mirror of
https://github.com/prometheus/node_exporter.git
synced 2024-11-27 02:53:02 +01:00
acb36765b4
* Update Go to 1.22. * Update Go modules. * Use new version collector. * Use standard library slices package. Signed-off-by: Ben Kochie <superq@gmail.com>
458 lines
16 KiB
Go
458 lines
16 KiB
Go
// Copyright 2015 The Prometheus Authors
|
|
// Licensed under the Apache License, Version 2.0 (the "License");
|
|
// you may not use this file except in compliance with the License.
|
|
// You may obtain a copy of the License at
|
|
//
|
|
// http://www.apache.org/licenses/LICENSE-2.0
|
|
//
|
|
// Unless required by applicable law or agreed to in writing, software
|
|
// distributed under the License is distributed on an "AS IS" BASIS,
|
|
// WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
|
|
// See the License for the specific language governing permissions and
|
|
// limitations under the License.
|
|
|
|
//go:build !nocpu
|
|
// +build !nocpu
|
|
|
|
package collector
|
|
|
|
import (
|
|
"fmt"
|
|
"os"
|
|
"path/filepath"
|
|
"regexp"
|
|
"slices"
|
|
"strconv"
|
|
"sync"
|
|
|
|
"github.com/alecthomas/kingpin/v2"
|
|
"github.com/go-kit/log"
|
|
"github.com/go-kit/log/level"
|
|
"github.com/prometheus/client_golang/prometheus"
|
|
"github.com/prometheus/procfs"
|
|
"github.com/prometheus/procfs/sysfs"
|
|
"golang.org/x/exp/maps"
|
|
)
|
|
|
|
type cpuCollector struct {
|
|
fs procfs.FS
|
|
cpu *prometheus.Desc
|
|
cpuInfo *prometheus.Desc
|
|
cpuFrequencyHz *prometheus.Desc
|
|
cpuFlagsInfo *prometheus.Desc
|
|
cpuBugsInfo *prometheus.Desc
|
|
cpuGuest *prometheus.Desc
|
|
cpuCoreThrottle *prometheus.Desc
|
|
cpuPackageThrottle *prometheus.Desc
|
|
cpuIsolated *prometheus.Desc
|
|
logger log.Logger
|
|
cpuStats map[int64]procfs.CPUStat
|
|
cpuStatsMutex sync.Mutex
|
|
isolatedCpus []uint16
|
|
|
|
cpuFlagsIncludeRegexp *regexp.Regexp
|
|
cpuBugsIncludeRegexp *regexp.Regexp
|
|
}
|
|
|
|
// Idle jump back limit in seconds.
|
|
const jumpBackSeconds = 3.0
|
|
|
|
var (
|
|
enableCPUGuest = kingpin.Flag("collector.cpu.guest", "Enables metric node_cpu_guest_seconds_total").Default("true").Bool()
|
|
enableCPUInfo = kingpin.Flag("collector.cpu.info", "Enables metric cpu_info").Bool()
|
|
flagsInclude = kingpin.Flag("collector.cpu.info.flags-include", "Filter the `flags` field in cpuInfo with a value that must be a regular expression").String()
|
|
bugsInclude = kingpin.Flag("collector.cpu.info.bugs-include", "Filter the `bugs` field in cpuInfo with a value that must be a regular expression").String()
|
|
jumpBackDebugMessage = fmt.Sprintf("CPU Idle counter jumped backwards more than %f seconds, possible hotplug event, resetting CPU stats", jumpBackSeconds)
|
|
)
|
|
|
|
func init() {
|
|
registerCollector("cpu", defaultEnabled, NewCPUCollector)
|
|
}
|
|
|
|
// NewCPUCollector returns a new Collector exposing kernel/system statistics.
