mirror of
https://github.com/xcp-ng/xenadmin.git
synced 2024-12-30 07:40:13 +01:00
18fb723f6a
Signed-off-by: Mihaela Stoica <mihaela.stoica@citrix.com>
531 lines
20 KiB
C#
531 lines
20 KiB
C#
/* Copyright (c) Citrix Systems Inc.
|
|
* All rights reserved.
|
|
*
|
|
* Redistribution and use in source and binary forms,
|
|
* with or without modification, are permitted provided
|
|
* that the following conditions are met:
|
|
*
|
|
* * Redistributions of source code must retain the above
|
|
* copyright notice, this list of conditions and the
|
|
* following disclaimer.
|
|
* * Redistributions in binary form must reproduce the above
|
|
* copyright notice, this list of conditions and the
|
|
* following disclaimer in the documentation and/or other
|
|
* materials provided with the distribution.
|
|
*
|
|
* THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND
|
|
* CONTRIBUTORS "AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES,
|
|
* INCLUDING, BUT NOT LIMITED TO, THE IMPLIED WARRANTIES OF
|
|
* MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE ARE
|
|
* DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT HOLDER OR
|
|
* CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL,
|
|
* SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING,
|
|
* BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR
|
|
* SERVICES; LOSS OF USE, DATA, OR PROFITS; OR BUSINESS
|
|
* INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY,
|
|
* WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING
|
|
* NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE
|
|
* OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF
|
|
* SUCH DAMAGE.
|
|
*/
|
|
|
|
using System;
|
|
using System.Collections.Generic;
|
|
using System.Drawing;
|
|
using System.Text;
|
|
using System.Windows.Forms;
|
|
|
|
using XenAdmin.Actions;
|
|
using XenAdmin.Core;
|
|
using XenAPI;
|
|
using XenAdmin.Dialogs;
|
|
|
|
|
|
namespace XenAdmin.SettingsPanels
|
|
{
|
|
public partial class CPUMemoryEditPage : UserControl, IEditPage
|
|
{
|
|
private VM vm;
|
|
bool ShowMemory = false; // If this VM has DMC, we don't show the memory controls on this page.
|
|
|
|
private bool _ValidToSave = true;
|
|
private decimal _OrigMemory;
|
|
private long _OrigVCPUs;
|
|
private long _OrigVCPUsMax;
|
|
private long _OrigVCPUsAtStartup;
|
|
private decimal _OrigVCPUWeight;
|
|
private decimal _CurrentVCPUWeight;
|
|
private bool isVcpuHotplugSupported;
|
|
|
|
// Please note that the comboBoxVCPUs control can represent two different VM properties, depending whether the VM supports vCPU hotplug or not:
|
|
// If vCPU hotplug is supported, comboBoxVCPUs represents the maximum number of vCPUs (VCPUs_max). And the initial number of vCPUs is represented in comboBoxInitialVCPUs (which is only visible in this case)
|
|
// If vCPU hotplug is not supported, comboBoxVCPUs represents the initial number of vCPUs (VCPUs_at_startup). In this case we will also set the VM property VCPUs_max to the same value.
|
|
// We use the _OrigVCPUs variable to store the original value that populates this combo box (VCPUs_max if hotplug is allowed, otherwise VCPUs_at_startup)
|
|
|
|
private ChangeMemorySettingsAction memoryAction;
|
|
public bool ValidToSave
|
|
{
|
|
get
|
|
{
|
|
if (!_ValidToSave)
|
|
return false;
|
|
|
|
// Also confirm whether the user wants to save memory changes.
|
|
// If not, don't close the properties dialog.
