Previously (f1:foo OR f2:bar) was incorrectly returning `foo` token for `f1` and `bar` token for `f2`.
These tokens were used for checking against bloom filter for every data block, so the data block,
which didn't contain simultaneously `foo` token for `f1` field and `bar` token for `f2` field, was skipped.
This was incorrect, since such a block may contain logs matching the original OR filter.
The fix is to return common tokens from `OR`-delimted filters only if these tokens exist at EVERY such filter
for the given field name. If some `OR`-delimited filter misses the given field name, then `OR`-delimited filters
do not contain common tokens, which could be used for checking against bloom filter.
While at it, add more tests covering various edge cases for filters delimited by AND and OR.
Updates https://github.com/VictoriaMetrics/VictoriaMetrics/issues/6554
Updates https://github.com/VictoriaMetrics/VictoriaMetrics/pull/6556
### Describe Your Changes
Upgraded victoriametrics and victorialogs data source versions.
### Checklist
The following checks are **mandatory**:
- [x] My change adheres [VictoriaMetrics contributing
guidelines](https://docs.victoriametrics.com/contributing/).
### Describe Your Changes
Please provide a brief description of the changes you made. Be as
specific as possible to help others understand the purpose and impact of
your modifications.
### Checklist
The following checks are **mandatory**:
- [ ] My change adheres [VictoriaMetrics contributing
guidelines](https://docs.victoriametrics.com/contributing/).
Signed-off-by: hagen1778 <roman@victoriametrics.com>
Commit adds the following changes:
* Adds support of OpenTelemetry logs for Victoria Logs with protobuf encoded messages
* json encoding is not supported for the following reasons:
- It brings a lot of fragile code, which works inefficiently.
- json encoding is impossible to use with language SDK.
* splits metrics and logs structures at lib/protoparser/opentelemetry/pb package.
* adds docs with examples for opentelemetry logs.
---
Related issue: https://github.com/VictoriaMetrics/VictoriaMetrics/issues/4839
Co-authored-by: AndrewChubatiuk <andrew.chubatiuk@gmail.com>
Co-authored-by: f41gh7 <nik@victoriametrics.com>
* updates change log
* adds VL-Debug http header
* updates doc
* extracts only the first value of http headers for VL-Stream-Fields and VL-Ignore-Fields.
It makes behaviour the same as Query string args. And allows to easily configure client applications.
Since most of the client collectors don't support multi value headers.
Signed-off-by: f41gh7 <nik@victoriametrics.com>
* Many collectors don't support forwarding url query params to the remote system. It makes impossible to define stream fields for it. Workaround with proxy between VictoriaLogs and log shipper is too complicated solution.
* This commit adds the following changes:
* Adds fallback to to headers params, if query param is empty for:
_msg_field -> VL-Msg-Field
_stream_fields -> VL-Stream-Fields
_ignore_fields -> VL-Ignore-Fields
_time_field -> VL-Time-Field
* removes deprecations from victorialogs compose files, added more
output format examples for logstash, telegraf, fluent-bit
related issue: https://github.com/VictoriaMetrics/VictoriaMetrics/issues/5310
Recent versions of `docker build` started generating the InvalidDefaultArgInFrom warning if Dockerfile contains
an ARG without default value. While this warning doesn't affect building Docker packages via `make package-*` commands,
it is better suppressing the warning, so it doesn't clutter `make package-*` output with the noise,
which can hide real issues in the future.