|
|
func NewCPUCollector(logger log.Logger) (Collector, error) {
|
|
fs, err := procfs.NewFS(*procPath)
|
|
if err != nil {
|
|
return nil, fmt.Errorf("failed to open procfs: %w", err)
|
|
}
|
|
|
|
sysfs, err := sysfs.NewFS(*sysPath)
|
|
if err != nil {
|
|
return nil, fmt.Errorf("failed to open sysfs: %w", err)
|
|
}
|
|
|
|
isolcpus, err := sysfs.IsolatedCPUs()
|
|
if err != nil {
|
|
if !os.IsNotExist(err) {
|
|
return nil, fmt.Errorf("Unable to get isolated cpus: %w", err)
|
|
}
|
|
level.Debug(logger).Log("msg", "Could not open isolated file", "error", err)
|
|
}
|
|
|
|
c := &cpuCollector{
|
|
fs: fs,
|
|
cpu: nodeCPUSecondsDesc,
|
|
cpuInfo: prometheus.NewDesc(
|
|
prometheus.BuildFQName(namespace, cpuCollectorSubsystem, "info"),
|
|
"CPU information from /proc/cpuinfo.",
|
|
[]string{"package", "core", "cpu", "vendor", "family", "model", "model_name", "microcode", "stepping", "cachesize"}, nil,
|
|
),
|
|
cpuFrequencyHz: prometheus.NewDesc(
|
|
prometheus.BuildFQName(namespace, cpuCollectorSubsystem, "frequency_hertz"),
|
|
"CPU frequency in hertz from /proc/cpuinfo.",
|
|
[]string{"package", "core", "cpu"}, nil,
|
|
),
|
|
cpuFlagsInfo: prometheus.NewDesc(
|
|
prometheus.BuildFQName(namespace, cpuCollectorSubsystem, "flag_info"),
|
|
"The `flags` field of CPU information from /proc/cpuinfo taken from the first core.",
|
|
[]string{"flag"}, nil,
|
|
),
|
|
cpuBugsInfo: prometheus.NewDesc(
|
|
prometheus.BuildFQName(namespace, cpuCollectorSubsystem, "bug_info"),
|
|
"The `bugs` field of CPU information from /proc/cpuinfo taken from the first core.",
|
|
[]string{"bug"}, nil,
|
|
),
|
|
cpuGuest: prometheus.NewDesc(
|
|
prometheus.BuildFQName(namespace, cpuCollectorSubsystem, "guest_seconds_total"),
|
|
"Seconds the CPUs spent in guests (VMs) for each mode.",
|
|
[]string{"cpu", "mode"}, nil,
|
|
),
|
|
cpuCoreThrottle: prometheus.NewDesc(
|
|
prometheus.BuildFQName(namespace, cpuCollectorSubsystem, "core_throttles_total"),
|
|
"Number of times this CPU core has been throttled.",
|
|
[]string{"package", "core"}, nil,
|
|
),
|
|
cpuPackageThrottle: prometheus.NewDesc(
|
|
prometheus.BuildFQName(namespace, cpuCollectorSubsystem, "package_throttles_total"),
|
|
"Number of times this CPU package has been throttled.",
|
|
[]string{"package"}, nil,
|
|
),
|
|
cpuIsolated: prometheus.NewDesc(
|
|
prometheus.BuildFQName(namespace, cpuCollectorSubsystem, "isolated"),
|
|
"Whether each core is isolated, information from /sys/devices/system/cpu/isolated.",
|
|
[]string{"cpu"}, nil,
|
|
),
|
|
logger: logger,
|
|
isolatedCpus: isolcpus,
|
|
cpuStats: make(map[int64]procfs.CPUStat),
|
|
}
|
|
err = c.compileIncludeFlags(flagsInclude, bugsInclude)
|
|
if err != nil {
|
|
return nil, fmt.Errorf("fail to compile --collector.cpu.info.flags-include and --collector.cpu.info.bugs-include, the values of them must be regular expressions: %w", err)
|
|
}
|
|
return c, nil
|
|
}
|
|
|
|
func (c *cpuCollector) compileIncludeFlags(flagsIncludeFlag, bugsIncludeFlag *string) error {
|
|
if (*flagsIncludeFlag != "" || *bugsIncludeFlag != "") && !*enableCPUInfo {
|
|
*enableCPUInfo = true
|
|
level.Info(c.logger).Log("msg", "--collector.cpu.info has been set to `true` because you set the following flags, like --collector.cpu.info.flags-include and --collector.cpu.info.bugs-include")
|
|
}
|
|
|
|
var err error
|
|
if *flagsIncludeFlag != "" {
|
|
c.cpuFlagsIncludeRegexp, err = regexp.Compile(*flagsIncludeFlag)
|
|
if err != nil {
|
|
return err
|
|
}
|
|
}
|
|
if *bugsIncludeFlag != "" {
|
|
c.cpuBugsIncludeRegexp, err = regexp.Compile(*bugsIncludeFlag)
|
|
if err != nil {
|
|
return err
|
|
}
|
|
}
|
|
return nil
|
|
}
|
|
|
|
// Update implements Collector and exposes cpu related metrics from /proc/stat and /sys/.../cpu/.
