In some cases the file might be called "temp" instead of the usual format "temp<index>_<item>" as described in the kernel docs: https://www.kernel.org/doc/Documentation/hwmon/sysfs-interface In this case, treat this as an _input file containing the current temperature reading. Fixes #1122 Signed-off-by: Paul Gier <pgier@redhat.com>
454 lines
14 KiB
Go
454 lines
14 KiB
Go
// Copyright 2016 The Prometheus Authors
|
|
// Licensed under the Apache License, Version 2.0 (the "License");
|
|
// you may not use this file except in compliance with the License.
|
|
// You may obtain a copy of the License at
|
|
//
|
|
// http://www.apache.org/licenses/LICENSE-2.0
|
|
//
|
|
// Unless required by applicable law or agreed to in writing, software
|
|
// distributed under the License is distributed on an "AS IS" BASIS,
|
|
// WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
|
|
// See the License for the specific language governing permissions and
|
|
// limitations under the License.
|
|
|
|
// +build !nohwmon
|
|
|
|
package collector
|
|
|
|
import (
|
|
"errors"
|
|
"io/ioutil"
|
|
"os"
|
|
"path"
|
|
"path/filepath"
|
|
"regexp"
|
|
"strconv"
|
|
"strings"
|
|
"syscall"
|
|
|
|
"github.com/prometheus/client_golang/prometheus"
|
|
"github.com/prometheus/common/log"
|
|
)
|
|
|
|
var (
|
|
hwmonInvalidMetricChars = regexp.MustCompile("[^a-z0-9:_]")
|
|
hwmonFilenameFormat = regexp.MustCompile(`^(?P<type>[^0-9]+)(?P<id>[0-9]*)?(_(?P<property>.+))?$`)
|
|
hwmonLabelDesc = []string{"chip", "sensor"}
|
|
hwmonChipNameLabelDesc = []string{"chip", "chip_name"}
|
|
hwmonSensorTypes = []string{
|
|
"vrm", "beep_enable", "update_interval", "in", "cpu", "fan",
|
|
"pwm", "temp", "curr", "power", "energy", "humidity",
|
|
"intrusion",
|
|
}
|
|
)
|
|
|
|
func init() {
|
|
registerCollector("hwmon", defaultEnabled, NewHwMonCollector)
|
|
}
|
|
|
|
type hwMonCollector struct{}
|
|
|
|
// NewHwMonCollector returns a new Collector exposing /sys/class/hwmon stats
|
|
// (similar to lm-sensors).
|
|
func NewHwMonCollector() (Collector, error) {
|
|
return &hwMonCollector{}, nil
|
|
}
|
|
|
|
func cleanMetricName(name string) string {
|
|
lower := strings.ToLower(name)
|
|
replaced := hwmonInvalidMetricChars.ReplaceAllLiteralString(lower, "_")
|
|
cleaned := strings.Trim(replaced, "_")
|
|
return cleaned
|
|
}
|
|
|
|
func addValueFile(data map[string]map[string]string, sensor string, prop string, file string) {
|
|
raw, err := sysReadFile(file)
|
|
if err != nil {
|
|
return
|
|
}
|
|
value := strings.Trim(string(raw), "\n")
|
|
|
|
if _, ok := data[sensor]; !ok {
|
|
data[sensor] = make(map[string]string)
|
|
}
|
|
|
|
data[sensor][prop] = value
|
|
}
|
|
|
|
// sysReadFile is a simplified ioutil.ReadFile that invokes syscall.Read directly.
|
|
func sysReadFile(file string) ([]byte, error) {
|
|
f, err := os.Open(file)
|
|
if err != nil {
|
|
return nil, err
|
|
}
|
|
defer f.Close()
|
|
|
|
// On some machines, hwmon drivers are broken and return EAGAIN. This causes
|
|
// Go's ioutil.ReadFile implementation to poll forever.
|
|
//
|
|
// Since we either want to read data or bail immediately, do the simplest
|
|
// possible read using syscall directly.
