* CP-35838: Add health check precheck into RPU wizard
* CP-35838: Add disable Health Check in RPU precheck warning
Signed-off-by: Ji Jiang <ji.jiang@citrix.com>
Not sure why I had added that since the containing protected method is probably
more relevant as a static method in the Problem class.
Signed-off-by: Konstantina Chremmou <konstantina.chremmou@citrix.com>
Also, try plugging PBDs only for the host in question (other hosts are not necessary,
as the PBDs are re-checked for any previously evacuated VMs before repatriation).
Signed-off-by: Konstantina Chremmou <konstantina.chremmou@citrix.com>
* Hid properties from the designer and renamed them because they give the wrong impression.
* Fixed some inefficiencies around the NetworkComboboxItem.
- Move NetworkComboBoxItem into the NetworkComboBox class.
- Moved XenAdmin.Dialogs.NetworkComboBoxItem into the VIFDialog class and made it
private to avoid ambiguousness with the public XenAdmin.Controls.NetworkComboBox.NetworkComboboxItem.
- Create a NetworkComboBoxItem only if needed and assign its name at construction time.
- Add method to select a NetworkComboBoxItem and property to return the SelectedNetwork.
* CA-339233: Do not allow selection of networks while they're locked.
Signed-off-by: Konstantina Chremmou <konstantina.chremmou@citrix.com>
- Improvements to progress reporting (CA-65894).
- Added some logging.
- Use the connection cache instead of making server calls.
- Moved some methods to the string utilities and added unit tests.
Signed-off-by: Konstantina Chremmou <konstantina.chremmou@citrix.com>
Previously this was not possible due to XenModel-XenOvfTransport cyclical references.
Signed-off-by: Konstantina Chremmou <konstantina.chremmou@citrix.com>
- Use CommandButtons on the HA TabPage for configuring/disabling HA.
- Added menu item to disable HA.
- There is no point in hiding the buttons on the HA TabPage when the corresponding
menu items are available. They should rather offer the same user experience.
- Added RBAC page to the HaWizard to avoid unnecessary SR scanning only to be told
that one cannot proceed.
- Show RBAC error dialog if the user does not have permission to launch the
EditVmPriorities dialog.
Signed-off-by: Konstantina Chremmou <konstantina.chremmou@citrix.com>
- Use a plain list to store update alerts and, where possible, fire a collection
change event only after a bulk change and not every time a single object is added
or removed.
- Fixed issue where dismissed updates were stored in the config of all connected
pools, even of those where the update did not apply.
- Corrected RBAC checks for update dismissal.
- Fixed enabled state of dismiss buttons.
Signed-off-by: Konstantina Chremmou <konstantina.chremmou@citrix.com>
Also, remove the upgrade methods from the resource files since they are not meant
to be translated.
Signed-off-by: Konstantina Chremmou <konstantina.chremmou@citrix.com>
Also: removed unused method; some property modernisation; removed class
LiveMigrateOptionsVmMapping which was rather complicating things.
Signed-off-by: Konstantina Chremmou <konstantina.chremmou@citrix.com>
Also, reduced visibility of the methods moving between wizard pages to avoid
creating complex situations.
Signed-off-by: Konstantina Chremmou <konstantina.chremmou@citrix.com>
* Replaced LicenseWarningDialog with a simple WarningDialog.
* Replaced VcpuWarningDialog with a simple WarningDialog.
* Replaced RemoveCrashdumpsWarningDialog with a simple WarningDialog.
* Replaced UsbUsageDialog with a simple WarningDialog.
* Replaced WlbDeleteReportSubscriptionDialog with a simple WarningDialog. Added null checks to event invocation.
* Replaced DisableWlbDialog with a simple Warning dialog.
* Replaced ConnectionRefusedDialog with a simple Error dialog.
* Replaced UserDeviceDialog with a simple Warning dialog.
* Replaced RevertDialog with a simple Warning dialog.
* Removed unused dialogs.
