Node_Exporter/collector/hwmon_linux.go
Paul Gier d0a66c4c40 use sys/unix package instead of syscall (#1340)
According to the golang docs, the syscall package is deprecated.
https://golang.org/pkg/syscall
This updates collectors to use the x/sys/unix package instead.
Also updates the vendored x/sys/unix module to latest.

Signed-off-by: Paul Gier <pgier@redhat.com>
2019-05-10 13:04:06 -05:00

453 lines
14 KiB
Go

// Copyright 2016 The Prometheus Authors
// Licensed under the Apache License, Version 2.0 (the "License");
// you may not use this file except in compliance with the License.
// You may obtain a copy of the License at
//
// http://www.apache.org/licenses/LICENSE-2.0
//
// Unless required by applicable law or agreed to in writing, software
// distributed under the License is distributed on an "AS IS" BASIS,
// WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
// See the License for the specific language governing permissions and
// limitations under the License.
// +build !nohwmon
package collector
import (
"errors"
"io/ioutil"
"os"
"path/filepath"
"regexp"
"strconv"
"strings"
"github.com/prometheus/client_golang/prometheus"
"github.com/prometheus/common/log"
"golang.org/x/sys/unix"
)
var (
hwmonInvalidMetricChars = regexp.MustCompile("[^a-z0-9:_]")
hwmonFilenameFormat = regexp.MustCompile(`^(?P<type>[^0-9]+)(?P<id>[0-9]*)?(_(?P<property>.+))?$`)
hwmonLabelDesc = []string{"chip", "sensor"}
hwmonChipNameLabelDesc = []string{"chip", "chip_name"}
hwmonSensorTypes = []string{
"vrm", "beep_enable", "update_interval", "in", "cpu", "fan",
"pwm", "temp", "curr", "power", "energy", "humidity",
"intrusion",
}
)
func init() {
registerCollector("hwmon", defaultEnabled, NewHwMonCollector)
}
type hwMonCollector struct{}
// NewHwMonCollector returns a new Collector exposing /sys/class/hwmon stats
// (similar to lm-sensors).
func NewHwMonCollector() (Collector, error) {
return &hwMonCollector{}, nil
}
func cleanMetricName(name string) string {
lower := strings.ToLower(name)
replaced := hwmonInvalidMetricChars.ReplaceAllLiteralString(lower, "_")
cleaned := strings.Trim(replaced, "_")
return cleaned
}
func addValueFile(data map[string]map[string]string, sensor string, prop string, file string) {
raw, err := sysReadFile(file)
if err != nil {
return
}
value := strings.Trim(string(raw), "\n")
if _, ok := data[sensor]; !ok {
data[sensor] = make(map[string]string)
}
data[sensor][prop] = value
}
// sysReadFile is a simplified ioutil.ReadFile that invokes syscall.Read directly.
func sysReadFile(file string) ([]byte, error) {
f, err := os.Open(file)
if err != nil {
return nil, err
}
defer f.Close()
// On some machines, hwmon drivers are broken and return EAGAIN. This causes
// Go's ioutil.ReadFile implementation to poll forever.
//
// Since we either want to read data or bail immediately, do the simplest
// possible read using system call directly.
b := make([]byte, 128)
n, err := unix.Read(int(f.Fd()), b)
if err != nil {
return nil, err
}
return b[:n], nil
}
// explodeSensorFilename splits a sensor name into <type><num>_<property>.
func explodeSensorFilename(filename string) (ok bool, sensorType string, sensorNum int, sensorProperty string) {
matches := hwmonFilenameFormat.FindStringSubmatch(filename)
if len(matches) == 0 {
return false, sensorType, sensorNum, sensorProperty
}
for i, match := range hwmonFilenameFormat.SubexpNames() {
if i >= len(matches) {
return true, sensorType, sensorNum, sensorProperty
}
if match == "type" {
sensorType = matches[i]
}
if match == "property" {
sensorProperty = matches[i]
}
if match == "id" && len(matches[i]) > 0 {
if num, err := strconv.Atoi(matches[i]); err == nil {
sensorNum = num
} else {
return false, sensorType, sensorNum, sensorProperty
}
}
}
return true, sensorType, sensorNum, sensorProperty
}
func collectSensorData(dir string, data map[string]map[string]string) error {
sensorFiles, dirError := ioutil.ReadDir(dir)
if dirError != nil {
return dirError
}
for _, file := range sensorFiles {
filename := file.Name()
ok, sensorType, sensorNum, sensorProperty := explodeSensorFilename(filename)
if !ok {
continue
}
for _, t := range hwmonSensorTypes {
if t == sensorType {
addValueFile(data, sensorType+strconv.Itoa(sensorNum), sensorProperty, filepath.Join(dir, file.Name()))
break
}
}
}
return nil
}
func (c *hwMonCollector) updateHwmon(ch chan<- prometheus.Metric, dir string) error {
hwmonName, err := c.hwmonName(dir)
if err != nil {
return err
}
data := make(map[string]map[string]string)
err = collectSensorData(dir, data)
if err != nil {
return err
}
if _, err := os.Stat(filepath.Join(dir, "device")); err == nil {
err := collectSensorData(filepath.Join(dir, "device"), data)
if err != nil {
return err
}
}
hwmonChipName, err := c.hwmonHumanReadableChipName(dir)
if err == nil {
// sensor chip metadata
desc := prometheus.NewDesc(
"node_hwmon_chip_names",
"Annotation metric for human-readable chip names",
hwmonChipNameLabelDesc,
nil,
)
ch <- prometheus.MustNewConstMetric(
desc,
prometheus.GaugeValue,
1.0,
hwmonName,
hwmonChipName,
)
}
// Format all sensors.