|
|
b := make([]byte, 128)
|
|
n, err := syscall.Read(int(f.Fd()), b)
|
|
if err != nil {
|
|
return nil, err
|
|
}
|
|
|
|
return b[:n], nil
|
|
}
|
|
|
|
// explodeSensorFilename splits a sensor name into <type><num>_<property>.
|
|
func explodeSensorFilename(filename string) (ok bool, sensorType string, sensorNum int, sensorProperty string) {
|
|
matches := hwmonFilenameFormat.FindStringSubmatch(filename)
|
|
if len(matches) == 0 {
|
|
return false, sensorType, sensorNum, sensorProperty
|
|
}
|
|
for i, match := range hwmonFilenameFormat.SubexpNames() {
|
|
if i >= len(matches) {
|
|
return true, sensorType, sensorNum, sensorProperty
|
|
}
|
|
if match == "type" {
|
|
sensorType = matches[i]
|
|
}
|
|
if match == "property" {
|
|
sensorProperty = matches[i]
|
|
}
|
|
if match == "id" && len(matches[i]) > 0 {
|
|
if num, err := strconv.Atoi(matches[i]); err == nil {
|
|
sensorNum = num
|
|
} else {
|
|
return false, sensorType, sensorNum, sensorProperty
|
|
}
|
|
}
|
|
}
|
|
return true, sensorType, sensorNum, sensorProperty
|
|
}
|
|
|
|
func collectSensorData(dir string, data map[string]map[string]string) error {
|
|
sensorFiles, dirError := ioutil.ReadDir(dir)
|
|
if dirError != nil {
|
|
return dirError
|
|
}
|
|
for _, file := range sensorFiles {
|
|
filename := file.Name()
|
|
ok, sensorType, sensorNum, sensorProperty := explodeSensorFilename(filename)
|
|
if !ok {
|
|
continue
|
|
}
|
|
|
|
for _, t := range hwmonSensorTypes {
|
|
if t == sensorType {
|
|
addValueFile(data, sensorType+strconv.Itoa(sensorNum), sensorProperty, path.Join(dir, file.Name()))
|
|
break
|
|
}
|
|
}
|
|
}
|
|
return nil
|
|
}
|
|
|
|
func (c *hwMonCollector) updateHwmon(ch chan<- prometheus.Metric, dir string) error {
|
|
hwmonName, err := c.hwmonName(dir)
|
|
if err != nil {
|
|
return err
|
|
}
|
|
|
|
data := make(map[string]map[string]string)
|
|
err = collectSensorData(dir, data)
|
|
if err != nil {
|
|
return err
|
|
}
|
|
if _, err := os.Stat(path.Join(dir, "device")); err == nil {
|
|
err := collectSensorData(path.Join(dir, "device"), data)
|
|
if err != nil {
|
|
return err
|
|
}
|
|
}
|
|
|
|
hwmonChipName, err := c.hwmonHumanReadableChipName(dir)
|
|
if err == nil {
|
|
// sensor chip metadata
|
|
desc := prometheus.NewDesc(
|
|
"node_hwmon_chip_names",
|
|
"Annotation metric for human-readable chip names",
|
|
hwmonChipNameLabelDesc,
|
|
nil,
|
|
)
|
|
|
|
ch <- prometheus.MustNewConstMetric(
|
|
desc,
|
|
prometheus.GaugeValue,
|
|
1.0,
|
|
hwmonName,
|
|
hwmonChipName,
|
|
)
|
|
}
|
|
|
|
// Format all sensors.
