Opentelemetry format allows histograms with non-counter buckets. In this case it makes no sense to add buckets into database
and save only counter with _count suffix.
It could be used as gauge.
https://github.com/VictoriaMetrics/VictoriaMetrics/issues/4814
Co-authored-by: Aliaksandr Valialkin <valyala@victoriametrics.com>
* lib/promrelabel: fix relabeling if clause being applied to labels outside of current context
Relabeling is applied to each metric row separately, but in order to lower amount of memory allocations it is reusing labels.
Functions which are working on current metric row labels are supposed to use only current metric labels by using provided offset, but if clause matcher was using the whole labels set instead of local metrics.
This leaded to invalid relabeling results such as one described here: https://github.com/VictoriaMetrics/VictoriaMetrics/issues/4806
Signed-off-by: Zakhar Bessarab <z.bessarab@victoriametrics.com>
* docs/CHANGELOG.md: document the bugfix
Updates https://github.com/VictoriaMetrics/VictoriaMetrics/issues/1998
Updates https://github.com/VictoriaMetrics/VictoriaMetrics/issues/4806
---------
Signed-off-by: Zakhar Bessarab <z.bessarab@victoriametrics.com>
Co-authored-by: Aliaksandr Valialkin <valyala@victoriametrics.com>
This reverts commit 252643d100.
Reason for revert: the commit incorrectly fixes the the issue.
The `remoteAddr` must be properly quoted inside lib/httpserver.GetQuotedRemoteAddr().
It isn't quoted properly if the request contains X-Forwarded-For header.
The proper fix will be included in the follow-up commit.
Updates https://github.com/VictoriaMetrics/VictoriaMetrics/pull/4676
{vmagent/remotewrite,vminsert/common}: fix dropInput and keepInput flags inconsistency
Sync behavior for dropInput and keepInput flags between single-node and vmagent.
Fix vmagent not respecting dropInput flag and reverse logic for keepInput.
* rename `configErr` to `lastConfigErr` to reduce confusion
* add tests to verify metrics and msg are set properly
* fix mistake when config success metric wasn't restored after an error
Signed-off-by: hagen1778 <roman@victoriametrics.com>
Correctly calculate `Bytes per point` value for single-server and cluster VM dashboards.
Before, the calculation mistakenly accounted for the number of entries in indexdb in
denominator, which could have shown lower values than expected.
Signed-off-by: hagen1778 <roman@victoriametrics.com>
The `ConcurrentFlushesHitTheLimit` could be related to components like
vminsert, vmstorage, vm-single-node and vmagent. Moving this alert
to the `health` section of alerts will be benefitial for all components
and will remove the duplicates from single/cluster alerts.
Signed-off-by: hagen1778 <roman@victoriametrics.com>
The new panel supposed to show whether the number of concurrent
inserts processed by vmagent isn't reaching the limit.
The panel contains recommendation what to do if limit is reached.
Signed-off-by: hagen1778 <roman@victoriametrics.com>
Binary export API protocol can be disabled via `-vm-native-disable-binary-protocol` cmd-line flag when migrating data from VictoriaMetrics. Disabling binary protocol
can be useful for deduplication of the exported data before ingestion.
For this, deduplication need to be configured at `-vm-native-src-addr` side
and `-vm-native-disable-binary-protocol` should be set on vmctl side.
Signed-off-by: hagen1778 <roman@victoriametrics.com>
Links of form `/api/v1/<groupID>/<alertID>/status` were deprecated
in favour of `/api/v1/alerts?group_id=<>&alert_id=<>` links in
v1.79.0. See more details here https://github.com/VictoriaMetrics/VictoriaMetrics/issues/2825
This change removes code responsible for deprecated functionality.
Signed-off-by: hagen1778 <roman@victoriametrics.com>
Adding anchors to the 1.92 changelog breaks consistency
of navigation section at https://docs.victoriametrics.com/CHANGELOG.html
All other releases do not have subsections, so should 1.92.
Signed-off-by: hagen1778 <roman@victoriametrics.com>
* Revert "vmalert: unittest support stale datapoint (#4696)"
This reverts commit 0b44df7ec8.
* Revert "docs: specify min version and limitations for vmalert's unit tests"
This reverts commit a24541bd
Signed-off-by: hagen1778 <roman@victoriametrics.com>
* Revert "vmalert: init unit test (#4596)"
This reverts commit da60a68d
Signed-off-by: hagen1778 <roman@victoriametrics.com>
* docs: mention unittest revert in changelog
Signed-off-by: hagen1778 <roman@victoriametrics.com>
---------
Signed-off-by: hagen1778 <roman@victoriametrics.com>
* lib/protoparser: adds opentelemetry parser
app/{vmagent,vminsert}: adds opentelemetry ingestion path
Adds ability to ingest data with opentelemetry protocol
protobuf and json encoding is supported
data converted into prometheus protobuf timeseries
each data type has own converter and it may produce multiple timeseries
from single datapoint (for summary and histogram).
only cumulative aggregationFamily is supported for sum(prometheus
counter) and histogram.
