- Improve docs
- Hide `debug relabeling` column when -promscrape.dropOriginalLabels command-line flag is set
- Inline the code from the added template functions, since the code is harder to follow
with the template functions, especially when these functions have misleading names.
Also, these functions are used only in one place, e.g. they do not reduce the amounts of code.
- Hide `click to show original labels` title at `labels` column when original labels aren't available.
- Show the reason on whey original labels aren't available at /service-discovery page.
Updates https://github.com/VictoriaMetrics/VictoriaMetrics/issues/4597
- Parse protobuf if Content-Type isn't set to `application/json` - this behavior is documented at https://grafana.com/docs/loki/latest/api/#push-log-entries-to-loki
- Properly handle gzip'ped JSON requests. The `gzip` header must be read from `Content-Encoding` instead of `Content-Type` header
- Properly flush all the parsed logs with the explicit call to vlstorage.MustAddRows() at the end of query handler
- Check JSON field types more strictly.
- Allow parsing Loki timestamp as floating-point number. Such a timestamp can be generated by some clients,
which store timestamps in float64 instead of int64.
- Optimize parsing of Loki labels in Prometheus text exposition format.
- Simplify tests.
- Remove lib/slicesutil, since there are no more users for it.
- Update docs with missing info and fix various typos. For example, it should be enough to have `instance` and `job` labels
as stream fields in most Loki setups.
- Allow empty of missing timestamps in the ingested logs.
The current timestamp at VictoriaLogs side is then used for the ingested logs.
This simplifies debugging and testing of the provided HTTP-based data ingestion APIs.
The remaining MAJOR issue, which needs to be addressed: victoria-logs binary size increased from 13MB to 22MB
after adding support for Loki data ingestion protocol at https://github.com/VictoriaMetrics/VictoriaMetrics/pull/4482 .
This is because of shitty protobuf dependencies. They must be replaced with another protobuf implementation
similar to the one used at lib/prompb or lib/prompbmarshal .
Loki uses default labels format without "or" operator. This format can't create a list of LabelFilters, so only first set of LabelFilters should be used.
Signed-off-by: Zakhar Bessarab <z.bessarab@victoriametrics.com>
* app/vmagent: fix creating target id if `--promscrape.dropOriginalLabels` flag was used
* app/vmagent: hide links if OriginalLabels was dropped
* app/vmagent: update CHANGELOG.md and added information to the docs
* app/vmagent: fix comments
* app/vlinsert: add support of loki push protocol
- implemented loki push protocol for both Protobuf and JSON formats
- added examples in documentation
- added example docker-compose
Signed-off-by: Zakhar Bessarab <z.bessarab@victoriametrics.com>
* app/vlinsert: move protobuf metric into its own file
Signed-off-by: Zakhar Bessarab <z.bessarab@victoriametrics.com>
* deployment/docker/victorialogs/promtail: update reference to docker image
Signed-off-by: Zakhar Bessarab <z.bessarab@victoriametrics.com>
* deployment/docker/victorialogs/promtail: make volume name unique
Signed-off-by: Zakhar Bessarab <z.bessarab@victoriametrics.com>
* app/vlinsert/loki: add license reference
Signed-off-by: Zakhar Bessarab <z.bessarab@victoriametrics.com>
* deployment/docker/victorialogs/promtail: fix volume name
Signed-off-by: Zakhar Bessarab <z.bessarab@victoriametrics.com>
* docs/VictoriaLogs/data-ingestion: add stream fields for loki JSON ingestion example
Signed-off-by: Zakhar Bessarab <z.bessarab@victoriametrics.com>
* app/vlinsert/loki: move entities to places where those are used
Signed-off-by: Zakhar Bessarab <z.bessarab@victoriametrics.com>
* app/vlinsert/loki: refactor to use common components
- use CommonParameters from insertutils
- stop ingestion after first error similar to elasticsearch and jsonline
Signed-off-by: Zakhar Bessarab <z.bessarab@victoriametrics.com>
* app/vlinsert/loki: address review feedback
- add missing logstorage.PutLogRows calls
- refactor tenant ID parsing to use common function
- reduce number of allocations for parsing by reusing logfields slices
- add tests and benchmarks for requests processing funcs
Signed-off-by: Zakhar Bessarab <z.bessarab@victoriametrics.com>
---------
Signed-off-by: Zakhar Bessarab <z.bessarab@victoriametrics.com>
This eliminates the need in .(*T) casting for results obtained from Load()
Leave atomic.Value for map, since atomic.Pointer[map[...]...] makes double pointer to map,
because map is already a pointer type.