|
|
for sensor, sensorData := range data {
|
|
|
|
_, sensorType, _, _ := explodeSensorFilename(sensor)
|
|
|
|
labels := []string{hwmonName, sensor}
|
|
if labelText, ok := sensorData["label"]; ok {
|
|
label := cleanMetricName(labelText)
|
|
if label != "" {
|
|
desc := prometheus.NewDesc("node_hwmon_sensor_label", "Label for given chip and sensor",
|
|
[]string{"chip", "sensor", "label"}, nil)
|
|
ch <- prometheus.MustNewConstMetric(desc, prometheus.GaugeValue, 1.0, hwmonName, sensor, label)
|
|
}
|
|
}
|
|
|
|
if sensorType == "beep_enable" {
|
|
value := 0.0
|
|
if sensorData[""] == "1" {
|
|
value = 1.0
|
|
}
|
|
metricName := "node_hwmon_beep_enabled"
|
|
desc := prometheus.NewDesc(metricName, "Hardware beep enabled", hwmonLabelDesc, nil)
|
|
ch <- prometheus.MustNewConstMetric(
|
|
desc, prometheus.GaugeValue, value, labels...)
|
|
continue
|
|
}
|
|
if sensorType == "vrm" {
|
|
parsedValue, err := strconv.ParseFloat(sensorData[""], 64)
|
|
if err != nil {
|
|
continue
|
|
}
|
|
metricName := "node_hwmon_voltage_regulator_version"
|
|
desc := prometheus.NewDesc(metricName, "Hardware voltage regulator", hwmonLabelDesc, nil)
|
|
ch <- prometheus.MustNewConstMetric(
|
|
desc, prometheus.GaugeValue, parsedValue, labels...)
|
|
continue
|
|
}
|
|
if sensorType == "update_interval" {
|
|
parsedValue, err := strconv.ParseFloat(sensorData[""], 64)
|
|
if err != nil {
|
|
continue
|
|
}
|
|
metricName := "node_hwmon_update_interval_seconds"
|
|
desc := prometheus.NewDesc(metricName, "Hardware monitor update interval", hwmonLabelDesc, nil)
|
|
ch <- prometheus.MustNewConstMetric(
|
|
desc, prometheus.GaugeValue, parsedValue*0.001, labels...)
|
|
continue
|
|
}
|
|
|
|
prefix := "node_hwmon_" + sensorType
|
|
|
|
for element, value := range sensorData {
|
|
|
|
if element == "label" {
|
|
continue
|
|
}
|
|
|
|
name := prefix
|
|
if element == "input" {
|
|
// input is actually the value
|
|
if _, ok := sensorData[""]; ok {
|
|
name = name + "_input"
|
|
}
|
|
} else if element != "" {
|
|
name = name + "_" + cleanMetricName(element)
|
|
}
|
|
parsedValue, err := strconv.ParseFloat(value, 64)
|
|
if err != nil {
|
|
continue
|
|
}
|
|
|
|
// special elements, fault, alarm & beep should be handed out without units
|
|
if element == "fault" || element == "alarm" {
|
|
desc := prometheus.NewDesc(name, "Hardware sensor "+element+" status ("+sensorType+")", hwmonLabelDesc, nil)
|
|
ch <- prometheus.MustNewConstMetric(desc, prometheus.GaugeValue, parsedValue, labels...)
|
|
continue
|
|
}
|
|
if element == "beep" {
|
|
desc := prometheus.NewDesc(name+"_enabled", "Hardware monitor sensor has beeping enabled", hwmonLabelDesc, nil)
|
|
ch <- prometheus.MustNewConstMetric(desc, prometheus.GaugeValue, parsedValue, labels...)
|
|
continue
|
|
}
|
|
|
|
// everything else should get a unit
|
|
if sensorType == "in" || sensorType == "cpu" {
|
|
desc := prometheus.NewDesc(name+"_volts", "Hardware monitor for voltage ("+element+")", hwmonLabelDesc, nil)
|
|
ch <- prometheus.MustNewConstMetric(
|
|
desc, prometheus.GaugeValue, parsedValue*0.001, labels...)
|
|
continue
|
|
}
|
|
if sensorType == "temp" && element != "type" {
|
|
if element == "" {
|
|
element = "input"
|
|
}
|
|
desc := prometheus.NewDesc(name+"_celsius", "Hardware monitor for temperature ("+element+")", hwmonLabelDesc, nil)
|
|
ch <- prometheus.MustNewConstMetric(
|
|
desc, prometheus.GaugeValue, parsedValue*0.001, labels...)
