Mostly just terminology changes from home server to target server in the CPM wizard. Changes in shared component SelectMultipleVMDestinationPage (shared with ImportWizard) to allow CPM wizard to rename the Home Server column (as it can the VM/template one - using the same pattern).
Signed-off-by: Callum McIntyre <callumiandavid.mcintyre@citrix.com>
- changes to the text to be suitable for migrate and copy operations, where possible
- added different text for copy on some pages
- also different text for single and multiple selection
- changes to text alignment, tab order, hotkeys on the copy pages
- removed Finish page from the intra-pool copy wizard
Signed-off-by: Mihaela Stoica <mihaela.stoica@citrix.com>
We observed that some threads can reach deadlock-ish state after they have Invoked into a control's UI thread. When it happens they are all in a waiting for join or in sleep state for very long time, although there should not be any deadlock situations.
It seems this has something to do with multiple parent controls and with which control we invoked on. This should not make a difference, because we have got one UI thread (for MainWindow) they should wait for, but we have seen it does.
The solution that fixed this issue was to invoke on the MainWindow instead of various controls (see a4fe507adf ).
This changeset is changing all our Invokes to invoke into MainWindow
instead of a control itself. (MainWindow's UI thread is the only UI thread
all Control is using in XenCenter)
This changeset should be in place until we have found the root cause or the exact reason for the above.
- before leaving each page of the wizard, check if all selected VMs are still available for migration
Signed-off-by: Mihaela Stoica <mihaela.stoica@citrix.com>