Signed-off-by: Konstantina Chremmou <konstantina.chremmou@citrix.com>
Also, stop boxing Bitmap into Image so as to avoid casting wherever it is called.
Signed-off-by: Konstantina Chremmou <konstantina.chremmou@citrix.com>
The result was that numbers were changing suddenly; in cases of slow connections,
a user could make a selection before the scan was over.
Signed-off-by: Konstantina Chremmou <konstantina.chremmou@citrix.com>
This fixes various workflow bugs and disallows re-attaching GFS2 SR if clustering
is disabled.
Signed-off-by: Konstantina Chremmou <konstantina.chremmou@citrix.com>
Override the polymorphic methods of XenTabPage on the ballooning wizard;
No need to exposed the memory values outside the VMMemoryControlsEdit class.
Signed-off-by: Konstantina Chremmou <konstantina.chremmou@citrix.com>
Replace with help links where necessary or convenient. Also:
- Registered unused event.
- Minor refactoring to: make the InstallToolsCommand.CanExecute clearer; use
local methods.
Signed-off-by: Konstantina Chremmou <konstantina.chremmou@citrix.com>
- NetworkDetails page: reworked it to fix NumericUpdown validation and messages (CA-192746).
- SelectNetworkType page: moved warnings closer to the corresponding network types,
fixed wrong label enabled state and made enablement logic more explicit.
- All pages: property modernisation and control layout tweaks (mostly margins).
Signed-off-by: Konstantina Chremmou <konstantina.chremmou@citrix.com>
- Handle validation for OVF files with a name different from the containing
OVA package. Other corrections to wrong validation logic.
- Show validation warnings on a dialog that can be turned off.
- Clean up extracted files after an OVA package has been imported.
- Plus code refactoring and simplification.
Signed-off-by: Konstantina Chremmou <konstantina.chremmou@citrix.com>
- Renamed button to make it more discoverable.
- Placed the controls on a table layout panel for better response to wizard resizing.
Signed-off-by: Konstantina Chremmou <konstantina.chremmou@citrix.com>
If a host cannot be evacuated because other hosts in the pool are maintenance mode and pending a reboot following an update installation, then include instructions to reboot those hosts and then press Retry.
Also updated the text for the Manual mode, removing the reference to installing other updates and doing a reboot manually at the end, because that won't be always possible, due to the fact that now we put the hosts in maintenance mode before installing the update.
Signed-off-by: Mihaela Stoica <mihaela.stoica@citrix.com>
- Fixed button enablement on the IntraPoolCopy page.
- Regression on the NewDiskDialog were selection was considered valid
even if the SR was disabled.The SrSelectionChanged and SelectedIndexChanged
were fired in the wrong order. To fix this the event SrSelectionChanged
is removed (in reality after the refactoring in 5b79b1dc94
it became obsolete).
Signed-off-by: Konstantina Chremmou <konstantina.chremmou@citrix.com>
- Removed DebugHelp. The user settings are normally not meant for debugging code.
- Moved HelpId logic from the main window to the tab pages.
Signed-off-by: Konstantina Chremmou <konstantina.chremmou@citrix.com>
- Moved path validation checks from the wizard to its last page (planning
to remove XenWizardBase.FinishCancelled in future).
- If the directory did not exist, the user saw a message about inability
to write a file which was misleading. Check directory existence explicitly.
- Populate the last wizard page on load rather than on construction to
avoid unnecessary validations.
- Save in the settings the report output directory, not the filename.
Signed-off-by: Konstantina Chremmou <konstantina.chremmou@citrix.com>
Also, minor layout correction, and usability enhancement: do not disable
the controls under the radio button when the latter is deselected.
Signed-off-by: Konstantina Chremmou <konstantina.chremmou@citrix.com>
The warning is visible for vss scheduled snapshots on Quebec or newer hosts (these would be snapshots created before the host has been upgraded).
Also corrected a typo in a function name.
