- Memory Tab uses GB units for values greater or equal to 1 GB, otherwise show in MB;
- Search Tab displays values in GB or MB in the same as the Memory Tab (e.g. 512 MB of 1 GB, 256 MB of 512 MB, 2.5 GB of 16 GB).
- The shiny bar present in the Memory Tab and in Memory Settings dialog shows the scaling in the following way: If smaller than 1 GB, then show as before, else show only labels with values multiples of half a GB.
- The units used in Memory Setting Dialog are set depending on the static_max. If it is greater or equal to 1 GB, then the units are GB, else MB. The user does not have the possibility of changing them.
We observed that some threads can reach deadlock-ish state after they have Invoked into a control's UI thread. When it happens they are all in a waiting for join or in sleep state for very long time, although there should not be any deadlock situations.
It seems this has something to do with multiple parent controls and with which control we invoked on. This should not make a difference, because we have got one UI thread (for MainWindow) they should wait for, but we have seen it does.
The solution that fixed this issue was to invoke on the MainWindow instead of various controls (see a4fe507adf ).
This changeset is changing all our Invokes to invoke into MainWindow
instead of a control itself. (MainWindow's UI thread is the only UI thread
all Control is using in XenCenter)
This changeset should be in place until we have found the root cause or the exact reason for the above.
- When deciding whether to allow GPU configuration on a VM, check if the HA is enabled, not just the the VM's restart priority setting
Signed-off-by: Mihaela Stoica <mihaela.stoica@citrix.com>
-We used to check host.RestrictVgpu instead of checking the API version when populating the dropdown on the GPU Settings page. This is not sufficient anymore as it depends on the license too, so changed the code to check version (vGPU was introduced in Clearwater SP1).
- changes following code review: simplified the code that determines the current state; and renamed some variables.
Signed-off-by: Mihaela Stoica <mihaela.stoica@citrix.com>
- Added a "Integrated GPU passthrough" section to the PoolGpuEdit page.
- This section is only visible for a host that has GPU capability and the enabling/disabling of integrated GPU passthrough is not restricted.
- With this addition, the GPU page can now be displayed for a pooled host as well (previously only pool or standalone host)
Signed-off-by: Mihaela Stoica <mihaela.stoica@citrix.com>
- this applies to the Cloud-config page on the New VM Wizard and VM properties dialog.
- same for the container enlightenment page on the VM properties dialog.
Signed-off-by: Mihaela Stoica <mihaela.stoica@citrix.com>
New Page: Enlightenment on VM Properties Dialog, visible only for:
- VMs on Cream Or Greater hosts
- that can be enlightened, regardless of their power state
A VM can be enlightened if the key "xscontainer-monitor" exists in other_config.
A VM is enlightened if other_config:xscontainer-monitor if true.
Signed-off-by: Mihaela Stoica <mihaela.stoica@citrix.com>
Fix the following display issues:
1. Should leave more space upon pool granularity setting with XenCenter Chinese version.
2. "Close" should not be the default button when "Previous Section" or "Next Section" is enabled.
3. On WLB advanced settings page, the split line of pool audit granularity should extend and contract along with the size change of the form.
4. For large pool audit trail report, click "Next Section" till the report end, if change user/object/startdate/enddate, "Run Report" button is shown but disabled. Should enable it.
Signed-off-by: Hui Zhang <hui.zhang@citrix.com>