Apply suggestions from code review
Co-authored-by: Roman Khavronenko <roman@victoriametrics.com>
updates deps
fixes tests
wip
wip
wip
wip
lib/protoparser/opentelemetry: moves to vtprotobuf generator
go mod vendor
lib/protoparse/opentelemetry: reduce memory allocations
* wip
- Remove support for JSON parsing, since it is too fragile and is rarely used in practice.
The most clients send OpenTelemetry metrics in protobuf.
The JSON parser can be added in the future if needed.
- Remove unused code from lib/protoparser/opentelemetry/pb and lib/protoparser/opentelemetry/proto
- Do not re-use protobuf message between ParseStream() calls, since there is high chance
of high fragmentation of the re-used message because of too complex nested structure of the message.
* wip
* wip
* wip
---------
Co-authored-by: Aliaksandr Valialkin <valyala@victoriametrics.com>
Add -remoteWrite.shardByURL command-line flag, which instructs vmagent to spread evenly
outgoing time series data among the configured remote storage systems specified via -remoteWrite.url .
Samples for the same time series go to the same -remoteWrite.url . This allows building horizontally
scalable stream aggregation when samples for counter and histogram series must be aggregated
by the same second-level vmagent instance.
Updates https://github.com/VictoriaMetrics/VictoriaMetrics/issues/4637
- Use a byte slice instead of a map for tracking indexes for matching series.
This improves performance, since access by slice index is faster than access by map key.
- Re-use the byte slice for tracking indexes for matching series.
This removes unnecessary memory allocations and improves stream aggregation performance a bit.
- Add an ability to return to the previous behvaiour by specifying -remoteWrite.streamAggr.dropInput command-line flag.
In this case all the input samples are dropped when stream aggregation is enabled.
- Backport the new stream aggregation behaviour from vmagent to single-node VictoriaMetrics when -streamAggr.config
option is set.
- Improve docs regarding this change at docs/CHANGELOG.md
- Document the new behavior at docs/stream-aggregation.md
Updates https://github.com/VictoriaMetrics/VictoriaMetrics/issues/4243
Updates https://github.com/VictoriaMetrics/VictoriaMetrics/pull/4575
* {lib/streamaggr,vmagent/remotewrite}: breaking change for keepInput flag
Changes default behaviour of keepInput flag to write series which did not match any aggregators to the remote write.
See: https://github.com/VictoriaMetrics/VictoriaMetrics/issues/4243
Signed-off-by: Zakhar Bessarab <z.bessarab@victoriametrics.com>
* Update app/vmagent/remotewrite/remotewrite.go
Co-authored-by: Roman Khavronenko <roman@victoriametrics.com>
---------
Signed-off-by: Zakhar Bessarab <z.bessarab@victoriametrics.com>
Co-authored-by: Roman Khavronenko <roman@victoriametrics.com>
Co-authored-by: Aliaksandr Valialkin <valyala@victoriametrics.com>
* lib/storage: pre-create timeseries before indexDB rotation
during an hour before indexDB rotation start creating records at the next indexDB
it must improve performance during switch for the next indexDB and remove ingestion issues.
Since there is no need for creation new index records for timeseries already ingested into current indexDB
https://github.com/VictoriaMetrics/VictoriaMetrics/issues/4563
* lib/storage: further work on indexdb rotation optimization
- Document the change at docs/CHAGNELOG.md
- Move back various caches from indexDB to Storage. This makes the change less intrusive.
The dateMetricIDCache now takes into account indexDB generation, so it stores (date, metricID)
entries for both the current and the next indexDB.
- Consolidate the code responsible for idbNext pre-filling into prefillNextIndexDB() function.
This improves code readability and maintainability a bit.
- Rewrite and simplify the code responsible for calculating the next retention timestamp.
Add various tests for corner cases of this code.
- Remove indexdb pre-filling from RegisterMetricNames() function, since this function is rarely called.
It is OK to add indexdb entries on demand in this function. This simplifies the code.
Updates https://github.com/VictoriaMetrics/VictoriaMetrics/issues/1401
* docs/CHANGELOG.md: refer to https://github.com/VictoriaMetrics/VictoriaMetrics/issues/4563
---------
Co-authored-by: Aliaksandr Valialkin <valyala@victoriametrics.com>
* app/vmalert/datasource/graphite: allow overriding "from" parameter for datasource queries
Fixes construction of URL parameters for graphite render to allow overriding "from" parameter.