|
|
if (HasMemoryChanged)
|
|
{
|
|
long mem = Convert.ToInt64(this.nudMemory.Value * Util.BINARY_MEGA);
|
|
memoryAction = BallooningDialogBase.ConfirmAndReturnAction(Program.MainWindow, vm, mem, mem, mem, (long)vm.memory_static_max, false);
|
|
if (memoryAction == null)
|
|
return false;
|
|
}
|
|
|
|
return true;
|
|
}
|
|
}
|
|
|
|
public CPUMemoryEditPage()
|
|
{
|
|
InitializeComponent();
|
|
|
|
Text = Messages.CPU_AND_MEMORY;
|
|
|
|
transparentTrackBar1.Scroll += new EventHandler(tbPriority_Scroll);
|
|
|
|
this.nudMemory.TextChanged += new EventHandler(nudMemory_TextChanged);
|
|
this.nudMemory.LostFocus += new EventHandler(nudMemory_LostFocus);
|
|
}
|
|
|
|
public Image Image
|
|
{
|
|
get
|
|
{
|
|
return Properties.Resources._000_CPU_h32bit_16;
|
|
}
|
|
}
|
|
|
|
void nudMemory_LostFocus(object sender, EventArgs e)
|
|
{
|
|
ValidateNud(nudMemory, (decimal)vm.memory_static_max / Util.BINARY_MEGA);
|
|
}
|
|
|
|
private void ValidateNud(NumericUpDown nud, Decimal defaultValue)
|
|
{
|
|
if (!String.IsNullOrEmpty(nud.Text.Trim()))
|
|
return;
|
|
|
|
nud.Value = defaultValue >= nud.Minimum && defaultValue <= nud.Maximum ?
|
|
defaultValue : nud.Maximum;
|
|
|
|
nud.Text = nud.Value.ToString();
|
|
}
|
|
|
|
void nudMemory_TextChanged(object sender, EventArgs e)
|
|
{
|
|
decimal val;
|
|
if (decimal.TryParse(nudMemory.Text, out val))
|
|
{
|
|
if (val >= nudMemory.Minimum && val <= nudMemory.Maximum)
|
|
nudMemory_ValueChanged(null, null);
|
|
else if (val > nudMemory.Maximum)
|
|
ShowMemError(true, false);
|
|
else
|
|
ShowMemError(false, false);
|
|
}
|
|
if (this.nudMemory.Text == "")
|
|
{
|
|
_ValidToSave = false;
|
|
}
|
|
else
|
|
{
|
|
_ValidToSave = true;
|
|
}
|
|
}
|
|
|
|
private void tbPriority_Scroll(object sender, EventArgs e)
|
|
{
|
|
_CurrentVCPUWeight = Convert.ToDecimal(Math.Pow(4.0d, Convert.ToDouble(transparentTrackBar1.Value)));
|
|
if (transparentTrackBar1.Value == transparentTrackBar1.Max)
|
|
_CurrentVCPUWeight--;
|
|
}
|
|
|
|
/// <summary>
|
|
/// Must be a VM.
|
|
/// </summary>
|
|
public void SetXenObjects(IXenObject orig, IXenObject clone)
|
|
{
|
|
vm = (VM)clone;
|
|
ShowMemory = Helpers.FeatureForbidden(vm, Host.RestrictDMC);
|
|
Repopulate();
|
|
}
|
|
|
|
public void Repopulate()
|
|
{
|
|
VM vm = this.vm;
|
|
|
|
Text = ShowMemory ? Messages.CPU_AND_MEMORY : Messages.CPU;
|
|
if (!ShowMemory)
|
|
lblMemory.Visible = panel2.Visible = MemWarningLabel.Visible = false;
|
|
else if (vm.power_state != vm_power_state.Halted && vm.power_state != vm_power_state.Running)
|
|
{
|
|
panel2.Enabled = false;
|
|
MemWarningLabel.Text = Messages.MEM_NOT_WHEN_SUSPENDED;
|
|
MemWarningLabel.ForeColor = SystemColors.ControlText;
|
|
MemWarningLabel.Visible = true;
|
|
}
|
|
|
|
// Since updates come in dribs and drabs, avoid error if new max and min arrive
|
|
// out of sync and maximum < minimum.
