VictoriaMetrics/lib/netutil/conn.go
Aliaksandr Valialkin 3052b479b7 lib/httpserver: reduce typical duration for http server graceful shutdown
Previously the duration for graceful shutdown for http server could take more than a minute
because of imporperly set timeouts in setNetworkTimeout.
Now typical duration for graceful shutdown should be reduced to less than 5 seconds.
2020-05-07 14:16:38 +03:00

96 lines
2.6 KiB
Go

package netutil
import (
"fmt"
"io"
"net"
"sync/atomic"
"github.com/VictoriaMetrics/metrics"
)
type connMetrics struct {
readCalls *metrics.Counter
readBytes *metrics.Counter
readErrors *metrics.Counter
readTimeouts *metrics.Counter
writeCalls *metrics.Counter
writtenBytes *metrics.Counter
writeErrors *metrics.Counter
writeTimeouts *metrics.Counter
closeErrors *metrics.Counter
conns *metrics.Counter
}
func (cm *connMetrics) init(group, name, addr string) {
cm.readCalls = metrics.NewCounter(fmt.Sprintf(`%s_read_calls_total{name=%q, addr=%q}`, group, name, addr))
cm.readBytes = metrics.NewCounter(fmt.Sprintf(`%s_read_bytes_total{name=%q, addr=%q}`, group, name, addr))
cm.readErrors = metrics.NewCounter(fmt.Sprintf(`%s_errors_total{name=%q, addr=%q, type="read"}`, group, name, addr))
cm.readTimeouts = metrics.NewCounter(fmt.Sprintf(`%s_read_timeouts_total{name=%q, addr=%q}`, group, name, addr))
cm.writeCalls = metrics.NewCounter(fmt.Sprintf(`%s_write_calls_total{name=%q, addr=%q}`, group, name, addr))
cm.writtenBytes = metrics.NewCounter(fmt.Sprintf(`%s_written_bytes_total{name=%q, addr=%q}`, group, name, addr))
cm.writeErrors = metrics.NewCounter(fmt.Sprintf(`%s_errors_total{name=%q, addr=%q, type="write"}`, group, name, addr))
cm.writeTimeouts = metrics.NewCounter(fmt.Sprintf(`%s_write_timeouts_total{name=%q, addr=%q}`, group, name, addr))
cm.closeErrors = metrics.NewCounter(fmt.Sprintf(`%s_errors_total{name=%q, addr=%q, type="close"}`, group, name, addr))
cm.conns = metrics.NewCounter(fmt.Sprintf(`%s_conns{name=%q, addr=%q}`, group, name, addr))
}
type statConn struct {
// Move atomic counters to the top of struct in order to properly align them on 32-bit arch.
// See https://github.com/VictoriaMetrics/VictoriaMetrics/issues/212
closeCalls uint64
net.Conn
cm *connMetrics
}
func (sc *statConn) Read(p []byte) (int, error) {
n, err := sc.Conn.Read(p)
sc.cm.readCalls.Inc()
sc.cm.readBytes.Add(n)
if err != nil && err != io.EOF {
if ne, ok := err.(net.Error); ok && ne.Timeout() {
sc.cm.readTimeouts.Inc()
} else {
sc.cm.readErrors.Inc()
}
}
return n, err
}
func (sc *statConn) Write(p []byte) (int, error) {
n, err := sc.Conn.Write(p)
sc.cm.writeCalls.Inc()
sc.cm.writtenBytes.Add(n)
if err != nil {
if ne, ok := err.(net.Error); ok && ne.Timeout() {
sc.cm.writeTimeouts.Inc()
} else {
sc.cm.writeErrors.Inc()
}
}
return n, err
}
func (sc *statConn) Close() error {
n := atomic.AddUint64(&sc.closeCalls, 1)
if n > 1 {
// The connection has been already closed.
return nil
}
err := sc.Conn.Close()
sc.cm.conns.Dec()
if err != nil {
sc.cm.closeErrors.Inc()
}
return err
}