-Reverted changes of CA-109242 (PR-62 on GitHub)
-Network tab: now to show '<None>' instead of '-' as Link Status (for pools: when the network has no PIFs; for hosts: when the network has no PIF )
Signed-off-by: Gabor Apati-Nagy <gabor.apati-nagy@citrix.com>
- In the Events view, offer a choice only to dismiss the visible ones instead of all
- Keep the filter buttons always enabled. This applies to all Notification views (Alerts, Updates & Events)
- Also refined the confirmation messages displayed when dismissing events
Signed-off-by: Mihaela Stoica <mihaela.stoica@citrix.com>
-Fixed by removing all the (redundant) tooltips from all the buttons in Alerts, Updates, Events view.
Signed-off-by: Gabor Apati-Nagy <gabor.apati-nagy@citrix.com>
-Fixed by removing all the (redundant) tooltips from all the buttons in Alerts, Updates, Events view.
Signed-off-by: Gabor Apati-Nagy <gabor.apati-nagy@citrix.com>
Enhance WLB pool audit trail report:
1). Update advance settings to control audit trail granularity.
2). Update pool audit trail report to add user and object lists for selection.
3). Display large pool audit trail report with sections.
4). Localization for Chinese version.
5). Compatibility with WLB 6.5 and 6.1 or before.
Signed-off-by: Hui Zhang <hui.zhang@citrix.com>
Changes to the DeleteAllAlertsAction:
- when the dismiss operation fails with INVALID_HANDLE we need to remove the alert from our alert list (XenCenterAlerts) and trigger the CollectionChanged event so that the alert count gets updated.
- the action title now says "Removing <n> alerts" when dismissing all/selected alerts and "Removing alert" when dismissing single alert (instead of "Removing all alerts" in all cases)
- move the initialization of Dismissing flag outside the action (see below)
This fix also includes changes so that the Dismissing flag works as intended: to be able to hide the dismissing alerts in the Alerts view immediately, rather than one by one when they were actually deleted, causing a large number of refreshes.
On dismissing alerts we do:
1. set dismissing to true for all alerts
2. rebuild alert list (this will filter out the dismissing alerts)
3. dismiss alerts - run the DismissAllAlerts action
Also, the action buttons on each row should only apply to the clicked row (not multiselect).
Signed-off-by: Mihaela Stoica <mihaela.stoica@citrix.com>
- The problem was the Summary page was displayed before the lists of succeeded and failed actions have been populated (on the Completed event of each action).
- To fix it, we populate these lists after all the actions are completed, and on the event thread.
Signed-off-by: Mihaela Stoica <mihaela.stoica@citrix.com>
- cannot remove completely because of the plugin specification, but it is not be visible even if they were plugins trying to use it
Signed-off-by: Mihaela Stoica <mihaela.stoica@citrix.com>
- Set the pool details in the action to allow proper filtering by location on the Events page
- Also, when possible, set the Host property: when setting the SR in the action, we also set the Host to SR.Home
Signed-off-by: Mihaela Stoica <mihaela.stoica@citrix.com>
- Suppress reporting of success and failure for sub-actions:
The suppress history flag is set when the action is created and if is false (by default) the action is added to the history (the Events list).
In order to suppress history for the subactions, we need change all actions used in Edit pages so their constructor can set the SuppressHistory flag and then use these constructors with suppressHistory = true on all the implementations of IEditPage.SaveSettings() where an action is created
(then we need to remember to do the same everytime we introduce a new page and / or "save" action).
Signed-off-by: Mihaela Stoica <mihaela.stoica@citrix.com>
-According to the call stack this is the place where the exception can come. Although I was not able to reproduce the exception, this fix solves a possible argument (index) out of range exception. With this check, point merging is not going to be done if it would be unnecessary anyway when there were an empty list to be merged (count==0).
Signed-off-by: Gabor Apati-Nagy <gabor.apati-nagy@citrix.com>
-Fixed Home server's commands to try to use both versions of migration when deciding to enable or disable the menu item
Signed-off-by: Gabor Apati-Nagy <gabor.apati-nagy@citrix.com>
- Added three Warning classes (HAEnabledWarning, WLBEnabledWarning, HostNotLiveWarning), used in the Pre-checks page of the Install wizard (also in the Rolling Pool Upgrade wizard) to indicate that a check was skipped and the reason why.