|
|
func (c *cpuCollector) Update(ch chan<- prometheus.Metric) error {
|
|
if *enableCPUInfo {
|
|
if err := c.updateInfo(ch); err != nil {
|
|
return err
|
|
}
|
|
}
|
|
if err := c.updateStat(ch); err != nil {
|
|
return err
|
|
}
|
|
if c.isolatedCpus != nil {
|
|
c.updateIsolated(ch)
|
|
}
|
|
return c.updateThermalThrottle(ch)
|
|
}
|
|
|
|
// updateInfo reads /proc/cpuinfo
|
|
func (c *cpuCollector) updateInfo(ch chan<- prometheus.Metric) error {
|
|
info, err := c.fs.CPUInfo()
|
|
if err != nil {
|
|
return err
|
|
}
|
|
for _, cpu := range info {
|
|
ch <- prometheus.MustNewConstMetric(c.cpuInfo,
|
|
prometheus.GaugeValue,
|
|
1,
|
|
cpu.PhysicalID,
|
|
cpu.CoreID,
|
|
strconv.Itoa(int(cpu.Processor)),
|
|
cpu.VendorID,
|
|
cpu.CPUFamily,
|
|
cpu.Model,
|
|
cpu.ModelName,
|
|
cpu.Microcode,
|
|
cpu.Stepping,
|
|
cpu.CacheSize)
|
|
}
|
|
|
|
cpuFreqEnabled, ok := collectorState["cpufreq"]
|
|
if !ok || cpuFreqEnabled == nil {
|
|
level.Debug(c.logger).Log("msg", "cpufreq key missing or nil value in collectorState map")
|
|
} else if !*cpuFreqEnabled {
|
|
for _, cpu := range info {
|
|
ch <- prometheus.MustNewConstMetric(c.cpuFrequencyHz,
|
|
prometheus.GaugeValue,
|
|
cpu.CPUMHz*1e6,
|
|
cpu.PhysicalID,
|
|
cpu.CoreID,
|
|
strconv.Itoa(int(cpu.Processor)))
|
|
}
|
|
}
|
|
|
|
if len(info) != 0 {
|
|
cpu := info[0]
|
|
if err := updateFieldInfo(cpu.Flags, c.cpuFlagsIncludeRegexp, c.cpuFlagsInfo, ch); err != nil {
|
|
return err
|
|
}
|
|
if err := updateFieldInfo(cpu.Bugs, c.cpuBugsIncludeRegexp, c.cpuBugsInfo, ch); err != nil {
|
|
return err
|
|
}
|
|
}
|
|
|
|
return nil
|
|
}
|
|
|
|
func updateFieldInfo(valueList []string, filter *regexp.Regexp, desc *prometheus.Desc, ch chan<- prometheus.Metric) error {
|
|
if filter == nil {
|
|
return nil
|
|
}
|
|
|
|
for _, val := range valueList {
|
|
if !filter.MatchString(val) {
|
|
continue
|
|
}
|
|
ch <- prometheus.MustNewConstMetric(desc,
|
|
prometheus.GaugeValue,
|
|
1,
|
|
val,
|
|
)
|
|
}
|
|
return nil
|
|
}
|
|
|
|
// updateThermalThrottle reads /sys/devices/system/cpu/cpu* and expose thermal throttle statistics.