- Add `Active queries` chapter to VMUI docs
- Set `Content-Type: json` header inside promql.WriteActiveQueries() handler,
in order to be consistent with other request handlers called at app/vmselect/main.go
- Pass the request to promql.WriteActiveQueries() handler, so it can change its output
depending on the provided request params. This also improves consistency of
promql.WriteActiveQueries() args with other request hanlers at app/vmselect/main.go
Updates https://github.com/VictoriaMetrics/VictoriaMetrics/pull/4653
* feat: add page to display a list of active queries (#4598)
* app/vmagent: code formatting
* fix: remove console
---------
Co-authored-by: dmitryk-dk <kozlovdmitriyy@gmail.com>
The `a op b keep_metric_names` is ambigouos to `a op (b keep_metric_names)` when `b` is a transform or rollup function.
For example, `a + rate(b) keep_metric_names`. So it is better to use more clear syntax: `(a op b) keep_metric_names`
Updates https://github.com/VictoriaMetrics/VictoriaMetrics/issues/3710
* metricsql: add support of using keep_metric_names for binary operations
This should help to avoid confusion with queries like one in the issue #3710.
Signed-off-by: Zakhar Bessarab <z.bessarab@victoriametrics.com>
* wip
---------
Signed-off-by: Zakhar Bessarab <z.bessarab@victoriametrics.com>
Co-authored-by: Aliaksandr Valialkin <valyala@victoriametrics.com>
Previously all the newly ingested time series were registered in global `MetricName -> TSID` index.
This index was used during data ingestion for locating the TSID (internal series id)
for the given canonical metric name (the canonical metric name consists of metric name plus all its labels sorted by label names).
The `MetricName -> TSID` index is stored on disk in order to make sure that the data
isn't lost on VictoriaMetrics restart or unclean shutdown.
The lookup in this index is relatively slow, since VictoriaMetrics needs to read the corresponding
data block from disk, unpack it, put the unpacked block into `indexdb/dataBlocks` cache,
and then search for the given `MetricName -> TSID` entry there. So VictoriaMetrics
uses in-memory cache for speeding up the lookup for active time series.
This cache is named `storage/tsid`. If this cache capacity is enough for all the currently ingested
active time series, then VictoriaMetrics works fast, since it doesn't need to read the data from disk.
VictoriaMetrics starts reading data from `MetricName -> TSID` on-disk index in the following cases:
- If `storage/tsid` cache capacity isn't enough for active time series.
Then just increase available memory for VictoriaMetrics or reduce the number of active time series
ingested into VictoriaMetrics.
- If new time series is ingested into VictoriaMetrics. In this case it cannot find
the needed entry in the `storage/tsid` cache, so it needs to consult on-disk `MetricName -> TSID` index,
since it doesn't know that the index has no the corresponding entry too.
This is a typical event under high churn rate, when old time series are constantly substituted
with new time series.
Reading the data from `MetricName -> TSID` index is slow, so inserts, which lead to reading this index,
are counted as slow inserts, and they can be monitored via `vm_slow_row_inserts_total` metric exposed by VictoriaMetrics.
Prior to this commit the `MetricName -> TSID` index was global, e.g. it contained entries sorted by `MetricName`
for all the time series ever ingested into VictoriaMetrics during the configured -retentionPeriod.
