- We shouldn't include the hidden SRs in the list of available SRs in the Migration wizard
- Updated the SR.SupportsVdiCreate function to return false for the Memory SR; this fixes other places where the Memory SR might be visible (e.g. all places where SrPicker is used)
- Also fixed the same issue in the Attach disk dialog
Signed-off-by: Mihaela Stoica <mihaela.stoica@citrix.com>
Using new XAPI functionality in Install Update Wizard required by the new packaging format (ISO updates)
Signed-off-by: Gabor Apati-Nagy <gabor.apati-nagy@citrix.com>
PVS Tab:
- Move the "View PVS sites" button inside the "Configure PVS Cache" dialog (next to Remove button) and make it per-site (showing only the PVS servers from that site)
- Remove "Currently attached" column from the VMs section
- Rename "Status" column to "Read caching status"
Configure PVS Cache" dialog:
- Make sure there is a scrollbar to accommodate all hosts in a pool
- Add a confirmation dialog when a site is removed. The action is executed when the Remove button is pressed.
- When Memory SR is selected, set the maximum value to the dom0-extra-memory..
- Allow empty configuration (but see next point): The OK button should only be disabled if the PVS site name is empty
- Add an extra option in the "Cache storage" combobox, with text "Not configured", selected by default on a new site. When this is selected, we will remove the existing entry in pvs_cache_storage and will not create a new one.
- When a PVS site is deleted (forgotten), we first delete all the associated PVS_servers, otherwise the site cannot be deleted.
- Allow move of multiple VDIs
- CA-187659: show better messages when batching move/migration of multiple VDIs.
- Show different tooltips for single vs. multiple VDI move/migration/deletion.
- Refactored the MoveDiskDdialog. Removed the inherited class VDIMigrateDialog and
the batching manager as it was not very different from its parent, it was registering
the events twice, and was batching migration of even single VDIs.
- Tidied up the Move- and MigrateVirtualDisk commands so they're easier to compare.
Signed-off-by: Konstantina Chremmou <konstantina.chremmou@citrix.com>
* CP-16922: UI changes to PvsPage to replace the single configure button with a separate enable and disable one, per the design doc
* CP-16922: Intermediate checkin - command + dialog implemented, but PVS page has some layout problems.
* CP-16922: Implement GUI for enabling PVS read caching and marking/unmarking VMs for prepopulation
Fix the broken layout by reverting MainWindow.resx (which shouldn't have changed) back to the previous commit. Also removed duplicate properties button code.
* CP-16922: PVS Page changes, to properly display all VMs (not just ones with proxy), only populating proxy columns if there is a proxy set.
* CP-16922: Use a CommandButton for the enable button, connected to the same command as the VM main menu button, and using the table selection as its selection manager.
* CP-16922: Delete the old enable button click behaviour (because it now has a proper command), was causing the dialog to show up twice
* CP-16922: Properly list VMs by hiding those that should be hidden (in addition to non-VMs, also hide the __gui__ prefix and others covered by Show function). Also fixes a bug in NewVMGroupVMsPage discovered when fixing this - it would show VMs that should be hidden if you used the search bar.
* CP-16922: Use ButtonText on the Command to set the text on the PVS enable button
* CP-16922: Add the disable PVS read-caching command, and its associated proxy destroy action. Both based off enable equivalents (main difference is no dialog for now). Not used yet but will be in main window menu + disable button
* CP-16922: Add disable PVS read-caching to the main window menu (under enable), with the disable command attached to it
* CP-16922: Add support for disabling PVS read-caching for selected hosts via the PVS tab page by converting the disable button into a CommandButton in the same way as the enable button, using its own command + selection manager (because Selection Managers only bind to one control)
* CP-16922: Design - adding the "read caching enabled" column from the design, so that we display both whether caching is enabled and whether the VM is currently cached. If it's disabled all other values are missing.
* CP-16922: Add the PVS site column per the design to show the site a VM's PVS Proxy is on if it has a proxy
* CP-16922: Add an event handler for VMs changing so that newly provisioned VMs immediately show up in the PVS tab page
* CP-16922: Support for properly remembering the selection when the VM list is refreshed. A new method returns the list of VMs for the selected rows, and we can then check if the VM for the row being added is in this list. If there was no previous selection then we still select the first row by default.
* CP-16922: Remove prepopulate, which is being removed from the design. The next XAPI version will remove it, so just pass False as prepopulate for now, and remove the option from the dialog and PVS tab page.
* CP-16922: Improve UI appearance for a missing Storage Repository. Per the design, if there is no SR show the message None (memory only) instead of an empty cell
* CP-16922: Improved sorting behaviour. All columns (except VM name, which always uses it) use the VM tag as a sorting fallback (since they all have duplicates). New default sort which sorts by caching enabled first (yes before no), and then VM tag as a tiebreaker. Support for remembering the current sort on refresh, ie when a value changes.
