The restriction that Storage Motion was not possible in the presence of WLB has been removed in Dundee. This commit removes the check in XenCenter.
Signed-off-by: Mihaela Stoica <mihaela.stoica@citrix.com>
Fixed issues where total initial allocation for an SR was not calculated correctly. Also some minor improvements.
Signed-off-by: Gabor Apati-Nagy <gabor.apati-nagy@citrix.com>
Creates a new function MemorySizeStringSuitableUnits that takes one more parameter that specifies the units that must be used when the number of bytes is 0.
Adds tab indexing to the control for allocation and changes label names.
Corrects mistake that led to exception being thrown when the Disk Size is decreased in the the New Disk Dialog.
- while upgrading a host, throw a HOST_OFFLINE ("Server could not be contacted") exception if the host can no longer be resolved (instead of HANDLE_INVALID)
- also corrected the parameters of the HANDLE_INVALID exception, as an extra parameter is needed for the friendly error name.
- in the UpdateManualHostPlanAction class I replaced Host with the private property _host in several places, so we are no longer trying to resolve the host each time we want to write something into logs
- added some null checks, to avoid reporting null reference exception
Signed-off-by: Mihaela Stoica <mihaela.stoica@citrix.com>
- this applies to the Cloud-config page on the New VM Wizard and VM properties dialog.
- same for the container enlightenment page on the VM properties dialog.
Signed-off-by: Mihaela Stoica <mihaela.stoica@citrix.com>
1.Add xapi version check in cream since Cream and Creedence have the same platform version
2.Check feature-ts2 to see if turn on RDP feature can use on specific VM PV tool
Signed-off-by: Cheng Zhang <cheng.zhang@citrix.com>
Changes following code review:
- Added VM.CanHaveVGpu function (at the moment just returns CanHaveGpu, but it will change in the future)
- Added vGPU_type.IsPassthrough function and used it everywhere we needed to test for passthrough (max-heads==0)
- Simplified code in Helpers.GpuCapability, Helpers.VGpuCapability, NewVMWizard (gpuCapability), MainWindow and GpuRow
Signed-off-by: Mihaela Stoica <mihaela.stoica@citrix.com>
New properties:
- Pool.HasGpu = Pool has at least one PGPU
- Pool.HasVGpu = Pool has at least one PGPU that HasVGpu
- PGPU.HasVGpu = PGPU has at least one supported_VGPU_type that is not pass-through
New or modified helper functions:
- Helpers.GpuCapability = GPU feature not restricted (by licensing) and Pool.HasGpu
- Helpers.VGpuCapability = vGPU feature not restricted (by licensing) and Pool.HasVGpu
- Helpers.ClearwaterSp1OrGreater = API version is 2.1 or greater
The GPU dialogs are displayed as follows:
- GPU page on VM properties dialog: Visible only if VM.CanHaveGpu and the GPU feature not restricted (by licensing)
- GPU page on New VM Wizard: Visible only if VM.CanHaveGpu and the pool has GPU capability (Helpers.GpuCapability)
- GPU page on Pool properties dialog: Visible only if the pool has vGPU capability (Helpers.VGpuCapability)
- GPU tab: Visible only if the pool has GPU capability (Helpers.GpuCapability) and is Clearwater SP1 or greater
- On the GPU tab, the "Placement policy" panel: Visible only if the pool has vGPU capability (Helpers.VGpuCapability)
- On the GPU tab, the "Edit" button on the "vGPU types" panel: Visible only if the PGPU.HasVGpu and vGPU feature not restricted (by licensing)
Also:
- VM.CanHaveVGpu function renamed to CanHaveGpu
- On the GPU tab, renamed "Allowed vGPU types" to "vGPU types
- The VLAN can be set to 0 only for Creedence or greater hosts on the vSwitch backend.
- When VLAN 0 is selected, an info is shown next to the control, saying "VLAN 0 will receive all traffic not on any other VLAN"
- Also fixed an error on New Network Wizard, where the "VLAN in use" message was still visible when changing the NIC.
Signed-off-by: Mihaela Stoica <mihaela.stoica@citrix.com>
Also GPU page on Pool properties dialogs should not be shown for non vGPU pools.
# HG changeset patch
# User Mihaela Stoica <Mihaela.Stoica@citrix.com>
# Date 1385743406 0
# Fri Nov 29 16:43:26 2013 +0000
# Node ID e28f9921a0a17efb1e3a8d185acf18b5b6e116b1
# Parent 59229250db34dd4cc1f34fbdab055467a1570f87
Signed-off-by: Konstantina Chremmou <konstantina.chremmou@citrix.com>
1. Added AugustaOrGreater method to Helpers class (which is preferred method over MethodExists to check if a xapi call is available on a server). Also removed MethodExists method.
2. Utilized AugustaOrGreater method in GetDRMissingSRs method in both VM and VM_appliance classes.
1. Added MethodExists method to Helpers class: this method tests wheather given method exists already.
2. Utilized new Helpers method in VM and VM_appliance classes.
3. Fixed ACTION_MULTIPLE_DR_TASK_CREATE_ messages.
Signed-off-by: Adrian Jachacy <Adrian.Jachacy@citrix.com>
been previously upgraded.
Introduced Host.LongProductVersion property which returns host's
product version and build number (e.g. 5.6.100.72258), or null if
product version can't be found. We use this property to check
if the master has been updraded and to decide which slaves need
to be upgraded or to skip hosts already upgraded.
Signed-off-by: Mihaela Stoica <mihaela.stoica@citrix.com>