…specifying `-streamAggr.dedupInterval` or
`-remoteWrite.streamAggr.dedupInterval` command-line flag
[The
documentation](https://docs.victoriametrics.com/stream-aggregation/)
contains conflicting descriptions regarding deduplication for
non-matched series when `-remoteWrite.streamAggr.config` and / or
`-streamAggr.config` are set:
1. Statement below says **all the received data** is deduplicated:
>[vmagent](https://docs.victoriametrics.com/vmagent/) supports
relabeling, deduplication and stream aggregation for all the received
data, scraped or pushed. Then, the collected data will be forwarded to
specified -remoteWrite.url destinations. The data processing order is
the following:
>1. all the received data is relabeled according to the specified
[-remoteWrite.relabelConfig](https://docs.victoriametrics.com/vmagent/#relabeling)
(if it is set)
>2. all the received data is deduplicated according to specified
[-streamAggr.dedupInterval](https://docs.victoriametrics.com/stream-aggregation/#deduplication)
(if it is set to duration bigger than 0)
2. Another statement says the deduplication is performed individually
for the **matching samples**
>The de-deduplication is performed after applying
[relabeling](https://docs.victoriametrics.com/vmagent/#relabeling) and
before performing the aggregation. If the -remoteWrite.streamAggr.config
and / or -streamAggr.config is set, then the de-duplication is performed
individually per each [stream aggregation
config](https://docs.victoriametrics.com/stream-aggregation/#stream-aggregation-config)
for the matching samples after applying
[input_relabel_configs](https://docs.victoriametrics.com/stream-aggregation/#relabeling).
Considering the following deduplication use cases:
1. To apply deduplication(globally or for specific remoteWrite
destination) for all the received data, scraped or pushed
--- using `-streamAggr.dedupInterval` or
`-remoteWrite.streamAggr.dedupInterval`.
2. To deduplicate and aggregate metrics that match the rule `match`
filters
--- using `-remoteWrite.streamAggr.config` and specifiying
`dedup_interval` option in [stream aggregation
config](https://docs.victoriametrics.com/stream-aggregation/#stream-aggregation-config).
3. To deduplicate all the received data while having `streamAggr.config`
for some metrics
--- no way for a single vmagent now, need to set up two level vmagents
This PR implements case3.
---------
Co-authored-by: Roman Khavronenko <roman@victoriametrics.com>
(cherry picked from commit d523015f27)
### Describe Your Changes
Correct the spelling error of 'vminsert' in the dashboards.
### Checklist
The following checks are **mandatory**:
- [ ] My change adheres [VictoriaMetrics contributing
guidelines](https://docs.victoriametrics.com/contributing/).
(cherry picked from commit 1b1e61030b)
The 3 alerts for VMagent:
- `RejectedRemoteWriteDataBlocksAreDropped`
- `TooManyScrapeErrors`
- `TooManyWriteErrors`
missed the description annotation.
I moved the summary to description and added a generic summary to these
alerts.
### Checklist
The following checks are **mandatory**:
- [x] My change adheres [VictoriaMetrics contributing
guidelines](https://docs.victoriametrics.com/contributing/).
Signed-off-by: Marco Maurer <marco.kilchhofer@gmail.com>
(cherry picked from commit f17fca718d)
fix#6554
andfilter shouldn't return orfilter field which result in bloomfilter
return false.
---------
Co-authored-by: hagen1778 <roman@victoriametrics.com>
(cherry picked from commit 975ed27a76)
The prev links like `/changelog_2021/`
stopped working after 9dc8d1debd
because these files now require specifying the parent `changelog` in the path, like `/changelog/changelog_2021/`.
This fix adds an alias for an old link.
Signed-off-by: hagen1778 <roman@victoriametrics.com>
(cherry picked from commit 9d94573572)
### Describe Your Changes
This is a follow-up PR: Unit tests introduced in #6872 can now use
RowsAddedTotal counter whose scope was fixed in #6841.
### Checklist
The following checks are **mandatory**:
- [x] My change adheres [VictoriaMetrics contributing
guidelines](https://docs.victoriametrics.com/contributing/).
Signed-off-by: Artem Fetishev <wwctrsrx@gmail.com>
Co-authored-by: Nikolay <nik@victoriametrics.com>
(cherry picked from commit 2c856c6951)
### Describe Your Changes
fsync() ensures that the data is written to disk. In production this is
needed for data durability. However, during the development, when the
unit tests are run, this level of durability is not needed. Therefore
fsync() can be disabled which will makes test runs two times faster.
