Expose both the HIMN network and any VIFs associated with the HIMN
network using XenCenter when the "View->Show Hidden Objects" option
is displayed. However the shown HIMN should not be able to autoplug,
edit or delete.
Changed the ellipsise length from 45 to 90 characters. This means that the first row of text becomes variable length, so I've reworked the dialog to support this and work like others: icon/rows of text in table cells, right aligned flow panel for buttons.
Signed-off-by: Callum McIntyre <callumiandavid.mcintyre@citrix.com>
- Immediately complete the ParallelAction when there are no subactions to be executed, to avoid on infinite lock while waiting for the actions to be completed.
Signed-off-by: Mihaela Stoica <mihaela.stoica@citrix.com>
- When building the list of servers that require post-install actions, ignore the ones where the patch has already been installed.
- Also fixing the infinite recursion in Build() method (causing StackOverflowException when installing a supplemental pack).
Signed-off-by: Mihaela Stoica <mihaela.stoica@citrix.com>
This fixes the NullReferenceException that occurs when trying to evacuate a host after a non-livepatch update (that requires reboot) has been installed
Signed-off-by: Mihaela Stoica <mihaela.stoica@citrix.com>
The truncating of the custom field name by space (instead of ellipsising) seems to be a Windows default, but it's not ideal. This change edits the text displayed in the dropdown when an item is selected so that if a custom field is selected it is ellipsised to an appropriate length. It doesn't affect the dropdown itself, which continues to display the full custom field name.
Making the requested changes: Name is now sorted by the generic CompareTo method (which uses name with opaque ref as tiebreaker), and Description also uses opaque ref as tiebreaker for consistency.
XenCenter will check host.patches_requiring_reboot when a host restart is due while a batch update is in progress. If the restart is not required, XenCenter will skip relevant PlanActions.
The intention here is to check this whenever a restart is due according to the original schedule - this way a completely livepatchable update can prevent the restart while the key batch hotfixing logic is not changed.
Signed-off-by: Gabor Apati-Nagy <gabor.apati-nagy@citrix.com>
Change the sorting on the Name and Description columns to use StringUtility.NaturalCompare, which correctly sorts strings with numbers at the end (eg name, name0, name1, name2, name10 will now sort correctly while alphabetic sorting is incorrect). Also added a tie break on uuid to make sorting behave predictably with duplicates in these columns.
other than strings. Moved settings of the FullScreenForm from the VNCTabView to
the former class. The FullScreenFormof the VNCTabView is only initialised as
FullSCreenFrom so no casts are necessary. The FullScreenForm is responsible for
updating the connection bar text with the value obtained from the vncScreen everytime
the name of the connection changes. Also reduced visibility of certain members.
Signed-off-by: Konstantina Chremmou <konstantina.chremmou@citrix.com>
to be shown. It is complicated to have the one control call a method in the other
which checks the state on the first control.
Signed-off-by: Konstantina Chremmou <konstantina.chremmou@citrix.com>
If we are expecting to live patch, but at the end
hosts.patches_requring_reboot contains the patch, then warn the user that
live patching has failed for the host - and it needs to be rebooted.
Signed-off-by: Callum McIntyre <callumiandavid.mcintyre@citrix.com>
Intermediate checkin. Currently has fake functionality, will always claim every involved host requires a reboot. If one host, uses ThreeButtonDialog to offer to reboot it, else uses a new RebootHostsDialog to let the user choose which, if any, to reboot. Uses the progress bar + log already on the page, which is probably the wrong design but works for now.
Signed-off-by: Callum McIntyre <callumiandavid.mcintyre@citrix.com>