`median_over_time` is handled by predefined WITH template in MetricsQL library which translates it to `quantile_over_time(0.5)`
This makes it impossble to use `median_over_time` as a usual rollup function for `aggr_over_time`.
See: https://github.com/VictoriaMetrics/VictoriaMetrics/issues/5034
Signed-off-by: Zakhar Bessarab <z.bessarab@victoriametrics.com>
lib/promscrape/discovery/kubernetes: supress context.Cancelled error in logs
It is possible that context.Cancelled will appear after k8s watcher was closed due to reload(see https://github.com/VictoriaMetrics/VictoriaMetrics/issues/4850).
Logging an error misinforms user and looks like vmagent discovery will stop working even though this does not affect discovery.
Signed-off-by: Zakhar Bessarab <z.bessarab@victoriametrics.com>
(cherry picked from commit 8d99c12a7d)
* lib/backup: fix issue with inconsistent copying of appliedRetention.txt
appliedRetention.txt can be modified in place, so it should be always copied just the same as parts.json
Updates: https://github.com/victoriaMetrics/victoriaMetrics/issues/5005
Signed-off-by: Zakhar Bessarab <z.bessarab@victoriametrics.com>
* docs: add changelog entry for appliedRetention.txt copying fix
Signed-off-by: Zakhar Bessarab <z.bessarab@victoriametrics.com>
---------
Signed-off-by: Zakhar Bessarab <z.bessarab@victoriametrics.com>
* expose metrics `vmauth_config_last_reload_*` for tracking the state of config reloads, similarly to vmagent/vmalert components.
* do not print logs like `SIGHUP received...` once per configured `-configCheckInterval` cmd-line flag. This log will be printed only if config reload was invoked manually.
* prevent configuration reloading if there were no changes in config. This improves memory usage when `-configCheckInterval` cmd-line flag is configured and config has extensive list of regexp expressions requiring additional memory on parsing.
Signed-off-by: hagen1778 <roman@victoriametrics.com>
- Switch from summary to histogram for vl_http_request_duration_seconds metric.
This allows calculating request duration quantiles across multiple hosts
via histogram_quantile(0.99, sum(vl_http_request_duration_seconds_bucket) by (vmrange)).
- Take into account only successfully processed data ingestion requests
when updating vl_http_request_duration_seconds histogram.
Failed requests are ignored, since they may significantly skew measurements.
- Clarify the description of the change at docs/VictoriaLogs/CHANGELOG.md.
Updates https://github.com/VictoriaMetrics/VictoriaMetrics/pull/4934
- Move the bugfix description to the correct place in docs/CHANGELOG.md
- Prevent from logging of 'context canceled' errors after the url watcher is stopped,
since these errors are expected and may confuse users.
- Remove unused urlWatcher.refCount field.
- Remove unused urlWatcher.close() method.
Updates https://github.com/VictoriaMetrics/VictoriaMetrics/issues/4850
* lib/promscrape/discovery/kubernetes: fix leaking api watcher
goroutine which was polling k8s API had no execution control. This leaded to leaking goroutines during config reload.
See: https://github.com/VictoriaMetrics/VictoriaMetrics/issues/4850
Signed-off-by: Zakhar Bessarab <z.bessarab@victoriametrics.com>
* lib/promscrape/discovery/kubernetes: use reference counting for urlWatcher cleanup
Signed-off-by: Zakhar Bessarab <z.bessarab@victoriametrics.com>
* lib/promscrape/discovery/kubernetes: remove waitgroup sync for goroutines polling API server
This is unnecessary since context will is cancelled and new requests will not be sent. Also, using waitgroup will increase time required to perform reload which might result in missed scrapes.
Signed-off-by: Zakhar Bessarab <z.bessarab@victoriametrics.com>
* lib/promscrape/discovery/kubernetes: clarify comment
Signed-off-by: Zakhar Bessarab <z.bessarab@victoriametrics.com>
* Apply suggestions from code review
* lib/promscrape/discovery/kubernetes: address review feedback
Signed-off-by: Zakhar Bessarab <z.bessarab@victoriametrics.com>
---------
Signed-off-by: Zakhar Bessarab <z.bessarab@victoriametrics.com>
Co-authored-by: Nikolay <nik@victoriametrics.com>
* lib/backup: force copying of parts.json
Copying of parts.json is required because `part.key()` comparison can create same key value for files with different contents. This will result in inconsistent backup being created or restored.
See: https://github.com/VictoriaMetrics/VictoriaMetrics/issues/5005
Signed-off-by: Zakhar Bessarab <z.bessarab@victoriametrics.com>
* lib/backup: ensure parts.json is only copied once
Signed-off-by: Zakhar Bessarab <z.bessarab@victoriametrics.com>
---------
Signed-off-by: Zakhar Bessarab <z.bessarab@victoriametrics.com>
Co-authored-by: Nikolay <nik@victoriametrics.com>
Adding limit on ingestion allows to avoid issues like this one https://github.com/VictoriaMetrics/VictoriaMetrics/issues/4762
Such issues are often caused by misconfigurtion on log persing/ingestion side and preventing such rows from being ingested allows to avoid performance implications created by storing such log rows.
Signed-off-by: Zakhar Bessarab <z.bessarab@victoriametrics.com>
This should prevent from emitting too long lines when too long args are passed to logger.* functions.
For example, too long MetricsQL queries or too long data samples.