The disabling is done by setting the `DISABLE_FSYNC_FOR_TESTING`
environment variable. The valid values for this variable are the same as
the values of the arg of `go doc strconv.ParseBool`:
```
1, t, T, TRUE, true, True, 0, f, F, FALSE, false, False.
```
Any other value means `false`.
The variable is set for all test build targets. Compare running times:
Build Target | DISABLE_FSYNC_FOR_TESTING=0 | DISABLE_FSYNC_FOR_TESTING=1
----------------- | ------------------------------------------------ |
-------------------------------------------------
make test | 1m5s | 0m22s
make test-race | 3m1s | 1m42s
make test-pure | 1m7s | 0m20s
make test-full | 1m21s | 0m32s
make test-full-386 | 1m42s | 0m36s
When running tests for a given package, fsync can be disabled as
follows:
```shell
DISABLE_FSYNC_FOR_TESTING=1 go test ./lib/storage
```
Disabling fsync() is intended for testing purposes only and the name of
the variables reflects that.
What could also have been done but haven't:
- lib/filestream/filestream.go: `Writer.MustFlush()` also uses f.Sync()
but nothing has been done to it, because the Writer.MustFlush() is not
used anywhere in the VM codebase. A side question: what is the general
policy for the unused code?
- lib/filestream/filestream.go: Writer.Write() calls `adviceDontNeed()`
which calls unix.Fdatasync(). Disabling it could potentially improve
running time, but running tests with this code disabled has shown
otherwise.
### Checklist
The following checks are **mandatory**:
- [ x] My change adheres [VictoriaMetrics contributing
guidelines](https://docs.victoriametrics.com/contributing/).
---------
Signed-off-by: Artem Fetishev <wwctrsrx@gmail.com>
(cherry picked from commit 334cd92a6c)
Signed-off-by: hagen1778 <roman@victoriametrics.com>
### Describe Your Changes
Add mentions of VictoriaMetrics Cloud to the documentation of vmalert
where this info is helpful to a user.
### Checklist
The following checks are **mandatory**:
- [x] My change adheres [VictoriaMetrics contributing
guidelines](https://docs.victoriametrics.com/contributing/).
---------
Co-authored-by: Roman Khavronenko <roman@victoriametrics.com>
(cherry picked from commit 8a8a1d5df2)
### Describe Your Changes
Describe steps to run VictoriaMetrics Single node or Cluster on
VictoriaMetrics Cloud
### Checklist
The following checks are **mandatory**:
- [x] My change adheres [VictoriaMetrics contributing
guidelines](https://docs.victoriametrics.com/contributing/).
---------
Signed-off-by: hagen1778 <roman@victoriametrics.com>
Co-authored-by: hagen1778 <roman@victoriametrics.com>
(cherry picked from commit f6278d99dd)
### Describe Your Changes
This pull request fixes incorrect URLs in two places:
1. In the OTel guide, which has been corrected in
https://github.com/VictoriaMetrics/VictoriaMetrics/pull/6880, but one
incorrect URL is still missing.
2. In the URL example, the cache reset endpoint for vmselect / Cluster
version is `/internal/resetRollupResultCache`, but it is mistakenly
noted as `/select/internal/resetRollupResultCache`, which misguides the
user. (introduced in #4468)
### Checklist
The following checks are **mandatory**:
- [x] My change adheres [VictoriaMetrics contributing
guidelines](https://docs.victoriametrics.com/contributing/).
(cherry picked from commit f572365a93)
* typo fix
* mention version starting from features are available
Signed-off-by: hagen1778 <roman@victoriametrics.com>
(cherry picked from commit e71cfdcfa5)
Previously, some extIndexDB metrics were not registered. It resulted
into missing metrics, if metric value was added to the extIndexDB. It's
a usual case for search requests at both indexes.