- If HA or WLB is on, we show this as an error in the "HA and WLB status" check and the "VM migration status" checks will be skipped (with a warning displayed) for all the hosts in the pool.
- Similarly, if a host if unreachable, we show this as an error in the "Host liveness status" check and the following checks for that host will be skipped (and warning displayed).
Signed-off-by: Mihaela Stoica <mihaela.stoica@citrix.com>
- Make "Reclaim freed space" a CommandButton (will appear as disabled if the command cannot execute)
- Add tooltip to "Reclaim freed space" button to show the reason it is disabled
- Hide "Reclaim freed space" button on old servers
- Allow multiselect
- "Reclaim freed space" button enabled if at least one SR can be trimmed
Signed-off-by: Mihaela Stoica <mihaela.stoica@citrix.com>
- Register a PIF CollectionChanged event, so the page is refreshed when a bond is added / deleted.
- Register the PIF PropertyChanged event to each PIF when the grid is populated; this ensures that all the PIFs displayed will be refreshed when their properties change.
Signed-off-by: Mihaela Stoica <mihaela.stoica@citrix.com>
This fixes the following problem:
When the main window is resized, we set the minimum width of the right side panel (Panel2MinSize) to half the size of the window so that the tab contents are visible. This is fine on most situations, but on a higher screen resolution (e.g. 1920x1080) the following problem occurs:
- starting with the main window at minimum size, when the window is maximized, the Panel2MinSize is set to half window's size (e.g. 960)
- when the main window is restored back to the minimum size, the split container is not resized because there is a conflict between Panel2MinSize and the size of the window itself (Panel1MinSize + Panel2MinSize > window's width)
- therefore the navigation panel is not visible and also the content of the tab control may appear out of scale.
To fix this, we set the Panel2MinSize to half of the window's minimum width. This way the right side panel will always fit in the window, including when it is restored to minimum size.
This also fixes [CA-137956] - Restoring Maximised XenCenter does not resize the main panel properly.
Signed-off-by: Mihaela Stoica <mihaela.stoica@citrix.com>
When the navigation panel is resized, we need to preserve the height of the bottom panel, by recalculating the splitter distance.
Signed-off-by: Mihaela Stoica <mihaela.stoica@citrix.com>
- Added a 'refresh grid' parameter to UpdateRow() which indicates if a sort and refresh of the grid is necessary.
- A sort and refresh is not needed when the user selects a server by pressing the space key or by mouse, but it is needed when the information displayed has changed, for example when the license has changed.
- Also solved a possible null reference exception in CheckableDataGridViewController.ReplaceStoredRow(), by returning -1 if the index is not within the rows range.
Signed-off-by: Mihaela Stoica <mihaela.stoica@citrix.com>
Force an update of the selected tab when switching back from Notification view, as some tabs ignore the update events when not visible (e.g. Snapshots, HA)
Signed-off-by: Mihaela Stoica <mihaela.stoica@citrix.com>
- When clicking the action button on the grid, execute the action on the item that has been clicked, instead on using the grid's selected item, which may have not been updated yet.
- On multiselect (if the multiselect is allowed for the action), if the clicked item is in the grid's selection list, then execute the action on the whole list, otherwise on the clicked item only.
- This applies to both Updates and Alerts windows.
Signed-off-by: Mihaela Stoica <mihaela.stoica@citrix.com>
The error has been caused by the shadow multiplier field on Advanced Settings page: XenCenter thinks that the values has changed, and tries to save it, but this is not allowed for VM Admin users.
The solution is:
- use -1 as the signal value for unparseable string, instead of 1.0, which is actually a valid value;
- display the existing value without formatting it to 2 deciaml places;
Also corrected the validation function, as the shadow multiplier has to be greater than or equal to 1, not 0.1.
Signed-off-by: Mihaela Stoica <mihaela.stoica@citrix.com>
- Added check for null for sm.features in SR.SupportsTrim;
- Better error messages;
- Moved error messages from Messages to FriendlyNames;
- Removed the check for actions in progress from TrimSRCommand.CanExecute().
