* Refactored the VIFDialog to fix various problems:
- Launch the dialog in using blocks.
- Event GotFocus is not meant to be handled directly in the code.
- Populate the dialog in the OnLoad override instead of the constructor
as this causes problems at design time.
- Popping up an error message for duplicate MAC on combobox item
selection or textbox text change is not optimal UX. Perform this
check once when closing the form. Additionally the parent form of the
pop up should be the dialog, not the main window.
- The validation messages are not obvious to the user because they are
hidden in the tooltip of a disabled button. Show them inline instead.
- There is no need to create commands for VIF creation/change; use
the relevant actions instead.
Signed-off-by: Konstantina Chremmou <konstantina.chremmou@citrix.com>
* Corrections as per code review plus some more code tidy and refactoring.
- Added option to suppress Create/DeleteVIFActions
- Use property RebootRequired to indicate hot-plugging is unavailable
(assigning various objects of different types to the Result of the action
during its run may cause confusion).
Signed-off-by: Konstantina Chremmou <konstantina.chremmou@citrix.com>
- On the dialog show the next run time in both the client's and the server's local time zone.
- On the VMSS frequency page allow the user to pick the schedule in the client's
local time zone and show then next run time in both the client's and the server's local time zone.
- Refactoring to fix workflow and class design, reduce amount of code and simplify logic.
- Various layout improvements.
Signed-off-by: Aaron Robson aaron.robson@citrix.com
Signed-off-by: Konstantina Chremmou <konstantina.chremmou@citrix.com>
- When asserting if a VM can be migrated to a pool we don't have to check all the hosts in the pool at this point, we can enable the pool when we find the first host where migration is possible; we will check the rest of the hosts only if that pool is selected.
- If the destination pool is older than the source, then we don't need to do any server calls because we know that migration to an older host is not allowed.
Signed-off-by: Mihaela Stoica <mihaela.stoica@citrix.com>
- hide the boot mode control if there is only one option (BIOS boot);
- add text "(experimental)" to the experimental options (in the radio button text);
- if an option is disabled, then hide the experimantal warning, as there is already a note saying why it is disabled;
- more detailed experimental warning.
Signed-off-by: Mihaela Stoica <mihaela.stoica@citrix.com>
Thsi fixes the bug where XenCenter shows connection failure in the RPU when retrying an upgrade
Signed-off-by: Mihaela Stoica <mihaela.stoica@citrix.com>
of the hosts to be upgraded and not only on the first one in the list.
For this purpose, the test has been moved to the prechecks, and the
failures are now shown as a non-fixable problem.
Further, specification of the network location of the installer files
has moved closer to the upgrade mode selection.
Also, moved the hotfix and upgrade related checks immediately after the
host liveness check.
Signed-off-by: Konstantina Chremmou <konstantina.chremmou@citrix.com>
Moved these errors to the FriendlyNames, which is reserved for resources with
keys coming verbatim from the server.
Some code efficiency corrections to the page's workflow.
Signed-off-by: Konstantina Chremmou <konstantina.chremmou@citrix.com>
because it only manages friendly names; moved it closer to the relevant resource files.
Signed-off-by: Konstantina Chremmou <konstantina.chremmou@citrix.com>
* CP-30335: Fix RPU wizard tests
* CP-30335: Add abstract class WarningWithMoreInfo and use it for two of the existing Warnings
* CP-30335: Add a new precheck which produces a warning if the Dom0 memory after the upgrade will be increased.
- if the Dom0 memory after the upgrade is known, then a warning is shown if this is higher than the current memory, regardless of the version of the upgrade
- if the Dom0 memory after the upgrade is not known (e.g. because the rpu plugin does not have the function that returns this), then a warning is shown if upgrading from a pre-Naples version
* CP-30335: Add a more detailed error message if the host evacuation fails due to not enough memory in the RPU and Patching wizards
* CP-30335: Add branding variable for version 8.0
Signed-off-by: Mihaela Stoica <mihaela.stoica@citrix.com>
- Moved Install Location (RollingUpgradeWizard_SelectInstallMethod) page immediatelly after the Upgrade Mode page (and before the Prechecks page)
- Added a new page, called Extras, which contains the updates and supp pack installation options. These options have been moved here from the "Upgrade Mode" and "Ready To Upgrade" pages. This page is also inserted before the Prechecks
- There is no "Ready To Upgrade" page anymore. So the wizard pages are:
- when automatic mode is selected: Before You Start, Select Pools, Upgrade Mode, Installer Location, Extras, Prechecks, Apply Upgrade.