|
|
func (c *cpuCollector) updateThermalThrottle(ch chan<- prometheus.Metric) error {
|
|
cpus, err := filepath.Glob(sysFilePath("devices/system/cpu/cpu[0-9]*"))
|
|
if err != nil {
|
|
return err
|
|
}
|
|
|
|
packageThrottles := make(map[uint64]uint64)
|
|
packageCoreThrottles := make(map[uint64]map[uint64]uint64)
|
|
|
|
// cpu loop
|
|
for _, cpu := range cpus {
|
|
// See
|
|
// https://www.kernel.org/doc/Documentation/x86/topology.txt
|
|
// https://www.kernel.org/doc/Documentation/cputopology.txt
|
|
// https://www.kernel.org/doc/Documentation/ABI/testing/sysfs-devices-system-cpu
|
|
var err error
|
|
var physicalPackageID, coreID uint64
|
|
|
|
// topology/physical_package_id
|
|
if physicalPackageID, err = readUintFromFile(filepath.Join(cpu, "topology", "physical_package_id")); err != nil {
|
|
level.Debug(c.logger).Log("msg", "CPU is missing physical_package_id", "cpu", cpu)
|
|
continue
|
|
}
|
|
// topology/core_id
|
|
if coreID, err = readUintFromFile(filepath.Join(cpu, "topology", "core_id")); err != nil {
|
|
level.Debug(c.logger).Log("msg", "CPU is missing core_id", "cpu", cpu)
|
|
continue
|
|
}
|
|
|
|
// metric node_cpu_core_throttles_total
|
|
//
|
|
// We process this metric before the package throttles as there
|
|
// are CPU+kernel combinations that only present core throttles
|
|
// but no package throttles.
|
|
// Seen e.g. on an Intel Xeon E5472 system with RHEL 6.9 kernel.
|
|
if _, present := packageCoreThrottles[physicalPackageID]; !present {
|
|
packageCoreThrottles[physicalPackageID] = make(map[uint64]uint64)
|
|
}
|
|
if _, present := packageCoreThrottles[physicalPackageID][coreID]; !present {
|
|
// Read thermal_throttle/core_throttle_count only once
|
|
if coreThrottleCount, err := readUintFromFile(filepath.Join(cpu, "thermal_throttle", "core_throttle_count")); err == nil {
|
|
packageCoreThrottles[physicalPackageID][coreID] = coreThrottleCount
|
|
} else {
|
|
level.Debug(c.logger).Log("msg", "CPU is missing core_throttle_count", "cpu", cpu)
|
|
}
|
|
}
|
|
|
|
// metric node_cpu_package_throttles_total
|
|
if _, present := packageThrottles[physicalPackageID]; !present {
|
|
// Read thermal_throttle/package_throttle_count only once
|
|
if packageThrottleCount, err := readUintFromFile(filepath.Join(cpu, "thermal_throttle", "package_throttle_count")); err == nil {
|
|
packageThrottles[physicalPackageID] = packageThrottleCount
|
|
} else {
|
|
level.Debug(c.logger).Log("msg", "CPU is missing package_throttle_count", "cpu", cpu)
|
|
}
|
|
}
|
|
}
|
|
|
|
for physicalPackageID, packageThrottleCount := range packageThrottles {
|
|
ch <- prometheus.MustNewConstMetric(c.cpuPackageThrottle,
|
|
prometheus.CounterValue,
|
|
float64(packageThrottleCount),
|
|
strconv.FormatUint(physicalPackageID, 10))
|
|
}
|
|
|
|
for physicalPackageID, coreMap := range packageCoreThrottles {
|
|
for coreID, coreThrottleCount := range coreMap {
|
|
ch <- prometheus.MustNewConstMetric(c.cpuCoreThrottle,
|
|
prometheus.CounterValue,
|
|
float64(coreThrottleCount),
|
|
strconv.FormatUint(physicalPackageID, 10),
|
|
strconv.FormatUint(coreID, 10))
|
|
}
|
|
}
|
|
return nil
|
|
}
|
|
|
|
// updateIsolated reads /sys/devices/system/cpu/isolated through sysfs and exports isolation level metrics.