-
Signed-off-by: Mihaela Stoica <mihaela.stoica@citrix.com>
The operation applies to an SR. The button is on the Storage tab of the host/pool, and is entitled "Reclaim freed space".
It comes between the New SR and Properties buttons.
If the SR does not support TRIM , the button is invisible and the Properties button moves left to close up the gap.
Signed-off-by: Mihaela Stoica <mihaela.stoica@citrix.com>
- Reverted "CP-4951: CAR-100: Remove Rdp2 console" because Rdpclient 6.0 is not included in Windows Server 2003 SP2;
- Redone the fix for CA-123779 (Unhandled exception in Console Tab View), by moving RDPSetSettings() call inside a try..catch block, so we handle any exception thrown while setting the rdp client properties.
Signed-off-by: Mihaela Stoica <mihaela.stoica@citrix.com>
- XS60E009 has been replaced by XS62E006 and that the latter applies to all 6.x releases;
- 5.x hotfixes have changed, even though the version numbers are unchanged.
Signed-off-by: Mihaela Stoica <mihaela.stoica@citrix.com>
- Renamed “Checking can evacuate host status” precheck group to “Checking VM migration status”
- Prechecks page – check that all VMs have valid vCPU settings (i.e. number of vCPUs is a multiple of number of cores per socket).
- This check is included in the ‘Checking VM migration status” group
- If a VM has invalid vCPU settings, the precheck will display the problem with a solution to “Fix vCPU configuration” which opens the VM Properties dialog on the CPU page.
Signed-off-by: Mihaela Stoica <mihaela.stoica@citrix.com>
- Text on CPU page - changed to include topology.
- Summary page on the New VM Wizard – changed to include topology
Signed-off-by: Mihaela Stoica <mihaela.stoica@citrix.com>
- Added Topology drop-down box with available values for sockets and cores per socket, so that the number of vCPUs is divisible by the number of cores per socket.
E.g. if user specified 8 vCPUs, Cores per socket can only be 1, 2, 4, or 8.
- This updates VM's platform:cores-per-socket property.
- Can only be set when the VM is shut down (similar to number of vCPUs).
- Text on CPU page - changed to include topology.
Signed-off-by: Mihaela Stoica <mihaela.stoica@citrix.com>
When running XenCenter after a new installation, and the program's hash has changed (e.g. by .NET 4.0 upgrade), the previous settings are not automatically restored because they cannot be found (they are there, but in different folder).
We need to try and locate a config file from a previous installation, and if found, update the settings from there.
Signed-off-by: Mihaela Stoica <mihaela.stoica@citrix.com>
Made the radio button invisible for Creedence or higher XS hosts.
Removed previous StorageLink-related upgrade pre-checks and added (strict) check to prevent upgrade when StorageLink is used.
Signed-off-by: Gabor Apati-Nagy <gabor.apati-nagy@citrix.com>
- The VLAN can be set to 0 only for Creedence or greater hosts on the vSwitch backend.
- When VLAN 0 is selected, an info is shown next to the control, saying "VLAN 0 will receive all traffic not on any other VLAN"
- Also fixed an error on New Network Wizard, where the "VLAN in use" message was still visible when changing the NIC.
Signed-off-by: Mihaela Stoica <mihaela.stoica@citrix.com>
Renamed "Delete Pool" to "Make into standlone server"
Made sure it can never work with a multi-server pool
Removed confirmation dialog, as it is not destructive
Removed from context menu, as it is not important/common enough
existing or due to the host being a slave. Use the action description instead of
the action title to construct the error for failed connection results. Indentation.
Signed-off-by: Konstantina Chremmou <konstantina.chremmou@citrix.com>
If errors are found the error info at the bottom of the page shows up, however this should not happen while still checking and before any errors have been found.
Same applies for Prechecks page of Install Update Wizard.
Signed-off-by: Mihaela Stoica <mihaela.stoica@citrix.com>
of XenCenter and tasks started from outside and cancelling the former when exiting
or disconnecting from the pool.
Signed-off-by: Konstantina Chremmou <konstantina.chremmou@citrix.com>