See: https://github.com/VictoriaMetrics/VictoriaMetrics/issues/4685
Signed-off-by: Zakhar Bessarab <z.bessarab@victoriametrics.com>
* app/vmalert/datasource/graphite: update flow for building URL parameters
Makes flow of building URL parameters same as Prometheus datasource has:
1) Setting all default values
2) Merging those values with provided `extraParams`
Signed-off-by: Zakhar Bessarab <z.bessarab@victoriametrics.com>
* Update docs/CHANGELOG.md
Co-authored-by: Roman Khavronenko <roman@victoriametrics.com>
---------
Signed-off-by: Zakhar Bessarab <z.bessarab@victoriametrics.com>
Co-authored-by: Roman Khavronenko <roman@victoriametrics.com>
- Improve docs
- Hide `debug relabeling` column when -promscrape.dropOriginalLabels command-line flag is set
- Inline the code from the added template functions, since the code is harder to follow
with the template functions, especially when these functions have misleading names.
Also, these functions are used only in one place, e.g. they do not reduce the amounts of code.
- Hide `click to show original labels` title at `labels` column when original labels aren't available.
- Show the reason on whey original labels aren't available at /service-discovery page.
Updates https://github.com/VictoriaMetrics/VictoriaMetrics/issues/4597
* app/vmagent: fix creating target id if `--promscrape.dropOriginalLabels` flag was used
* app/vmagent: hide links if OriginalLabels was dropped
* app/vmagent: update CHANGELOG.md and added information to the docs
* app/vmagent: fix comments
* feat: add page to display a list of active queries (#4598)
* app/vmagent: code formatting
* fix: remove console
---------
Co-authored-by: dmitryk-dk <kozlovdmitriyy@gmail.com>
The `a op b keep_metric_names` is ambigouos to `a op (b keep_metric_names)` when `b` is a transform or rollup function.
For example, `a + rate(b) keep_metric_names`. So it is better to use more clear syntax: `(a op b) keep_metric_names`
Updates https://github.com/VictoriaMetrics/VictoriaMetrics/issues/3710
* metricsql: add support of using keep_metric_names for binary operations
This should help to avoid confusion with queries like one in the issue #3710.
Signed-off-by: Zakhar Bessarab <z.bessarab@victoriametrics.com>
* wip
---------
Signed-off-by: Zakhar Bessarab <z.bessarab@victoriametrics.com>
Co-authored-by: Aliaksandr Valialkin <valyala@victoriametrics.com>
Previously all the newly ingested time series were registered in global `MetricName -> TSID` index.
This index was used during data ingestion for locating the TSID (internal series id)
for the given canonical metric name (the canonical metric name consists of metric name plus all its labels sorted by label names).
The `MetricName -> TSID` index is stored on disk in order to make sure that the data
isn't lost on VictoriaMetrics restart or unclean shutdown.
The lookup in this index is relatively slow, since VictoriaMetrics needs to read the corresponding
data block from disk, unpack it, put the unpacked block into `indexdb/dataBlocks` cache,
and then search for the given `MetricName -> TSID` entry there. So VictoriaMetrics
uses in-memory cache for speeding up the lookup for active time series.
This cache is named `storage/tsid`. If this cache capacity is enough for all the currently ingested
active time series, then VictoriaMetrics works fast, since it doesn't need to read the data from disk.
VictoriaMetrics starts reading data from `MetricName -> TSID` on-disk index in the following cases:
- If `storage/tsid` cache capacity isn't enough for active time series.
Then just increase available memory for VictoriaMetrics or reduce the number of active time series
ingested into VictoriaMetrics.
- If new time series is ingested into VictoriaMetrics. In this case it cannot find
the needed entry in the `storage/tsid` cache, so it needs to consult on-disk `MetricName -> TSID` index,
since it doesn't know that the index has no the corresponding entry too.
This is a typical event under high churn rate, when old time series are constantly substituted
with new time series.
Reading the data from `MetricName -> TSID` index is slow, so inserts, which lead to reading this index,
are counted as slow inserts, and they can be monitored via `vm_slow_row_inserts_total` metric exposed by VictoriaMetrics.
Prior to this commit the `MetricName -> TSID` index was global, e.g. it contained entries sorted by `MetricName`
for all the time series ever ingested into VictoriaMetrics during the configured -retentionPeriod.
This index can become very large under high churn rate and long retention. VictoriaMetrics
caches data from this index in `indexdb/dataBlocks` in-memory cache for speeding up index lookups.