Current commit updates all metrics from extIndexDB according to the
current IndexDB. It must fix such cases
Related issue:
https://github.com/VictoriaMetrics/VictoriaMetrics/issues/6868
### Describe Your Changes
Please provide a brief description of the changes you made. Be as
specific as possible to help others understand the purpose and impact of
your modifications.
### Checklist
The following checks are **mandatory**:
- [ ] My change adheres [VictoriaMetrics contributing
guidelines](https://docs.victoriametrics.com/contributing/).
(cherry picked from commit 4ecc370acb)
### Describe Your Changes
The anchor to "Other fields" section should be #other-fields (instead of
#other-field)
### Checklist
The following checks are **mandatory**:
- [x] My change adheres [VictoriaMetrics contributing
guidelines](https://docs.victoriametrics.com/contributing/).
Signed-off-by: Cuong Le <cuongleqq@gmail.com>
(cherry picked from commit 6154bc9466)
`TL;DR` This PR improves the metric IDs search in IndexDB:
- Avoid seaching for metric IDs twice when `maxMetrics` limit is
exceeded
- Use correct error type for indicating that the `maxMetrics` limit is
exceded
- Simplify the logic of deciding between per-day and global index search
A unit test has been added to ensure that this refactoring does not
break anything.
---
Function calls before the fix:
```
idb.searchMetricIDs
|__ is.searchMetricIDs
|__ is.searchMetricIDsInternal
|__ is.updateMetricIDsForTagFilters
|__ is.tryUpdatingMetricIDsForDateRange
| |
|__ is.getMetricIDsForDateAndFilters
```
- `searchMetricIDsInternal` searches metric IDs for each filter set. It
maintains a metric ID set variable which is updated every time the
`updateMetricIDsForTagFilters` function is called. After each successful
call, the function checks the length of the updated metric ID set and if
it is greater than `maxMetrics`, the function returns `too many
timeseries` error.
- `updateMetricIDsForTagFilters` uses either per-day or global index to
search metric IDs for the given filter set. The decision of which index
to use is made is made within the `tryUpdatingMetricIDsForDateRange`
function and if it returns `fallback to global search` error then the
function uses global index by calling `getMetricIDsForDateAndFilters`
with zero date.
- `tryUpdatingMetricIDsForDateRange` first checks if the given time
range is larger than 40 days and if so returns `fallback to global
search` error. Otherwise it proceeds to searching for metric IDs within
that time range by calling `getMetricIDsForDateAndFilters` for each
date.
- `getMetricIDsForDateAndFilters` searches for metric IDs for the given
date and returns `fallback to global search` error if the number of
found metric IDs is greater than `maxMetrics`.
Problems with this solution:
1. The `fallback to global search` error returned by
`getMetricIDsForDateAndFilters` in case when maxMetrics is exceeded is
misleading.
2. If `tryUpdatingMetricIDsForDateRange` proceeds to date range search
and returns `fallback to global search` error (because
`getMetricIDsForDateAndFilters` returns it) then this will trigger
global search in `updateMetricIDsForTagFilters`. However the global
search uses the same maxMetrics value which means this search is
destined to fail too. I.e. the same search is performed twice and fails
twice.
3. `too many timeseries` error is already handled in
`searchMetricIDsInternal` and therefore handing this error in
`updateMetricIDsForTagFilters` is redundant
4. updateMetricIDsForTagFilters is a better place to make a decision on
whether to use per-day or global index.
Solution:
1. Use a dedicated error for `too many timeseries` case
2. Handle `too many timeseries` error in `searchMetricIDsInternal` only
3. Move the per-day or global search decision from
`tryUpdatingMetricIDsForDateRange` to `updateMetricIDsForTagFilters` and
remove `fallback to global search` error.
---------
Signed-off-by: Artem Fetishev <wwctrsrx@gmail.com>
Co-authored-by: Nikolay <nik@victoriametrics.com>