for sensor, sensorData := range data {
_, sensorType, _, _ := explodeSensorFilename(sensor)
labels := []string{hwmonName, sensor}
if labelText, ok := sensorData["label"]; ok {
label := cleanMetricName(labelText)
if label != "" {
desc := prometheus.NewDesc("node_hwmon_sensor_label", "Label for given chip and sensor",
[]string{"chip", "sensor", "label"}, nil)
ch <- prometheus.MustNewConstMetric(desc, prometheus.GaugeValue, 1.0, hwmonName, sensor, label)
}
}
if sensorType == "beep_enable" {
value := 0.0
if sensorData[""] == "1" {
value = 1.0
}
metricName := "node_hwmon_beep_enabled"
desc := prometheus.NewDesc(metricName, "Hardware beep enabled", hwmonLabelDesc, nil)
ch <- prometheus.MustNewConstMetric(
desc, prometheus.GaugeValue, value, labels...)
continue
}
if sensorType == "vrm" {
parsedValue, err := strconv.ParseFloat(sensorData[""], 64)
if err != nil {
continue
}
metricName := "node_hwmon_voltage_regulator_version"
desc := prometheus.NewDesc(metricName, "Hardware voltage regulator", hwmonLabelDesc, nil)
ch <- prometheus.MustNewConstMetric(
desc, prometheus.GaugeValue, parsedValue, labels...)
continue
}
if sensorType == "update_interval" {
parsedValue, err := strconv.ParseFloat(sensorData[""], 64)
if err != nil {
continue
}
metricName := "node_hwmon_update_interval_seconds"
desc := prometheus.NewDesc(metricName, "Hardware monitor update interval", hwmonLabelDesc, nil)
ch <- prometheus.MustNewConstMetric(
desc, prometheus.GaugeValue, parsedValue*0.001, labels...)
continue
}
prefix := "node_hwmon_" + sensorType
for element, value := range sensorData {
if element == "label" {
continue
}
name := prefix
if element == "input" {
// input is actually the value
if _, ok := sensorData[""]; ok {
name = name + "_input"
}
} else if element != "" {
name = name + "_" + cleanMetricName(element)
}
parsedValue, err := strconv.ParseFloat(value, 64)
if err != nil {
continue
}
// special elements, fault, alarm & beep should be handed out without units
if element == "fault" || element == "alarm" {
desc := prometheus.NewDesc(name, "Hardware sensor "+element+" status ("+sensorType+")", hwmonLabelDesc, nil)
ch <- prometheus.MustNewConstMetric(desc, prometheus.GaugeValue, parsedValue, labels...)
continue
}
if element == "beep" {
desc := prometheus.NewDesc(name+"_enabled", "Hardware monitor sensor has beeping enabled", hwmonLabelDesc, nil)
ch <- prometheus.MustNewConstMetric(desc, prometheus.GaugeValue, parsedValue, labels...)
continue
}
// everything else should get a unit
if sensorType == "in" || sensorType == "cpu" {
desc := prometheus.NewDesc(name+"_volts", "Hardware monitor for voltage ("+element+")", hwmonLabelDesc, nil)
ch <- prometheus.MustNewConstMetric(
desc, prometheus.GaugeValue, parsedValue*0.001, labels...)
continue
}
if sensorType == "temp" && element != "type" {
if element == "" {
element = "input"
}
desc := prometheus.NewDesc(name+"_celsius", "Hardware monitor for temperature ("+element+")", hwmonLabelDesc, nil)
ch <- prometheus.MustNewConstMetric(
desc, prometheus.GaugeValue, parsedValue*0.001, labels...)
continue
}
if sensorType == "curr" {
desc := prometheus.NewDesc(name+"_amps", "Hardware monitor for current ("+element+")", hwmonLabelDesc, nil)
ch <- prometheus.MustNewConstMetric(
desc, prometheus.GaugeValue, parsedValue*0.001, labels...)
continue
}
if sensorType == "energy" {
desc := prometheus.NewDesc(name+"_joule_total", "Hardware monitor for joules used so far ("+element+")", hwmonLabelDesc, nil)
ch <- prometheus.MustNewConstMetric(
desc, prometheus.CounterValue, parsedValue/1000000.0, labels...)
continue
}
if sensorType == "power" && element == "accuracy" {
desc := prometheus.NewDesc(name, "Hardware monitor power meter accuracy, as a ratio", hwmonLabelDesc, nil)
ch <- prometheus.MustNewConstMetric(
desc, prometheus.GaugeValue, parsedValue/1000000.0, labels...)