* CP-16922: Refactoring to use a VM extension method to get the PVSProxy (or null if none exists) for a VM. This was used in the PVS Page + commands which are now much simpler.
* CP-16922: Move where the SelectionChanged event handler is set when refreshing the PVS table, so that the command buttons are updated correctly.
* CP-16922: Improvements to PVS read-caching dialog. Set accept/cancel buttons properly + adjust tab values, so focus acts as expected
* CP-16922: Remove the images from the menu for Enable/Disable PVS read-caching, most commands in the menu don't have one
* CP-16922: Sorting out the strings for the actions + ParallelAction calls, and moving them into the resx. Also reverting wrong MainWindow.resx changes.
* CAR-2184: XAPI changes. I've made the minimal possible changes to PvsPage to ensure it compiles, but it's had a lot of feature work (CP-16922) that supersedes this, these small changes should keep that merge painless.
* CAR-2184 XAPI: Reverse the unrelated changes, only keep the PVS ones.
* CP-16922: Merge latest XAPI changes, notably changes to Pvs_site.create
* CP-16922: Change tab show/hide logic for PVS tab, show it even if there are no PVS sites.
* CP-16922: Implement GUI for enabling PVS read caching
Design changes - remove the storage repo column and replace it with status, which is populated with a friendly version of the pvs_proxy_status enum. Also populate site list using site.name_label
Signed-off-by: Callum McIntyre <callumiandavid.mcintyre@citrix.com>
* CP-16922: Implement GUI for enabling PVS read caching
Adjusting the CanExecute of Enable PVS read-caching command to require at least one PVS site to be created. Since the PVS tab can show up without any sites, we need this because we can't create a proxy without a site.
* CP-16922: Code review changes.
Tidied up messages, and ensured actions run async properly, and without exiting before their task.
* CP-16922: Code review changes.
Update dialog resx, wider combobox on dialog, update action descriptions before setting RelatedTask, add friendly message body for PVS error notifications.
* CAR-2184: XAPI changes. I've made the minimal possible changes to PvsPage to ensure it compiles, but it's had a lot of feature work (CP-16922) that supersedes this, these small changes should keep that merge painless.
Signed-off-by: Callum McIntyre <callumiandavid.mcintyre@citrix.com>
* CAR-2184 XAPI: Reverse the unrelated changes, only keep the PVS ones.
Signed-off-by: Callum McIntyre <callumiandavid.mcintyre@citrix.com>
Expose both the HIMN network and any VIFs associated with the HIMN
network using XenCenter when the "View->Show Hidden Objects" option
is displayed. However the shown HIMN should not be able to autoplug,
edit or delete.
- when the cd drive or the tools iso cannot be found, the action should fail.
- if the tools SR is broken, do not show the error on a pop-up because the UX is
bad when installation is attempted on multiple VMS.
- added one more entry to the list of possible tools iso names.
- small performance improvement.
Signed-off-by: Konstantina Chremmou <konstantina.chremmou@citrix.com>
This means that if license_params doesn't contain this key we consider it restricted.
Signed-off-by: Callum McIntyre <callumiandavid.mcintyre@citrix.com>
- Added Control Domain memory entry in the host memory control on Memory tab.
- Control domain memory is editable for Ely and greater hosts.
- Can be changed from a dialog that requires host to be in maintenance mode and triggers a host reboot after the memory is changed.
- This dialog is available from Server main menu and from the host memory tab.
- Also removed unused unit controls on host and VM memory bars.
Signed-off-by: Mihaela Stoica <mihaela.stoica@citrix.com>
Removed unused properties.
Added new string resource to set the pvs farm dialog's title.
Extended XenAPI's PVS_farm class to override Name property to allow for simpler sorting code.
Removed embedded icon in resource file; dialog now inherits the application's icon.
Signed-off-by: Frezzle <frederico.mazzone@citrix.com>
- tab visible on pool or standalone server if the feature is not restricted and the pools has at least one farm
Signed-off-by: Mihaela Stoica <mihaela.stoica@citrix.com>
- For Dundee and newer hosts: the feature is restricted only if the "restrict_ssl_legacy_switch" flag exists and it is set to true
- For pre-Dundee hosts: the feature is restricted if the "restrict_ssl_legacy_switch" is absent or it is present and set to true
Signed-off-by: Mihaela Stoica <mihaela.stoica@citrix.com>
VM with the hci-warn-before-shutdown flag. Minor changes to make the warnings for
rebooting and shutting down more consistent (preselect the No button for rebooting;
extended the Yes button text; modified warning text)