|
|
func (c *cpuCollector) updateIsolated(ch chan<- prometheus.Metric) {
|
|
for _, cpu := range c.isolatedCpus {
|
|
cpuNum := strconv.Itoa(int(cpu))
|
|
ch <- prometheus.MustNewConstMetric(c.cpuIsolated, prometheus.GaugeValue, 1.0, cpuNum)
|
|
}
|
|
}
|
|
|
|
// updateStat reads /proc/stat through procfs and exports CPU-related metrics.
|
|
func (c *cpuCollector) updateStat(ch chan<- prometheus.Metric) error {
|
|
stats, err := c.fs.Stat()
|
|
if err != nil {
|
|
return err
|
|
}
|
|
|
|
c.updateCPUStats(stats.CPU)
|
|
|
|
// Acquire a lock to read the stats.
|
|
c.cpuStatsMutex.Lock()
|
|
defer c.cpuStatsMutex.Unlock()
|
|
for cpuID, cpuStat := range c.cpuStats {
|
|
cpuNum := strconv.Itoa(int(cpuID))
|
|
ch <- prometheus.MustNewConstMetric(c.cpu, prometheus.CounterValue, cpuStat.User, cpuNum, "user")
|
|
ch <- prometheus.MustNewConstMetric(c.cpu, prometheus.CounterValue, cpuStat.Nice, cpuNum, "nice")
|
|
ch <- prometheus.MustNewConstMetric(c.cpu, prometheus.CounterValue, cpuStat.System, cpuNum, "system")
|
|
ch <- prometheus.MustNewConstMetric(c.cpu, prometheus.CounterValue, cpuStat.Idle, cpuNum, "idle")
|
|
ch <- prometheus.MustNewConstMetric(c.cpu, prometheus.CounterValue, cpuStat.Iowait, cpuNum, "iowait")
|
|
ch <- prometheus.MustNewConstMetric(c.cpu, prometheus.CounterValue, cpuStat.IRQ, cpuNum, "irq")
|
|
ch <- prometheus.MustNewConstMetric(c.cpu, prometheus.CounterValue, cpuStat.SoftIRQ, cpuNum, "softirq")
|
|
ch <- prometheus.MustNewConstMetric(c.cpu, prometheus.CounterValue, cpuStat.Steal, cpuNum, "steal")
|
|
|
|
if *enableCPUGuest {
|
|
// Guest CPU is also accounted for in cpuStat.User and cpuStat.Nice, expose these as separate metrics.
|
|
ch <- prometheus.MustNewConstMetric(c.cpuGuest, prometheus.CounterValue, cpuStat.Guest, cpuNum, "user")
|
|
ch <- prometheus.MustNewConstMetric(c.cpuGuest, prometheus.CounterValue, cpuStat.GuestNice, cpuNum, "nice")
|
|
}
|
|
}
|
|
|
|
return nil
|
|
}
|
|
|
|
// updateCPUStats updates the internal cache of CPU stats.
|
|
func (c *cpuCollector) updateCPUStats(newStats map[int64]procfs.CPUStat) {
|
|
|
|
// Acquire a lock to update the stats.
|
|
c.cpuStatsMutex.Lock()
|
|
defer c.cpuStatsMutex.Unlock()
|
|
|
|
// Reset the cache if the list of CPUs has changed.
|
|
for i, n := range newStats {
|
|
cpuStats := c.cpuStats[i]
|
|
|
|
// If idle jumps backwards by more than X seconds, assume we had a hotplug event and reset the stats for this CPU.