- when manual mode is selected: Before You Start, Select Pools, Upgrade Mode, Extras, Prechecks, Apply Upgrade.
Signed-off-by: Mihaela Stoica <mihaela.stoica@citrix.com>
or upgrade process (either when cancelling the wizard itself or when exiting
the application). Rephrased confirmation message for clarity.
Signed-off-by: Konstantina Chremmou <konstantina.chremmou@citrix.com>
(either when cancelling the wizard itself or exiting the application).
Implemented in the first instance for compiling the server status report.
Signed-off-by: Konstantina Chremmou <konstantina.chremmou@citrix.com>
- removal of the SystemStatusAction launching the individual SingleHostStatusActions,
because the connection was set incorrectly to the last one of the selected
connections and, if an error occurred to that connection, the data collection
for all of them failed.
- proper handling of HTTP.CancelledExceptions.
- replacement of the FlickerFreeListBox by the more versatile DataGridViewEx.
- corrections to reporting progress for individual hosts as well as page totals.
- made collection of client side data more obvious.
Signed-off-by: Konstantina Chremmou <konstantina.chremmou@citrix.com>
set by the caller. Test corrections so they don't time out due to blocking
open dialogs. Some tidying up.
Signed-off-by: Konstantina Chremmou <konstantina.chremmou@citrix.com>
Since we support checkpoint of Nvidia VGPU dedicated VMs, the conditions
text when new a VMSS needs to be refined.Note that Intel and AMD dedicated
GPUs VMs still be blocked for checkpoint.
Signed-off-by: Min Li <min.li1@citrix.com>
* Simplification: use auto-properties.
* Removed unnecessary null check. Converted private methods to linq method chain.
* Removed unused file. Added null check.
* Corrected property names as it was difficult to distinguish between the alert,
the patch and the filepath.
* Removed duplicate lock.
* CA-296490: Rewrote the logic uploading single updates so as to facilitate uploading to multiple pools in parallel.
* Corrections as per code review.
* Account for the case of uploading from disk legacy updates that do not correspond to an update alert.
Removed unfriendly error messages (the failure is written out in the logs anyway).
* Wizard test corrections and some modernising:
- Only call cancel on the last page if the test allows us to.
- Do finish the UpdatesWizard test.
- Finish the RunWizardKeyboardTests using key strokes instead of button clicks.
- Ensure the Cancel/Previous buttons do not have focus when sending an Enter stroke.
- Use optional parameters in the WizardTest constructor and string interpolation.
* Renamed badly named property.
* Improved code cloning VMs by assigning new opaque_refs to cloned VBDs.
Compacted test object provider: use optional parameters instead of method overloads.
* Modifications to prevent multiple update of enabled state and ensure the wizard
buttons are updated last.
Signed-off-by: Konstantina Chremmou <konstantina.chremmou@citrix.com>
Use two separate feature flags, `guefi` and `guefi-secureboot`, with the following rules:
- If the feature is disabled, then the option is hidden in XenCenter.
- If the feature is enabled and experimental, then the option is visible and a warning is displayed in XenCenter (in the New Vm and Import wizards).
Also show the reason why a boot mode option is greyed out (when the uefi/uefi-secure boot mode is not supported in the selected template).
(On the Page_InstallationMedia control, I moved the BootModeContol and PvBootBox controls inside the TableLayoutPanel, to allow better alignment and for better visibility in the design mode)
Signed-off-by: Mihaela Stoica <mihaela.stoica@citrix.com>
- In the New VM wizard, the boot mode control is only visible for Naples or greater hosts
- In the Import wizard, I had moved the boot mode options to a separate page, added after the target selection page, to allow the version check. The new "Boot options" page is only added for Naples or greater hosts.
Signed-off-by: Mihaela Stoica <mihaela.stoica@citrix.com>
* CP-29856: Support minimum number of vCPUs in guest templates
- Show a warning if the user wants to set a smaller number of vCPUs than the minimum specified in the template
- Add a null check; Set the warning label text before making it visible to avoid flickering.
Signed-off-by: Mihaela Stoica <mihaela.stoica@citrix.com>
If, for example, the host was disconnected, poolUpdateFromHost was null,
which was causing a silent exception resulting to an empty precheck list
shown on the page.
Signed-off-by: Konstantina Chremmou <konstantina.chremmou@citrix.com>