This index can become very large under high churn rate and long retention. VictoriaMetrics
caches data from this index in `indexdb/dataBlocks` in-memory cache for speeding up index lookups.
The `indexdb/dataBlocks` cache may occupy significant share of available memory for storing
recently accessed blocks at `MetricName -> TSID` index when searching for newly ingested time series.
This commit switches from global `MetricName -> TSID` index to per-day index. This allows significantly
reducing the amounts of data, which needs to be cached in `indexdb/dataBlocks`, since now VictoriaMetrics
consults only the index for the current day when new time series is ingested into it.
The downside of this change is increased indexdb size on disk for workloads without high churn rate,
e.g. with static time series, which do no change over time, since now VictoriaMetrics needs to store
identical `MetricName -> TSID` entries for static time series for every day.
This change removes an optimization for reducing CPU and disk IO spikes at indexdb rotation,
since it didn't work correctly - see https://github.com/VictoriaMetrics/VictoriaMetrics/issues/1401 .
At the same time the change fixes the issue, which could result in lost access to time series,
which stop receving new samples during the first hour after indexdb rotation - see https://github.com/VictoriaMetrics/VictoriaMetrics/issues/2698
The issue with the increased CPU and disk IO usage during indexdb rotation will be addressed
in a separate commit according to https://github.com/VictoriaMetrics/VictoriaMetrics/issues/1401#issuecomment-1553488685
This is a follow-up for 1f28b46ae9
Add a break if gotAlert is nil
This removes the following golangci-lint warning:
app/vmalert/alerting_test.go:868:8: SA5011(related information): this check suggests that the pointer can be nil (staticcheck)
if gotAlert == nil {
^
* app/vmctl: fix panic `--remote-read-filter-time-start` flag not defined
* app/vmctl: update CHANGELOG.md
---------
Co-authored-by: Nikolay <nik@victoriametrics.com>
It could happen for low evaluation intervals and irregular
delays during execution that evaluation time would get
a negative offset. This could result into cumulative
discrepancy between the actual time and evaluation time for rules.
Signed-off-by: hagen1778 <roman@victoriametrics.com>
* docs: make `httpAuth.*` flags description less ambiguous
Currently, it may confuse users whether `httpAuth.*` flags are used by HTTP client or server configuration(see https://github.com/VictoriaMetrics/VictoriaMetrics/issues/4586 for example).
Signed-off-by: Zakhar Bessarab <z.bessarab@victoriametrics.com>
* docs: fix a typo
Signed-off-by: Zakhar Bessarab <z.bessarab@victoriametrics.com>
---------
Signed-off-by: Zakhar Bessarab <z.bessarab@victoriametrics.com>
vmalert: allow disabling of `step` param attached to instant queries
This might be useful for using vmalert with datasources that to not support this param,
unlike VictoriaMetrics.
See https://github.com/VictoriaMetrics/VictoriaMetrics/issues/4573
Signed-off-by: hagen1778 <roman@victoriametrics.com>
libcrypto3 and libssl3 in Alpine 3.18.0 have versions `3.1.0-r4`
which contains CVE-2023-2650:
https://cve.mitre.org/cgi-bin/cvename.cgi?name=CVE-2023-2650
Use ALpine image 3.18.2 which contains fixed versions of libssl3
and libcrypto3: 3.1.1-r0
NB: In Openshift these containers are marked as vulnerabilities
because of these CVEs.
Error message will be present for any auth error, but message claims an error is about OAuth2 configuration which is confusing.
Signed-off-by: Zakhar Bessarab <z.bessarab@victoriametrics.com>
The change focuses on rectifying inconsistencies in the navigation behavior of the application
and eliminating issues encountered when manually altering the URL.
The key updates include:
- Refactoring of the routing mechanism to handle all possible routes and their states.
- Enhancement of the React Router usage to ensure a smoother navigation experience.