continue
}
if sensorType == "power" && (element == "average_interval" || element == "average_interval_min" || element == "average_interval_max") {
desc := prometheus.NewDesc(name+"_seconds", "Hardware monitor power usage update interval ("+element+")", hwmonLabelDesc, nil)
ch <- prometheus.MustNewConstMetric(
desc, prometheus.GaugeValue, parsedValue*0.001, labels...)
continue
}
if sensorType == "power" {
desc := prometheus.NewDesc(name+"_watt", "Hardware monitor for power usage in watts ("+element+")", hwmonLabelDesc, nil)
ch <- prometheus.MustNewConstMetric(
desc, prometheus.GaugeValue, parsedValue/1000000.0, labels...)
continue
}
if sensorType == "humidity" {
desc := prometheus.NewDesc(name, "Hardware monitor for humidity, as a ratio (multiply with 100.0 to get the humidity as a percentage) ("+element+")", hwmonLabelDesc, nil)
ch <- prometheus.MustNewConstMetric(
desc, prometheus.GaugeValue, parsedValue/1000000.0, labels...)
continue
}
if sensorType == "fan" && (element == "input" || element == "min" || element == "max" || element == "target") {
desc := prometheus.NewDesc(name+"_rpm", "Hardware monitor for fan revolutions per minute ("+element+")", hwmonLabelDesc, nil)
ch <- prometheus.MustNewConstMetric(
desc, prometheus.GaugeValue, parsedValue, labels...)
continue
}
// fallback, just dump the metric as is
desc := prometheus.NewDesc(name, "Hardware monitor "+sensorType+" element "+element, hwmonLabelDesc, nil)
ch <- prometheus.MustNewConstMetric(
desc, prometheus.GaugeValue, parsedValue, labels...)
}
}
return nil
}
func (c *hwMonCollector) hwmonName(dir string) (string, error) {
// generate a name for a sensor path
// sensor numbering depends on the order of linux module loading and
// is thus unstable.
// However the path of the device has to be stable:
// - /sys/devices/<bus>/<device>
// Some hardware monitors have a "name" file that exports a human
// readbale name that can be used.
// human readable names would be bat0 or coretemp, while a path string
// could be platform_applesmc.768
// preference 1: construct a name based on device name, always unique
devicePath, devErr := filepath.EvalSymlinks(filepath.Join(dir, "device"))
if devErr == nil {
devPathPrefix, devName := filepath.Split(devicePath)
_, devType := filepath.Split(strings.TrimRight(devPathPrefix, "/"))
cleanDevName := cleanMetricName(devName)
cleanDevType := cleanMetricName(devType)
if cleanDevType != "" && cleanDevName != "" {
return cleanDevType + "_" + cleanDevName, nil
}
if cleanDevName != "" {
return cleanDevName, nil
}
}
// preference 2: is there a name file
sysnameRaw, nameErr := ioutil.ReadFile(filepath.Join(dir, "name"))
if nameErr == nil && string(sysnameRaw) != "" {
cleanName := cleanMetricName(string(sysnameRaw))
if cleanName != "" {
return cleanName, nil
}
}
// it looks bad, name and device don't provide enough information
// return a hwmon[0-9]* name
realDir, err := filepath.EvalSymlinks(dir)
if err != nil {
return "", err
}
// take the last path element, this will be hwmonX
_, name := filepath.Split(realDir)
cleanName := cleanMetricName(name)
if cleanName != "" {
return cleanName, nil
}
return "", errors.New("Could not derive a monitoring name for " + dir)
}
// hwmonHumanReadableChipName is similar to the methods in hwmonName, but with
// different precedences -- we can allow duplicates here.
func (c *hwMonCollector) hwmonHumanReadableChipName(dir string) (string, error) {
sysnameRaw, nameErr := ioutil.ReadFile(filepath.Join(dir, "name"))
if nameErr != nil {
return "", nameErr
}
if string(sysnameRaw) != "" {
cleanName := cleanMetricName(string(sysnameRaw))
if cleanName != "" {
return cleanName, nil
}
}
return "", errors.New("Could not derive a human-readable chip type for " + dir)
}
func (c *hwMonCollector) Update(ch chan<- prometheus.Metric) error {
// Step 1: scan /sys/class/hwmon, resolve all symlinks and call
// updatesHwmon for each folder
hwmonPathName := filepath.Join(sysFilePath("class"), "hwmon")
hwmonFiles, err := ioutil.ReadDir(hwmonPathName)
if err != nil {
if os.IsNotExist(err) {
log.Debug("hwmon collector metrics are not available for this system")
return nil
}
return err
}
for _, hwDir := range hwmonFiles {
hwmonXPathName := filepath.Join(hwmonPathName, hwDir.Name())
if hwDir.Mode()&os.ModeSymlink > 0 {
hwDir, err = os.Stat(hwmonXPathName)
if err != nil {
continue
}
}
if !hwDir.IsDir() {
continue
}
if lastErr := c.updateHwmon(ch, hwmonXPathName); lastErr != nil {
err = lastErr
}
}
return err
}