* CP-30335: Fix RPU wizard tests
* CP-30335: Add abstract class WarningWithMoreInfo and use it for two of the existing Warnings
* CP-30335: Add a new precheck which produces a warning if the Dom0 memory after the upgrade will be increased.
- if the Dom0 memory after the upgrade is known, then a warning is shown if this is higher than the current memory, regardless of the version of the upgrade
- if the Dom0 memory after the upgrade is not known (e.g. because the rpu plugin does not have the function that returns this), then a warning is shown if upgrading from a pre-Naples version
* CP-30335: Add a more detailed error message if the host evacuation fails due to not enough memory in the RPU and Patching wizards
* CP-30335: Add branding variable for version 8.0
Signed-off-by: Mihaela Stoica <mihaela.stoica@citrix.com>
or upgrade process (either when cancelling the wizard itself or when exiting
the application). Rephrased confirmation message for clarity.
Signed-off-by: Konstantina Chremmou <konstantina.chremmou@citrix.com>
(either when cancelling the wizard itself or exiting the application).
Implemented in the first instance for compiling the server status report.
Signed-off-by: Konstantina Chremmou <konstantina.chremmou@citrix.com>
* Simplification: use auto-properties.
* Removed unnecessary null check. Converted private methods to linq method chain.
* Removed unused file. Added null check.
* Corrected property names as it was difficult to distinguish between the alert,
the patch and the filepath.
* Removed duplicate lock.
* CA-296490: Rewrote the logic uploading single updates so as to facilitate uploading to multiple pools in parallel.
* Corrections as per code review.
* Account for the case of uploading from disk legacy updates that do not correspond to an update alert.
Removed unfriendly error messages (the failure is written out in the logs anyway).
* Wizard test corrections and some modernising:
- Only call cancel on the last page if the test allows us to.
- Do finish the UpdatesWizard test.
- Finish the RunWizardKeyboardTests using key strokes instead of button clicks.
- Ensure the Cancel/Previous buttons do not have focus when sending an Enter stroke.
- Use optional parameters in the WizardTest constructor and string interpolation.
* Renamed badly named property.
* Improved code cloning VMs by assigning new opaque_refs to cloned VBDs.
Compacted test object provider: use optional parameters instead of method overloads.
* Modifications to prevent multiple update of enabled state and ensure the wizard
buttons are updated last.
Signed-off-by: Konstantina Chremmou <konstantina.chremmou@citrix.com>
If, for example, the host was disconnected, poolUpdateFromHost was null,
which was causing a silent exception resulting to an empty precheck list
shown on the page.
Signed-off-by: Konstantina Chremmou <konstantina.chremmou@citrix.com>
If the update sequence for automated updates contains an update which requires a host reboot and a hotfix with an immediate toolstack restart (after-apply-guidance=restartXAPI and guidance-mandatory=true),
then XenCenter should do an immediate host reboot after applying the hotfix that required the immediate toolstack restart (as doing a toolstack restart when a host reboot is required is potentially risky)
Signed-off-by: Mihaela Stoica <mihaela.stoica@citrix.com>
lost when leaving and returning back to the SelectServers page.
Also, the list of SelectedServers does not need to be re-evaluated every time
it is accessed but rather once when we move away from the page.
Signed-off-by: Konstantina Chremmou <konstantina.chremmou@citrix.com>
Also, simplified the logic selecting the single update when we leave the
SelectPatchPage so as to avoid ambiguities in which properties are to be set
and refactored the error handling methods to avoid duplicate checks and
provide the right error message (for example, the error message was misleading
for a non-existent path; or, the level of detail provided in the case of
invalid zip content was of lesser relevance to the user).
Signed-off-by: Konstantina Chremmou <konstantina.chremmou@citrix.com>
legacy patch and then went back to select and install an update.
The code was removing all the uploaded legacy patches except the installed
ones. In this case the installed legacy patch is null hence all the already
uploaded patches need to be removed.