|
|
continue
|
|
}
|
|
if sensorType == "curr" {
|
|
desc := prometheus.NewDesc(name+"_amps", "Hardware monitor for current ("+element+")", hwmonLabelDesc, nil)
|
|
ch <- prometheus.MustNewConstMetric(
|
|
desc, prometheus.GaugeValue, parsedValue*0.001, labels...)
|
|
continue
|
|
}
|
|
if sensorType == "energy" {
|
|
desc := prometheus.NewDesc(name+"_joule_total", "Hardware monitor for joules used so far ("+element+")", hwmonLabelDesc, nil)
|
|
ch <- prometheus.MustNewConstMetric(
|
|
desc, prometheus.CounterValue, parsedValue/1000000.0, labels...)
|
|
continue
|
|
}
|
|
if sensorType == "power" && element == "accuracy" {
|
|
desc := prometheus.NewDesc(name, "Hardware monitor power meter accuracy, as a ratio", hwmonLabelDesc, nil)
|
|
ch <- prometheus.MustNewConstMetric(
|
|
desc, prometheus.GaugeValue, parsedValue/1000000.0, labels...)
|
|
continue
|
|
}
|
|
if sensorType == "power" && (element == "average_interval" || element == "average_interval_min" || element == "average_interval_max") {
|
|
desc := prometheus.NewDesc(name+"_seconds", "Hardware monitor power usage update interval ("+element+")", hwmonLabelDesc, nil)
|
|
ch <- prometheus.MustNewConstMetric(
|
|
desc, prometheus.GaugeValue, parsedValue*0.001, labels...)
|
|
continue
|
|
}
|
|
if sensorType == "power" {
|
|
desc := prometheus.NewDesc(name+"_watt", "Hardware monitor for power usage in watts ("+element+")", hwmonLabelDesc, nil)
|
|
ch <- prometheus.MustNewConstMetric(
|
|
desc, prometheus.GaugeValue, parsedValue/1000000.0, labels...)
|
|
continue
|
|
}
|
|
|
|
if sensorType == "humidity" {
|
|
desc := prometheus.NewDesc(name, "Hardware monitor for humidity, as a ratio (multiply with 100.0 to get the humidity as a percentage) ("+element+")", hwmonLabelDesc, nil)
|
|
ch <- prometheus.MustNewConstMetric(
|
|
desc, prometheus.GaugeValue, parsedValue/1000000.0, labels...)
|
|
continue
|
|
}
|
|
|
|
if sensorType == "fan" && (element == "input" || element == "min" || element == "max" || element == "target") {
|
|
desc := prometheus.NewDesc(name+"_rpm", "Hardware monitor for fan revolutions per minute ("+element+")", hwmonLabelDesc, nil)
|
|
ch <- prometheus.MustNewConstMetric(
|
|
desc, prometheus.GaugeValue, parsedValue, labels...)
|
|
continue
|
|
}
|
|
|
|
// fallback, just dump the metric as is
|
|
|
|
desc := prometheus.NewDesc(name, "Hardware monitor "+sensorType+" element "+element, hwmonLabelDesc, nil)
|
|
ch <- prometheus.MustNewConstMetric(
|
|
desc, prometheus.GaugeValue, parsedValue, labels...)
|
|
}
|
|
}
|
|
|
|
return nil
|
|
}
|
|
|
|
func (c *hwMonCollector) hwmonName(dir string) (string, error) {
|
|
// generate a name for a sensor path
|
|
|
|
// sensor numbering depends on the order of linux module loading and
|
|
// is thus unstable.
|
|
// However the path of the device has to be stable:
|
|
// - /sys/devices/<bus>/<device>
|
|
// Some hardware monitors have a "name" file that exports a human
|
|
// readbale name that can be used.
