mirror of
https://github.com/VictoriaMetrics/VictoriaMetrics.git
synced 2024-11-27 02:46:47 +01:00
e144a2b062
Signed-off-by: Artem Navoiev <tenmozes@gmail.com>
4.5 KiB
4.5 KiB
weight | title | menu | ||||||||
---|---|---|---|---|---|---|---|---|---|---|
5 | VictoriaMetrics Cloud: Tier Parameters and Flag Parameters Configuration |
|
The tier parameters are derived from testing in typical monitoring environments, ensuring they are optimized for common use cases.
VictoriaMetrics Cloud Tier Parameters
Parameter | Maximum Value | Description |
---|---|---|
Data Ingestion Rate | Per Tier Limits | Number of time series ingested per second. |
Active Time Series Count | Per Tier Limits | Number of active time series that received at least one data point in the last hour. |
Read Rate | Per Tier Limits | Number of datapoints retrieved from the database per second. |
New Series Over 24 Hours (churn rate) | <= Active Time Series Count |
Number of new series created in 24 hours. High churn rate leads to higher resource consumption. |
Concurrent Requests per Token | <= 600 |
Maximum concurrent requests per access token. It is recommended to create separate tokens for different clients and environments. This can be adjusted via support. |
For a detailed explanation of each parameter, visit the guide on Understanding Your Setup Size.
Flag Parameters Configuration
Flag | Default Value | Description |
---|---|---|
Max Label Value Length | <= 1kb (Default: 4kb ) |
Maximum length of label values. Longer values are truncated. Large label values can lead to high RAM consumption. This can be adjusted via support. |
Max Labels per Time Series | <= 30 |
Maximum number of labels per time series. Excess labels are dropped. Higher values can increase cardinality and resource usage. This can be configured in deployment settings. |