- Handling application state when the URL is manually changed.
expose `vmauth_user_request_duration_seconds`
and `vmauth_unauthorized_user_request_duration_seconds` summary metrics
for measuring requests latency per user.
Signed-off-by: hagen1778 <roman@victoriametrics.com>
It is impossible to run OS vmauth with the provided config.
The example of using ip filters should be only a part of docs.
All other examples should work seamlessly with OS version.
Signed-off-by: hagen1778 <roman@victoriametrics.com>
By default, vmalert will make multiple retry attempts with exponential delay.
The total time spent during retry attempts shouldn't exceed `-remoteWrite.retryMaxTime` (default is 30s).
When retry time is exceeded vmalert drops the data dedicated for `-remoteWrite.url`.
Before, vmalert dropped data after 5 retry attempts with 1s delay between attempts (not configurable).
See `-remoteWrite.retryMinInterval` and `-remoteWrite.retryMaxTime` cmd-line flags.
Signed-off-by: hagen1778 <roman@victoriametrics.com>
Co-authored-by: Nikolay <nik@victoriametrics.com>
This reverts commit c19048dc13.
Reason for revert: it has been appeared that the net/http.ResponseWriter is already buffered,
so there in no need in double bufferring
This simplifies routing at auth proxies such as vmauth to vlselect component,
which serves VMUI - just route all the requests, which start with /select/, to vlselect.
vmalert: retry all errors except 4XX status codes
Retry all errors except 4XX status codes while pushing via remote-write
to the remote storage. Previously, errors like broken connection could
prevent vmalert from retrying the request.
Signed-off-by: hagen1778 <roman@victoriametrics.com>
* fix: optimize the preparation of data for the graph
* fix: optimize tooltip rendering
* fix: optimize re-rendering of the chart
* vmui: memory leak fix
app/vmagent/remotewrite: fix vmagent panic on shutdown
Currently, when vmagent is stopping it first flushes pending series in remote write context and proceeds to stop streaming aggregation. This leads to streaming aggregation being unable to write results into pending timeseries (since it is already nil) and panic.
This can lead to losing some aggregation results being lost almost silently.
The fix is reordering flow to first stop streaming aggregation and flush all pending time series after that.
Signed-off-by: Zakhar Bessarab <z.bessarab@victoriametrics.com>
* app/vmctl: add verbose output for docker installations or when TTY isn't available
* app/vmctl: fix tests
* app/vmctl: make vmctl interactive if no tty
* app/vmctl: cleanup
* app/vmctl: add comment
---------
Co-authored-by: Nikolay <nik@victoriametrics.com>
* vmalert: fix nil map assignment
The storage instance with nil map params was created for remote-read purposes.
And before change 7a9ae9de0d this map was ignored in ApplyParams.
Now, it started to be used and vmalert panics in runtime.
The fix properly inits map for at `NewVMStorage` and verifies it is not nil
on assignment in `ApplyParams`.
Signed-off-by: hagen1778 <roman@victoriametrics.com>
* vmalert: add to changelog
Signed-off-by: hagen1778 <roman@victoriametrics.com>
* vmalert: properly clone Storage params
Signed-off-by: hagen1778 <roman@victoriametrics.com>
* vmalert: properly clone Storage params
Signed-off-by: hagen1778 <roman@victoriametrics.com>
* vmalert: properly clone Storage params
Signed-off-by: hagen1778 <roman@victoriametrics.com>
---------
Signed-off-by: hagen1778 <roman@victoriametrics.com>
The purpose of the change is too highlight what HA pair is
and how deduplication needs identical labels to be present
in raw samples.
See https://github.com/VictoriaMetrics/VictoriaMetrics/issues/4367
Signed-off-by: hagen1778 <roman@victoriametrics.com>
at arm based CPUs only 9 digits after comma matches for tests.