Signed-off-by: Konstantina Chremmou <konstantina.chremmou@citrix.com>
* CP-29768: Add Skip functionality for RPU supp pack installation
Signed-off-by: Ji Jiang <ji.jiang@citrix.com>
* Minor corrections
Signed-off-by: Mihaela Stoica <mihaela.stoica@citrix.com>
* Revert unnecessary layout changes
Also changed the title of the confirmation dialog to the wizard title, as it could be shown in either RPU or the Patching wizard
Signed-off-by: Mihaela Stoica <mihaela.stoica@citrix.com>
the Prechecks page, then back to select a single iso update, and forwards again
to the Prechecks page. The cause was that the values of Patch and PoolUpdate
were not always propagated from the Upload page to the following pages, hence
on that occasion they were both non-null, while the logic of the following
pages expects only one of the two to be non-null.
Signed-off-by: Konstantina Chremmou <konstantina.chremmou@citrix.com>
One of the PatchGridViewRow constructors was obsoleted, hence the _image and
_status cells and the row's PathPatch were always null. When a user selected a
patch, moved to the Prechecks page, back to the Select page, and the host got
disconnected, on moving to the SelectServers page and closing the warning pop-up,
XenCenter crashed because it was trying to update details of null cells. Also,
removed obsoleted toggling expanded state functionality.
Signed-off-by: Konstantina Chremmou <konstantina.chremmou@citrix.com>
With this change, following are working:
1) After applying XS75E003-5 only restart host, no restart toolstack
2) After applying vGPU driver on 7.4, restart host happens
Signed-off-by: Ji Jiang <ji.jiang@citrix.com>
* CA-293776: The order in which a single update is applied on the slaves is not the same as the order in which they are displayed
Apply the same Hosts sorting rules for all the PatchingWizard Pages .
Signed-off-by: Tim Liu <tim.liu@citrix.com>
* CA-293776: The order in which a single update is applied on the slaves is not the same as the order in which they are displayed
Place orderby clause after where clause
Signed-off-by: Tim Liu <tim.liu@citrix.com>
* CA-293813: Patch pools in parallel when installing a single update/patch or supplemental package.
Signed-off-by: Konstantina Chremmou <konstantina.chremmou@citrix.com>
* Corrections as per code review.
Signed-off-by: Konstantina Chremmou <konstantina.chremmou@citrix.com>
* CA-292626: Consider the contains-livepatch flag of all the applicable updates when doing the prechecks in the automated updates mode.
Instead of looking at the minimal patches, we look at all applicable patches for that host (i.e. all the updates on the host's version that are not already installed) and we say that the host won't need a reboot only if all these are marked as contains-livepatch.
Signed-off-by: Mihaela Stoica <mihaela.stoica@citrix.com>
* CA-293854: Patching wizard updates list loses selection and resizes columns when resorted
Remove the redundant code
Change the AutoSize mode from DisplayedCells to AllCells.
Fix the date column sorting
Disable column header AutoSizing
Signed-off-by: Tim Liu <tim.liu@citrix.com>
* CA-284914: Prechecks are re-run every time the 'Hide successful prechecks' is ticked/unticked
Signed-off-by: Jisheng Xing <jisheng.xing@citrix.com>
* fix some comments
or Host accordingly. Extended comparison of Problems to also take account of
the XenObject the Check was performed on, otherwise the Problems get mixed
up when there are homonymous members across pools.
Signed-off-by: Konstantina Chremmou <konstantina.chremmou@citrix.com>
* CP-28431: Block updates and upgrades from Kolkata onwards if clustering enabled
* CP-28431: Rename files and change from Pool Check to [Host] Check
* CP-28431: Change description message
Signed-off-by: Seren Corbett <seren.corbett@citrix.com>
on the update mode, so that the right set of hosts is passed on to the prechecks
page for partially upgraded pools that are to be updated to a new version with
hotfixes. Also, corrected code that was mixing the logic of changing the enabled
state of a row with the checked state.
Signed-off-by: Konstantina Chremmou <konstantina.chremmou@citrix.com>
Also sort Messages.resx and call ReplaceProgressStep instead of AddProgressStep in the DownloadPatchPlanAction class (when the download is skipped)
Signed-off-by: Mihaela Stoica <mihaela.stoica@citrix.com>