The `indexdb/dataBlocks` cache may occupy significant share of available memory for storing
recently accessed blocks at `MetricName -> TSID` index when searching for newly ingested time series.
This commit switches from global `MetricName -> TSID` index to per-day index. This allows significantly
reducing the amounts of data, which needs to be cached in `indexdb/dataBlocks`, since now VictoriaMetrics
consults only the index for the current day when new time series is ingested into it.
The downside of this change is increased indexdb size on disk for workloads without high churn rate,
e.g. with static time series, which do no change over time, since now VictoriaMetrics needs to store
identical `MetricName -> TSID` entries for static time series for every day.
This change removes an optimization for reducing CPU and disk IO spikes at indexdb rotation,
since it didn't work correctly - see https://github.com/VictoriaMetrics/VictoriaMetrics/issues/1401 .
At the same time the change fixes the issue, which could result in lost access to time series,
which stop receving new samples during the first hour after indexdb rotation - see https://github.com/VictoriaMetrics/VictoriaMetrics/issues/2698
The issue with the increased CPU and disk IO usage during indexdb rotation will be addressed
in a separate commit according to https://github.com/VictoriaMetrics/VictoriaMetrics/issues/1401#issuecomment-1553488685
This is a follow-up for 1f28b46ae9
* app/vmctl: fix panic `--remote-read-filter-time-start` flag not defined
* app/vmctl: update CHANGELOG.md
---------
Co-authored-by: Nikolay <nik@victoriametrics.com>
It could happen for low evaluation intervals and irregular
delays during execution that evaluation time would get
a negative offset. This could result into cumulative
discrepancy between the actual time and evaluation time for rules.
Signed-off-by: hagen1778 <roman@victoriametrics.com>
* vmselect: introduce `search.skipSlowReplicas` cmd-line flag
vmselect has two logical conditions during request processing when
`-replicationFactor` cmd-line flag is set:
1. If at least `len(storageNodes) - replicationFactor` responded, it could skip
waiting for the rest of nodes to respond. This could lead to problems described
here https://github.com/VictoriaMetrics/VictoriaMetrics/issues/1207.
2. Mark response as partial if less than `len(storageNodes) - replicationFactor` responded
without an error.
The P1 showed itself error-prone and became the main reason why
`-replicationFactor` wasn't recommended to use at vmselect level.
However, this optimization could be still very useful in situations
when there are slow and fast replicas in cluster.
But P2 remains viable and important conditionless.
Hiding P1 behind the feature-flag `search.skipSlowReplicas`
should make `-replicationFactor` flag usable again. And let users
choose whether they want P1 to be respected.
Related issues
https://github.com/VictoriaMetrics/VictoriaMetrics/issues/1207https://github.com/VictoriaMetrics/VictoriaMetrics/issues/711
Signed-off-by: hagen1778 <roman@victoriametrics.com>
* docs: update changelog
Signed-off-by: hagen1778 <roman@victoriametrics.com>
---------
Signed-off-by: hagen1778 <roman@victoriametrics.com>
vmalert: allow disabling of `step` param attached to instant queries
This might be useful for using vmalert with datasources that to not support this param,
unlike VictoriaMetrics.
See https://github.com/VictoriaMetrics/VictoriaMetrics/issues/4573
Signed-off-by: hagen1778 <roman@victoriametrics.com>
* fix removing storage data dir before restoring from backup
Signed-off-by: Alexander Marshalov <_@marshalov.org>
* fix review comment
Signed-off-by: Alexander Marshalov <_@marshalov.org>
* fix review comment
Signed-off-by: Alexander Marshalov <_@marshalov.org>
* fixes after merge with `enterprise-single-node` branch
Signed-off-by: Alexander Marshalov <_@marshalov.org>
---------
Signed-off-by: Alexander Marshalov <_@marshalov.org>
- Clarify the scope of the fix at docs/CHANGELOG.md
- Handle the case when -search.maxSamplesPerSeries limit is exceeded
in the same way as the -search.maxSamplesPerQuery limit.
Updates https://github.com/VictoriaMetrics/VictoriaMetrics/pull/4472
The validation was needed for covering corner cases when storage is tested with data from 1970.
This resulted into unexpected search results, as year was parsed incorrectly from the given timestamp.
Co-authored-by: hagen1778 <roman@victoriametrics.com>
The change focuses on rectifying inconsistencies in the navigation behavior of the application
and eliminating issues encountered when manually altering the URL.
The key updates include:
- Refactoring of the routing mechanism to handle all possible routes and their states.
- Enhancement of the React Router usage to ensure a smoother navigation experience.
- Handling application state when the URL is manually changed.