|
|
if (cpuStats.Idle - n.Idle) >= jumpBackSeconds {
|
|
level.Debug(c.logger).Log("msg", jumpBackDebugMessage, "cpu", i, "old_value", cpuStats.Idle, "new_value", n.Idle)
|
|
cpuStats = procfs.CPUStat{}
|
|
}
|
|
|
|
if n.Idle >= cpuStats.Idle {
|
|
cpuStats.Idle = n.Idle
|
|
} else {
|
|
level.Debug(c.logger).Log("msg", "CPU Idle counter jumped backwards", "cpu", i, "old_value", cpuStats.Idle, "new_value", n.Idle)
|
|
}
|
|
|
|
if n.User >= cpuStats.User {
|
|
cpuStats.User = n.User
|
|
} else {
|
|
level.Debug(c.logger).Log("msg", "CPU User counter jumped backwards", "cpu", i, "old_value", cpuStats.User, "new_value", n.User)
|
|
}
|
|
|
|
if n.Nice >= cpuStats.Nice {
|
|
cpuStats.Nice = n.Nice
|
|
} else {
|
|
level.Debug(c.logger).Log("msg", "CPU Nice counter jumped backwards", "cpu", i, "old_value", cpuStats.Nice, "new_value", n.Nice)
|
|
}
|
|
|
|
if n.System >= cpuStats.System {
|
|
cpuStats.System = n.System
|
|
} else {
|
|
level.Debug(c.logger).Log("msg", "CPU System counter jumped backwards", "cpu", i, "old_value", cpuStats.System, "new_value", n.System)
|
|
}
|
|
|
|
if n.Iowait >= cpuStats.Iowait {
|
|
cpuStats.Iowait = n.Iowait
|
|
} else {
|
|
level.Debug(c.logger).Log("msg", "CPU Iowait counter jumped backwards", "cpu", i, "old_value", cpuStats.Iowait, "new_value", n.Iowait)
|
|
}
|
|
|
|
if n.IRQ >= cpuStats.IRQ {
|
|
cpuStats.IRQ = n.IRQ
|
|
} else {
|
|
level.Debug(c.logger).Log("msg", "CPU IRQ counter jumped backwards", "cpu", i, "old_value", cpuStats.IRQ, "new_value", n.IRQ)
|
|
}
|
|
|
|
if n.SoftIRQ >= cpuStats.SoftIRQ {
|
|
cpuStats.SoftIRQ = n.SoftIRQ
|
|
} else {
|
|
level.Debug(c.logger).Log("msg", "CPU SoftIRQ counter jumped backwards", "cpu", i, "old_value", cpuStats.SoftIRQ, "new_value", n.SoftIRQ)
|
|
}
|
|
|
|
if n.Steal >= cpuStats.Steal {
|
|
cpuStats.Steal = n.Steal
|
|
} else {
|
|
level.Debug(c.logger).Log("msg", "CPU Steal counter jumped backwards", "cpu", i, "old_value", cpuStats.Steal, "new_value", n.Steal)
|
|
}
|
|
|
|
if n.Guest >= cpuStats.Guest {
|
|
cpuStats.Guest = n.Guest
|
|
} else {
|
|
level.Debug(c.logger).Log("msg", "CPU Guest counter jumped backwards", "cpu", i, "old_value", cpuStats.Guest, "new_value", n.Guest)
|
|
}
|
|
|
|
if n.GuestNice >= cpuStats.GuestNice {
|
|
cpuStats.GuestNice = n.GuestNice
|
|
} else {
|
|
level.Debug(c.logger).Log("msg", "CPU GuestNice counter jumped backwards", "cpu", i, "old_value", cpuStats.GuestNice, "new_value", n.GuestNice)
|
|
}
|
|
|
|
c.cpuStats[i] = cpuStats
|
|
}
|
|
|
|
// Remove offline CPUs.
|
|
if len(newStats) != len(c.cpuStats) {
|
|
onlineCPUIds := maps.Keys(newStats)
|
|
maps.DeleteFunc(c.cpuStats, func(key int64, item procfs.CPUStat) bool {
|
|
return !slices.Contains(onlineCPUIds, key)
|
|
})
|
|
}
|
|
}
|