|
|
if (vm.memory_dynamic_max >= vm.memory_dynamic_min &&
|
|
vm.memory_static_max >= vm.memory_static_min)
|
|
{
|
|
decimal min = Convert.ToDecimal(vm.memory_static_min / Util.BINARY_MEGA);
|
|
decimal max = Convert.ToDecimal(vm.MaxMemAllowed / Util.BINARY_MEGA);
|
|
decimal value = Convert.ToDecimal(vm.memory_static_max / Util.BINARY_MEGA);
|
|
// Avoid setting the range to exclude the current value: CA-40041
|
|
if (value > max)
|
|
max = value;
|
|
if (value < min)
|
|
min = value;
|
|
this.nudMemory.Minimum = min;
|
|
this.nudMemory.Maximum = max;
|
|
this.nudMemory.Text = (this.nudMemory.Value = value).ToString();
|
|
}
|
|
|
|
Host currentHost = Helpers.GetMaster(this.vm.Connection);
|
|
if (currentHost != null)
|
|
{
|
|
// Show the performance warning about vCPUs > pCPUs.
|
|
// Don't show if the VM isn't running, since we don't know which server it will
|
|
// run on (and so can't count the number of pCPUs).
|
|
if ( vm.power_state == vm_power_state.Running
|
|
&& vm.VCPUs_at_startup > currentHost.host_CPUs.Count
|
|
&& !vm.IgnoreExcessiveVcpus)
|
|
{
|
|
lblVcpuWarning.Visible = true;
|
|
this.tableLayoutPanel1.RowStyles[1].SizeType = SizeType.Absolute;
|
|
this.tableLayoutPanel1.RowStyles[1].Height = 30;
|
|
}
|
|
else
|
|
{
|
|
lblVcpuWarning.Visible = false;
|
|
}
|
|
}
|
|
else
|
|
{
|
|
lblVcpuWarning.Visible = false;
|
|
}
|
|
|
|
isVcpuHotplugSupported = vm.SupportsVcpuHotplug;
|
|
|
|
label1.Text = GetRubric();
|
|
|
|
_OrigMemory = nudMemory.Value;
|
|
_OrigVCPUsMax = vm.VCPUs_max > 0 ? vm.VCPUs_max : 1;
|
|
_OrigVCPUsAtStartup = vm.VCPUs_at_startup > 0 ? vm.VCPUs_at_startup : 1;
|
|
_OrigVCPUWeight = _CurrentVCPUWeight;
|
|
_OrigVCPUs = isVcpuHotplugSupported ? _OrigVCPUsMax : _OrigVCPUsAtStartup;
|
|
_prevVCPUsMax = _OrigVCPUsMax; // we use variable in RefreshCurrentVCPUs for checking if VcpusAtStartup and VcpusMax were equal before VcpusMax changed
|
|
|
|
_CurrentVCPUWeight = Convert.ToDecimal(vm.VCPUWeight);
|
|
|
|
InitializeVcpuControls();
|
|
|
|
_ValidToSave = true;
|
|
}
|
|
|
|
private void InitializeVcpuControls()
|
|
{
|
|
lblVCPUs.Text = isVcpuHotplugSupported
|
|
? Messages.VM_CPUMEMPAGE_MAX_VCPUS_LABEL
|
|
: Messages.VM_CPUMEMPAGE_VCPUS_LABEL;
|
|
|
|
labelInitialVCPUs.Text = vm.power_state == vm_power_state.Halted
|
|
? Messages.VM_CPUMEMPAGE_INITIAL_VCPUS_LABEL
|
|
: Messages.VM_CPUMEMPAGE_CURRENT_VCPUS_LABEL;
|
|
|
|
labelInitialVCPUs.Visible = comboBoxInitialVCPUs.Visible = isVcpuHotplugSupported;
|
|
comboBoxInitialVCPUs.Enabled = isVcpuHotplugSupported &&
|
|
(vm.power_state == vm_power_state.Halted ||
|
|
vm.power_state == vm_power_state.Running);
|
|
|
|
comboBoxVCPUs.Enabled = comboBoxTopology.Enabled = vm.power_state == vm_power_state.Halted;
|
|
|
|
comboBoxTopology.Populate(vm.VCPUs_at_startup, vm.VCPUs_max, vm.CoresPerSocket, vm.MaxCoresPerSocket);
|
|
|
|
// CA-12941
|
|
// We set a sensible maximum based on the template, but if the user sets something higher
|
|
// from the CLI then use that as the maximum.
