- Improvements to progress reporting (CA-65894).
- Added some logging.
- Use the connection cache instead of making server calls.
- Moved some methods to the string utilities and added unit tests.
Signed-off-by: Konstantina Chremmou <konstantina.chremmou@citrix.com>
Previously this was not possible due to XenModel-XenOvfTransport cyclical references.
Signed-off-by: Konstantina Chremmou <konstantina.chremmou@citrix.com>
The result was that numbers were changing suddenly; in cases of slow connections,
a user could make a selection before the scan was over.
Signed-off-by: Konstantina Chremmou <konstantina.chremmou@citrix.com>
- Handle validation for OVF files with a name different from the containing
OVA package. Other corrections to wrong validation logic.
- Show validation warnings on a dialog that can be turned off.
- Clean up extracted files after an OVA package has been imported.
- Plus code refactoring and simplification.
Signed-off-by: Konstantina Chremmou <konstantina.chremmou@citrix.com>
- Fixed button enablement on the IntraPoolCopy page.
- Regression on the NewDiskDialog were selection was considered valid
even if the SR was disabled.The SrSelectionChanged and SelectedIndexChanged
were fired in the wrong order. To fix this the event SrSelectionChanged
is removed (in reality after the refactoring in 5b79b1dc94
it became obsolete).
Signed-off-by: Konstantina Chremmou <konstantina.chremmou@citrix.com>
- Moved path validation checks from the wizard to its last page (planning
to remove XenWizardBase.FinishCancelled in future).
- If the directory did not exist, the user saw a message about inability
to write a file which was misleading. Check directory existence explicitly.
- Populate the last wizard page on load rather than on construction to
avoid unnecessary validations.
- Save in the settings the report output directory, not the filename.
Signed-off-by: Konstantina Chremmou <konstantina.chremmou@citrix.com>
Also, minor layout correction, and usability enhancement: do not disable
the controls under the radio button when the latter is deselected.
Signed-off-by: Konstantina Chremmou <konstantina.chremmou@citrix.com>
* CP-30958: Initial implementation of the Conversion Manager in XenCenter.
* Corrections following review and improvements.
* Further corrections and improvements.
Signed-off-by: Konstantina Chremmou <konstantina.chremmou@citrix.com>
The blurbs should be user-centric rather than developer-centric.
No need to disable the page controls in the absence of signature/manifest
since the whole page becomes disabled in that case.
Signed-off-by: Konstantina Chremmou <konstantina.chremmou@citrix.com>
- Verification of appliance files in chunks to avoid StreamTooLong exception.
- Disposal of HashAlgorithms and X509Certificates after use.
- General code simplification.
Signed-off-by: Konstantina Chremmou <konstantina.chremmou@citrix.com>
- Made storage selector blurb for XVA import a bit more informative.
- A simple checkbox for starting the new VMS on the finish page is adequate.
- Typos. Property modernisation.
Signed-off-by: Konstantina Chremmou <konstantina.chremmou@citrix.com>
- When asserting if a VM can be migrated to a pool we don't have to check all the hosts in the pool at this point, we can enable the pool when we find the first host where migration is possible; we will check the rest of the hosts only if that pool is selected.
- If the destination pool is older than the source, then we don't need to do any server calls because we know that migration to an older host is not allowed.
Signed-off-by: Mihaela Stoica <mihaela.stoica@citrix.com>
- hide the boot mode control if there is only one option (BIOS boot);
- add text "(experimental)" to the experimental options (in the radio button text);
- if an option is disabled, then hide the experimantal warning, as there is already a note saying why it is disabled;
- more detailed experimental warning.
Signed-off-by: Mihaela Stoica <mihaela.stoica@citrix.com>
(either when cancelling the wizard itself or exiting the application).
Implemented in the first instance for compiling the server status report.
Signed-off-by: Konstantina Chremmou <konstantina.chremmou@citrix.com>
Use two separate feature flags, `guefi` and `guefi-secureboot`, with the following rules:
- If the feature is disabled, then the option is hidden in XenCenter.
- If the feature is enabled and experimental, then the option is visible and a warning is displayed in XenCenter (in the New Vm and Import wizards).
Also show the reason why a boot mode option is greyed out (when the uefi/uefi-secure boot mode is not supported in the selected template).
(On the Page_InstallationMedia control, I moved the BootModeContol and PvBootBox controls inside the TableLayoutPanel, to allow better alignment and for better visibility in the design mode)
Signed-off-by: Mihaela Stoica <mihaela.stoica@citrix.com>
- In the New VM wizard, the boot mode control is only visible for Naples or greater hosts
- In the Import wizard, I had moved the boot mode options to a separate page, added after the target selection page, to allow the version check. The new "Boot options" page is only added for Naples or greater hosts.
Signed-off-by: Mihaela Stoica <mihaela.stoica@citrix.com>
- if a VM can migrate inside a pool, then we will allow it in the wizard, even if storage migration is not allowed
- If it is a intra-pool migration (without moving the disks), then use the VM migrate action (which does a VM.pool_migrate), not the cross pool migrate action.
Signed-off-by: Mihaela Stoica <mihaela.stoica@citrix.com>
* CA-301156: VM created from disk import for a UEFI VM has missing values
Set default params when importing VHD
Signed-off-by: Tim Liu <tim.liu@citrix.com>