should
not care if time is update using ntpd, systemd.timesyncd, ptpd, and so on.
Since all time sync implementation will always end up telling to kernel what
is the status with time one can simply omit the software in between, and
look results of the syncing.  As a positive side effect this makes collector
very quick and conceptually specific, this does not monitor availability of
NTP server, or network in between, or dns resolution, and other unrelated
but necessary things.

Minimum set of values to keep eye on are the following three:

    The node_timex_sync_status tells if local clock is in sync with a remote
    clock.  Value is set to zero when synchronisation to a reliable server
    is lost, or a time sync software is misconfigured.

    The node_timex_offset_seconds tells how much local clock is off when
    compared to reference.  In case of multiple time references this value
    is outcome of RFC 5905 adjustment algorithm.  Ideally offset should be
    close to zero, and it depends about use case how large value is
    acceptable.  For example a typical web server is probably fine if offset
    is about 0.1 or less, but that would not be good enough for mobile phone
    base station operator.

    The node_timex_freq tells amount of adjustment to local clock tick
    frequency.  For example if offset is one second and growing the local
    clock will need instruction to tick quicker.  Number value itself is not
    very important, and occasional small adjustments are fine.  When
    frequency is unusually in stable one can assume quality of time stamps
    will not be accurate to very far in sub second range.  Obviously
    explaining why local clock frequency behaves like a passenger in roller
    coaster is different matter.  Explanations can vary from system load, to
    environmental issues such as a machine being physically too hot.

Rest of the measurements can help when debugging.  If you run a clock server
do probably want to collect and keep track of everything.

Pull-request: https://github.com/prometheus/node_exporter/pull/664
2017-09-19 07:54:06 -07:00
Leonid Evdokimov
c169b4b1c5 Add metrics from SNTPv4 packet to ntp collector & add ntpd sanity check (#655)
* Add metrics from SNTPv4 packet to ntp collector & add ntpd sanity check

1. Checking local clock against remote NTP daemon is bad idea, local
ntpd acting as a  client should do it better and avoid excessive load on
remote NTP server so the collector is refactored to query local NTP
server.

2. Checking local clock against remote one does not check local ntpd
itself. Local ntpd may be down or out of sync due to network issues, but
clock will be OK.

3. Checking NTP server using sanity of it's response is tricky and
depends on ntpd implementation, that's why common `node_ntp_sanity`
variable is exported.

* `govendor add golang.org/x/net/ipv4`, it is dependency of github.com/beevik/ntp

* Update github.com/beevik/ntp to include boring SNTP fix

* Use variable name from RFC5905

* ntp: move code to make export of raw metrics more explicit

* Move NTP math to `github.com/beevik/ntp`

* Make `golint` happy

* Add some brief docs explaining `ntp` #655 and `timex` #664 modules

* ntp: drop XXX comment that got its decision

* ntp: add `_seconds` suffix to relevant metrics

* Better `node_ntp_leap` comment

* s/node_ntp_reftime/node_ntp_reference_timestamp_seconds/ as requested by @discordianfish

* Extract subsystem name to const as suggested by @SuperQ
2017-09-19 10:36:14 +02:00