|
|
long maxVCPUs = vm.MaxVCPUsAllowed < _OrigVCPUs ? _OrigVCPUs : vm.MaxVCPUsAllowed;
|
|
PopulateVCPUs(maxVCPUs, _OrigVCPUs);
|
|
|
|
if (isVcpuHotplugSupported)
|
|
PopulateVCPUsAtStartup(_OrigVCPUsMax, _OrigVCPUsAtStartup);
|
|
|
|
transparentTrackBar1.Value = Convert.ToInt32(Math.Log(Convert.ToDouble(vm.VCPUWeight)) / Math.Log(4.0d));
|
|
panel1.Enabled = vm.power_state == vm_power_state.Halted;
|
|
}
|
|
|
|
private void PopulateVCPUComboBox(ComboBox comboBox, long min, long max, long currentValue, Predicate<long> isValid)
|
|
{
|
|
comboBox.BeginUpdate();
|
|
comboBox.Items.Clear();
|
|
for (long i = min; i <= max; ++i)
|
|
{
|
|
if (i == currentValue || isValid(i))
|
|
comboBox.Items.Add(i);
|
|
}
|
|
if (currentValue > max)
|
|
comboBox.Items.Add(currentValue);
|
|
comboBox.SelectedItem = currentValue;
|
|
comboBox.EndUpdate();
|
|
}
|
|
|
|
private void PopulateVCPUs(long maxVCPUs, long currentVCPUs)
|
|
{
|
|
PopulateVCPUComboBox(comboBoxVCPUs, 1, maxVCPUs, currentVCPUs, i => comboBoxTopology.IsValidVCPU(i));
|
|
}
|
|
|
|
private void PopulateVCPUsAtStartup(long max, long currentValue)
|
|
{
|
|
long min = vm.power_state == vm_power_state.Halted ? 1 : _OrigVCPUsAtStartup;
|
|
PopulateVCPUComboBox(comboBoxInitialVCPUs, min, max, currentValue, i => true);
|
|
}
|
|
|
|
private string GetRubric()
|
|
{
|
|
StringBuilder sb = new StringBuilder();
|
|
sb.Append(Messages.VM_CPUMEMPAGE_RUBRIC);
|
|
// add hotplug text
|
|
if (isVcpuHotplugSupported)
|
|
sb.Append(Messages.VM_CPUMEMPAGE_RUBRIC_HOTPLUG);
|
|
// add power state warning
|
|
if (vm.power_state != vm_power_state.Halted)
|
|
{
|
|
sb.AppendLine();
|
|
sb.AppendLine();
|
|
sb.Append(isVcpuHotplugSupported ? Messages.VM_CPUMEMPAGE_MAX_VCPUS_READONLY : Messages.VCPU_ONLY_WHEN_HALTED);
|
|
}
|
|
// add power state warning for Current number of vCPUs
|
|
if (isVcpuHotplugSupported && vm.power_state != vm_power_state.Halted && vm.power_state != vm_power_state.Running)
|
|
{
|
|
sb.Append(Messages.VM_CPUMEMPAGE_CURRENT_VCPUS_READONLY);
|
|
}
|
|
return sb.ToString();
|
|
}
|
|
|
|
public bool HasChanged
|
|
{
|
|
