- The problem was the Summary page was displayed before the lists of succeeded and failed actions have been populated (on the Completed event of each action).
- To fix it, we populate these lists after all the actions are completed, and on the event thread.
Signed-off-by: Mihaela Stoica <mihaela.stoica@citrix.com>
- Suppress reporting of success and failure for sub-actions:
The suppress history flag is set when the action is created and if is false (by default) the action is added to the history (the Events list).
In order to suppress history for the subactions, we need change all actions used in Edit pages so their constructor can set the SuppressHistory flag and then use these constructors with suppressHistory = true on all the implementations of IEditPage.SaveSettings() where an action is created
(then we need to remember to do the same everytime we introduce a new page and / or "save" action).
Signed-off-by: Mihaela Stoica <mihaela.stoica@citrix.com>
- Renamed “Checking can evacuate host status” precheck group to “Checking VM migration status”
- Prechecks page – check that all VMs have valid vCPU settings (i.e. number of vCPUs is a multiple of number of cores per socket).
- This check is included in the ‘Checking VM migration status” group
- If a VM has invalid vCPU settings, the precheck will display the problem with a solution to “Fix vCPU configuration” which opens the VM Properties dialog on the CPU page.
Signed-off-by: Mihaela Stoica <mihaela.stoica@citrix.com>
- Text on CPU page - changed to include topology.
- Summary page on the New VM Wizard – changed to include topology
Signed-off-by: Mihaela Stoica <mihaela.stoica@citrix.com>
Made the radio button invisible for Creedence or higher XS hosts.
Removed previous StorageLink-related upgrade pre-checks and added (strict) check to prevent upgrade when StorageLink is used.
Signed-off-by: Gabor Apati-Nagy <gabor.apati-nagy@citrix.com>
- The VLAN can be set to 0 only for Creedence or greater hosts on the vSwitch backend.
- When VLAN 0 is selected, an info is shown next to the control, saying "VLAN 0 will receive all traffic not on any other VLAN"
- Also fixed an error on New Network Wizard, where the "VLAN in use" message was still visible when changing the NIC.
Signed-off-by: Mihaela Stoica <mihaela.stoica@citrix.com>
If errors are found the error info at the bottom of the page shows up, however this should not happen while still checking and before any errors have been found.
Same applies for Prechecks page of Install Update Wizard.
Signed-off-by: Mihaela Stoica <mihaela.stoica@citrix.com>
common code to the base class BackgroundThreadBase; removed classes inheriting from
EventArgs; use Action/Action<T> delegates instead of EventHandler<T>.
Signed-off-by: Konstantina Chremmou <konstantina.chremmou@citrix.com>
Also GPU page on Pool properties dialogs should not be shown for non vGPU pools.
# HG changeset patch
# User Mihaela Stoica <Mihaela.Stoica@citrix.com>
# Date 1385743406 0
# Fri Nov 29 16:43:26 2013 +0000
# Node ID e28f9921a0a17efb1e3a8d185acf18b5b6e116b1
# Parent 59229250db34dd4cc1f34fbdab055467a1570f87
Signed-off-by: Konstantina Chremmou <konstantina.chremmou@citrix.com>
no forms are open. Since there is no event notifying about the Application.OpenForms
changing, created a new base class for all XenCenter dialogs and wizards with a
static event to which the main windw can subscribe.
Signed-off-by: Konstantina Chremmou <konstantina.chremmou@citrix.com>
- before leaving each page of the wizard, check if all selected VMs are still available for migration
Signed-off-by: Mihaela Stoica <mihaela.stoica@citrix.com>