|
|
|
|
// human readable names would be bat0 or coretemp, while a path string
|
|
// could be platform_applesmc.768
|
|
|
|
// preference 1: construct a name based on device name, always unique
|
|
|
|
devicePath, devErr := filepath.EvalSymlinks(path.Join(dir, "device"))
|
|
if devErr == nil {
|
|
devPathPrefix, devName := path.Split(devicePath)
|
|
_, devType := path.Split(strings.TrimRight(devPathPrefix, "/"))
|
|
|
|
cleanDevName := cleanMetricName(devName)
|
|
cleanDevType := cleanMetricName(devType)
|
|
|
|
if cleanDevType != "" && cleanDevName != "" {
|
|
return cleanDevType + "_" + cleanDevName, nil
|
|
}
|
|
|
|
if cleanDevName != "" {
|
|
return cleanDevName, nil
|
|
}
|
|
}
|
|
|
|
// preference 2: is there a name file
|
|
sysnameRaw, nameErr := ioutil.ReadFile(path.Join(dir, "name"))
|
|
if nameErr == nil && string(sysnameRaw) != "" {
|
|
cleanName := cleanMetricName(string(sysnameRaw))
|
|
if cleanName != "" {
|
|
return cleanName, nil
|
|
}
|
|
}
|
|
|
|
// it looks bad, name and device don't provide enough information
|
|
// return a hwmon[0-9]* name
|
|
|
|
realDir, err := filepath.EvalSymlinks(dir)
|
|
if err != nil {
|
|
return "", err
|
|
}
|
|
|
|
// take the last path element, this will be hwmonX
|
|
_, name := path.Split(realDir)
|
|
cleanName := cleanMetricName(name)
|
|
if cleanName != "" {
|
|
return cleanName, nil
|
|
}
|
|
return "", errors.New("Could not derive a monitoring name for " + dir)
|
|
}
|
|
|
|
// hwmonHumanReadableChipName is similar to the methods in hwmonName, but with
|
|
// different precedences -- we can allow duplicates here.
|
|
func (c *hwMonCollector) hwmonHumanReadableChipName(dir string) (string, error) {
|
|
sysnameRaw, nameErr := ioutil.ReadFile(path.Join(dir, "name"))
|
|
if nameErr != nil {
|
|
return "", nameErr
|
|
}
|
|
|
|
if string(sysnameRaw) != "" {
|
|
cleanName := cleanMetricName(string(sysnameRaw))
|
|
if cleanName != "" {
|
|
return cleanName, nil
|
|
}
|
|
}
|
|
|
|
return "", errors.New("Could not derive a human-readable chip type for " + dir)
|
|
}
|
|
|
|
func (c *hwMonCollector) Update(ch chan<- prometheus.Metric) error {
|
|
// Step 1: scan /sys/class/hwmon, resolve all symlinks and call
|
|
// updatesHwmon for each folder
|
|
|
|
hwmonPathName := path.Join(sysFilePath("class"), "hwmon")
|
|
|
|
hwmonFiles, err := ioutil.ReadDir(hwmonPathName)
|
|
if err != nil {
|
|
if os.IsNotExist(err) {
|
|
log.Debug("hwmon collector metrics are not available for this system")
|
|
return nil
|
|
}
|
|
|
|
return err
|
|
}
|
|
|
|
for _, hwDir := range hwmonFiles {
|
|
hwmonXPathName := path.Join(hwmonPathName, hwDir.Name())
|
|
|
|
if hwDir.Mode()&os.ModeSymlink > 0 {
|
|
hwDir, err = os.Stat(hwmonXPathName)
|
|
if err != nil {
|
|
continue
|
|
}
|
|
}
|
|
|
|
if !hwDir.IsDir() {
|
|
continue
|
|
}
|
|
|
|
if lastErr := c.updateHwmon(ch, hwmonXPathName); lastErr != nil {
|
|
err = lastErr
|
|
}
|
|
}
|
|
|
|
return err
|
|
}
|