get { return HasVCPUChanged || HasMemoryChanged || HasTopologyChanged || HasVCPUsAtStartupChanged || HasVCPUWeightChanged; }
|
|
}
|
|
|
|
private bool HasMemoryChanged
|
|
{
|
|
get
|
|
{
|
|
return _OrigMemory != nudMemory.Value;
|
|
}
|
|
}
|
|
|
|
private bool HasVCPUChanged
|
|
{
|
|
get
|
|
{
|
|
return _OrigVCPUs != (long)comboBoxVCPUs.SelectedItem;
|
|
}
|
|
}
|
|
|
|
private bool HasVCPUWeightChanged
|
|
{
|
|
get
|
|
{
|
|
return _OrigVCPUWeight != _CurrentVCPUWeight;
|
|
}
|
|
}
|
|
|
|
private bool HasVCPUsAtStartupChanged
|
|
{
|
|
get
|
|
{
|
|
return isVcpuHotplugSupported && _OrigVCPUsAtStartup != (long)comboBoxInitialVCPUs.SelectedItem;
|
|
}
|
|
}
|
|
|
|
private bool HasTopologyChanged
|
|
{
|
|
get
|
|
{
|
|
return vm.CoresPerSocket != comboBoxTopology.CoresPerSocket;
|
|
}
|
|
}
|
|
|
|
private long SelectedVcpusMax
|
|
{
|
|
get
|
|
{
|
|
return (long)comboBoxVCPUs.SelectedItem;
|
|
}
|
|
}
|
|
|
|
private long SelectedVcpusAtStartup
|
|
{
|
|
get
|
|
{
|
|
return isVcpuHotplugSupported ? (long)comboBoxInitialVCPUs.SelectedItem : (long)comboBoxVCPUs.SelectedItem;
|
|
}
|
|
}
|
|
|
|
public AsyncAction SaveSettings()
|
|
{
|
|
List<AsyncAction> actions = new List<AsyncAction>();
|
|
|
|
if (HasVCPUWeightChanged)
|
|
{
|
|
vm.VCPUWeight = Convert.ToInt32(_CurrentVCPUWeight);
|
|
}
|
|
|
|
if (HasVCPUChanged || HasVCPUsAtStartupChanged)
|
|
{
|
|
actions.Add(new ChangeVCPUSettingsAction(vm, SelectedVcpusMax, SelectedVcpusAtStartup));
|
|
}
|
|
|
|
if (HasTopologyChanged)
|
|
{
|
|
vm.CoresPerSocket = comboBoxTopology.CoresPerSocket;
|
|
}
|
|
|
|
if (HasMemoryChanged)
|
|
{
|
|
actions.Add(memoryAction); // Calculated in ValidToSave
|
|
}
|
|
|
|
if (actions.Count == 0)
|
|
return null;
|
|
else if (actions.Count == 1)
|
|
return actions[0];
|
|
else
|
|
{
|
|
MultipleAction multipleAction = new MultipleAction(vm.Connection, "", "", "", actions, true);
|
|
return multipleAction;
|
|
}
|
|
}
|
|
|
|
/** Show local validation balloon tooltips */
|
|
public void ShowLocalValidationMessages() { }
|
|
|
|
/** Unregister listeners, dispose balloon tooltips, etc. */
|
|
public void Cleanup() { }
|
|
|
|
/// <summary>
|
|
/// Shows the warning dialog about vCPUs > pCPUs.
