- Try to get the analysis progress from cis (as an integer value representing percentage 0 - 100). If this function returns a valid progress less than 100, then we don't try to get the report analysis and continue to display "Analysis not yet available"
- If the progress is 100 then we get the analysis result and display it
- If the progress cannot be obtained, then we try to get the analysis result; If an empty result is obtained within 10 minutes from the upload completion, then we assume that the analysis is still in progress and continue to display "Analysis not yet available"
Signed-off-by: Mihaela Stoica <mihaela.stoica@citrix.com>
- XenCenter build system picks up the RPU hotfixes from Artifactory
- RPU001 and RPU002 replace XS62E006 and XS65ESP1006
- Removed hotfixes from the solution, moved XS60E001 to Branding folder
- also cleaned up code in the HotfixFactory class, removing MNR and Cowley hotfixes (not supported anymore)
Signed-off-by: Mihaela Stoica <mihaela.stoica@citrix.com>
All tests now pass, via a combination of
a) Use more up to date databases
b) Delete obsolete tests
c) Edit the version number in the databases (these should be fixed later)
- vendor check is not needed in the functions where we check whether to warn the users about different feature levels, as the pool join is not allowed if the vendors are different
- renamed some of the functions
- feature comparison is now done eight characters at a time, converted into a 32-bit integer
Signed-off-by: Mihaela Stoica <mihaela.stoica@citrix.com>
- Memory Tab uses GB units for values greater or equal to 1 GB, otherwise show in MB;
- Search Tab displays values in GB or MB in the same as the Memory Tab (e.g. 512 MB of 1 GB, 256 MB of 512 MB, 2.5 GB of 16 GB).
- The shiny bar present in the Memory Tab and in Memory Settings dialog shows the scaling in the following way: If smaller than 1 GB, then show as before, else show only labels with values multiples of half a GB.
- The units used in Memory Setting Dialog are set depending on the static_max. If it is greater or equal to 1 GB, then the units are GB, else MB. The user does not have the possibility of changing them.
As per code review, wherever there is an 'if' in the unit tests there should be an assertion for the 'else' branch as well
Signed-off-by: Mihaela Stoica <mihaela.stoica@citrix.com>
- XS60E009 has been replaced by XS62E006 and that the latter applies to all 6.x releases;
- 5.x hotfixes have changed, even though the version numbers are unchanged.
Signed-off-by: Mihaela Stoica <mihaela.stoica@citrix.com>
confusion (patch alerts and version alerts are both considered as server update alerts).
Signed-off-by: Konstantina Chremmou <konstantina.chremmou@citrix.com>
Added a smoke test category and assigned a selection of tests to this category
to get a broad coverage of XenCenter functionality which can be used to quickly
test XenCenter works on a given platform