Especially at holtWinters functions. Since it only takes effect at tests
it makes no sense for changing float prescision at actual functions
The fix addresses a case when vmalert is configured with a group
which has `name`, but doesn't have `rules` configured. In this
case it still returns a `nil` instead of `[]` slice.
Fixing this via current commit.
See https://github.com/VictoriaMetrics/VictoriaMetrics/issues/4221
Signed-off-by: hagen1778 <roman@victoriametrics.com>
Previously the location inside the sendPrometheusError() was logged.
This could make hard investigating error locations via `vm_log_messages_total` metric.
* added backup locking/unlocking against retention policy to vmbackupmanager
Signed-off-by: Alexander Marshalov <_@marshalov.org>
* added docs for new commands
Signed-off-by: Alexander Marshalov <_@marshalov.org>
* fix review comments
Signed-off-by: Alexander Marshalov <_@marshalov.org>
---------
Signed-off-by: Alexander Marshalov <_@marshalov.org>
* feat: improvement of the top queries page
* vmui/docs: enhancements to top queries page
* Apply suggestions from code review
---------
Co-authored-by: Aliaksandr Valialkin <valyala@victoriametrics.com>
vmui: change default font size to 14px for better readability
vmui: fix bug with missing text on buttons in safari
---------
Co-authored-by: Roman Khavronenko <roman@victoriametrics.com>
* app/vmui: added Labels with the highest number of unique values
* app/vmui: cleanup
* app/vmui: cleanup
* app/vmui: add table description
* app/vmui: fix comment, updated CHANGELOG.md
* app/vmui: disable links
* app/vmui: added actions to the table, it will show values for selected label with the highest number of series
* app/vmui: fix comment
Previously, metric `vmalert_alerting_rules_last_evaluation_series_fetched`
would be set to 0 for const expressions, because const expression do not match
any series. This may result into a confusion: no series were matched but response isn't empty.
The change updates the logic behind metric: if no series were matched but there are samples
in response - use amount of samples as number of series.
Signed-off-by: hagen1778 <roman@victoriametrics.com>
* vmalert: expand rule groups on anchor click
before, anchor click was only updating the URL.
To expand the group, user had to click on rule's block.
Now, group will toggle automatically.
* vmalert: allow filtering group in web UI
The new filter allows to filter groups and rules within
groups by: errors only or noMatch only.
The filtering supposed to help navigating big numbers of groups/rules.
Filtering is reflected in URL, so can be shared as a link.
Signed-off-by: hagen1778 <roman@victoriametrics.com>
Without reset, labels duplicates could have been added during stream aggregation.
Since `ctx.Labels` is reused during processing of many series, each series will
add its labels to the context. Even if the same labels were already addeded on prev
iteration. Now, we reset `ctx.Labels` on each iteration to contain so labels from
different series didn't interfere.
This could have cause exceeding of the limit on number of labels per pushed time series.
https://github.com/VictoriaMetrics/VictoriaMetrics/issues/4277
Signed-off-by: hagen1778 <roman@victoriametrics.com>
app/vmalert: detect alerting rules which don't match any series at all
vmalert starts to understand /query responses which contain object:
```
"stats":{"seriesFetched": "42"}
```
If object is present, vmalert parses it and populates a new field
`SeriesFetched`. This field is then used to populate the new metric
`vmalert_alerting_rules_last_evaluation_series_fetched` and to
display warnings in the vmalert's UI.
If response doesn't contain the new object (Prometheus or
VictoriaMetrics earlier than v1.90), then `SeriesFetched=nil`.
In this case, UI will contain no additional warnings.
And `vmalert_alerting_rules_last_evaluation_series_fetched` will
be set to `-1`. Negative value of the metric will help to compile
correct alerting rule in follow-up.
Thanks for the initial implementation to @Haleygo
See https://github.com/VictoriaMetrics/VictoriaMetrics/pull/4056
See https://github.com/VictoriaMetrics/VictoriaMetrics/issues/4039
Signed-off-by: hagen1778 <roman@victoriametrics.com>