|
|
/// </summary>
|
|
private void lblVcpuWarning_LinkClicked(object sender, LinkLabelLinkClickedEventArgs e)
|
|
{
|
|
if (vm == null)
|
|
{
|
|
System.Diagnostics.Trace.Assert(false, "Selected object should be a vm");
|
|
}
|
|
else
|
|
{
|
|
new Dialogs.VcpuWarningDialog(vm).ShowDialog();
|
|
this.Refresh();
|
|
}
|
|
}
|
|
|
|
private void nudMemory_ValueChanged(object sender, EventArgs e)
|
|
{
|
|
ShowMemError(false, true);
|
|
}
|
|
|
|
private void ShowMemError(bool showAlways, bool testValue)
|
|
{
|
|
if (vm == null || !ShowMemory)
|
|
return;
|
|
|
|
Host selectedAffinity = vm.Connection.Resolve<Host>(vm.power_state == vm_power_state.Running ? vm.resident_on : vm.affinity);
|
|
if (selectedAffinity != null)
|
|
{
|
|
Host_metrics host_metrics = vm.Connection.Resolve<Host_metrics>(selectedAffinity.metrics);
|
|
if ((showAlways || (testValue && (host_metrics != null && (double)host_metrics.memory_total < (double)nudMemory.Value * (double)Util.BINARY_MEGA))))
|
|
{
|
|
MemWarningLabel.Visible = true;
|
|
}
|
|
else
|
|
{
|
|
MemWarningLabel.Visible = false;
|
|
}
|
|
}
|
|
}
|
|
|
|
private void comboBoxVCPUs_SelectedIndexChanged(object sender, EventArgs e)
|
|
{
|
|
ShowVcpuError(false, true);
|
|
comboBoxTopology.Update((long)comboBoxVCPUs.SelectedItem);
|
|
ValidateVCPUSettings();
|
|
RefreshCurrentVCPUs();
|
|
}
|
|
|
|
private void ShowVcpuError(bool showAlways, bool testValue)
|
|
{
|
|
if (vm == null || !comboBoxVCPUs.Enabled)
|
|
return;
|
|
Host selectedAffinity = vm.Home();
|
|
if (selectedAffinity == null && vm.Connection.Cache.Hosts.Length == 1)
|
|
selectedAffinity = vm.Connection.Cache.Hosts[0];
|
|
|
|
if (showAlways || (testValue && (selectedAffinity != null && selectedAffinity.host_CPUs.Count < (long)comboBoxVCPUs.SelectedItem)))
|
|
{
|
|
VCPUWarningLabel.Visible = true;
|
|
}
|
|
else
|
|
{
|
|
VCPUWarningLabel.Visible = false;
|
|
}
|
|
}
|
|
|
|
private long _prevVCPUsMax;
|
|
|
|
private void RefreshCurrentVCPUs()
|
|
{
|
|
// refresh comboBoxInitialVCPUs if it's visible and populated
|
|
if (comboBoxInitialVCPUs.Visible && comboBoxInitialVCPUs.Items.Count > 0)
|
|
{
|
|
// VcpusAtStartup is always <= VcpusMax
|
|
// So if VcpusMax is decreased below VcpusAtStartup, then VcpusAtStartup is decreased to that number too
|
|
// If VcpusAtStartup and VcpusMax are equal, and VcpusMax is changed, then VcpusAtStartup is changed to match
|
|
// But if the numbers are unequal, and VcpusMax is changed but is still higher than VcpusAtStartup, then VcpusAtStartup is unchanged
|
|
var newValue = SelectedVcpusAtStartup;
|
|
|
|
if (SelectedVcpusMax < SelectedVcpusAtStartup)
|
|
newValue = SelectedVcpusMax;
|
|
else if (SelectedVcpusAtStartup == _prevVCPUsMax && SelectedVcpusMax != _prevVCPUsMax)
|
|
newValue = SelectedVcpusMax;
|
|
|
|
PopulateVCPUsAtStartup(SelectedVcpusMax, newValue);
|
|
_prevVCPUsMax = SelectedVcpusMax;
|
|
}
|
|
}
|
|
|
|
public String SubText
|
|
{
|
|
get
|
|
{
|
|
return ShowMemory ?
|
|
String.Format(Messages.CPU_AND_MEMORY_SUB, SelectedVcpusAtStartup, nudMemory.Value) :
|
|
String.Format(Messages.CPU_SUB, SelectedVcpusAtStartup);
|
|
}
|
|
}
|
|
|
|
private void comboBoxTopology_SelectedIndexChanged(object sender, EventArgs e)
|
|
{
|
|
ValidateVCPUSettings();
|
|
}
|
|
|
|
private void ValidateVCPUSettings()
|
|
{
|
|
if (comboBoxVCPUs.SelectedItem != null)
|
|
labelInvalidVCPUWarning.Text = VM.ValidVCPUConfiguration((long)comboBoxVCPUs.SelectedItem, comboBoxTopology.CoresPerSocket);
|
|
}
|
|
}
|
|
}
|