Signed-off-by: Mihaela Stoica <mihaela.stoica@citrix.com>
- This fixes the issue where we create a multiple action to delete the update installation files, but the sub-actions list contains null values because the connection to the host has been lost
Signed-off-by: Mihaela Stoica <mihaela.stoica@citrix.com>
* CP-30958: Initial implementation of the Conversion Manager in XenCenter.
* Corrections following review and improvements.
* Further corrections and improvements.
Signed-off-by: Konstantina Chremmou <konstantina.chremmou@citrix.com>
The blurbs should be user-centric rather than developer-centric.
No need to disable the page controls in the absence of signature/manifest
since the whole page becomes disabled in that case.
Signed-off-by: Konstantina Chremmou <konstantina.chremmou@citrix.com>
- Verification of appliance files in chunks to avoid StreamTooLong exception.
- Disposal of HashAlgorithms and X509Certificates after use.
- General code simplification.
Signed-off-by: Konstantina Chremmou <konstantina.chremmou@citrix.com>
In the CrossPoolMigrateCanMigrateFilter a WebException can be raised if the host cannot be reached to execute the API call that asserts is the VM can be migrated there. With these changes, we catch any exception (not just Failure) and mark the VM as not migratable (because we couldn't assert if it can be migrated to that host).
Also fixed other places where the same error might occur.
Signed-off-by: Mihaela Stoica <mihaela.stoica@citrix.com>
Also, fixed issue where uploading a supp-pack resulted in a perpetually
pending action if the file had disappeared from the disk.
Signed-off-by: Konstantina Chremmou <konstantina.chremmou@citrix.com>
CA-320203: Fixed the update wizard failure when installing two cumulative updates
The issue was that when installing 2 new versions in one go (e.g. two cumulative updates), the installation succeeds on master but it cannot continue on slaves, because it cannot find the first CU update anymore.
The fix is to refresh the update record before applying the update, with the record found in the cache. Also, if there is no update in the cache, try to re-introduce the update.
Signed-off-by: Mihaela Stoica <mihaela.stoica@citrix.com>
- Made storage selector blurb for XVA import a bit more informative.
- A simple checkbox for starting the new VMS on the finish page is adequate.
- Typos. Property modernisation.
Signed-off-by: Konstantina Chremmou <konstantina.chremmou@citrix.com>
When running the XenCenter version precheck, calculate the higher server version that will be installed (by looking at the update sequence) and use this for checking the XenCenter version compatibility.
Signed-off-by: Mihaela Stoica <mihaela.stoica@citrix.com>
- if there is only one host in the selected pool, then preselect it.
- make sure that the Next button is enabled when a target host is selected.
Signed-off-by: Mihaela Stoica <mihaela.stoica@citrix.com>
* CP-31063: Add support for multiple vGPU
(incomplete)
Signed-off-by: Mihaela Stoica <mihaela.stoica@citrix.com>
* CP-31063: Add support for multiple vGPU
(part 2)
Signed-off-by: Mihaela Stoica <mihaela.stoica@citrix.com>
* AddVGPUDialog
Signed-off-by: Michael Z <michael.zhao@citrix.com>
* Update bindings.
Signed-off-by: Michael Z <michael.zhao@citrix.com>
* REQ-720: Initial implementation of AddVgpuDialog.
Signed-off-by: Michael Z <michael.zhao@citrix.com>
* Improve the handling of buttons and combobox. Fix comments.
Signed-off-by: Michael Z <michael.zhao@citrix.com>
* Fix comments.
Signed-off-by: Michael Z <michael.zhao@citrix.com>
* CA-317856: Ensure that VMs are repatriated after all hotfixes are applied and the host has been rebooted.
- there is no need to remove the "reboot host" plan actions from the delayed actions list, because the action itself has code to check if a reboot is actually needed.
* CA-317856: Only add the "Exit maintenance mode" progress step if the host is in maintenance mode at that point.
- moved the AddProgressStep() call inside the function that checks if anything needs to be done (i.e. is host needs to be enables)
Signed-off-by: Mihaela Stoica <mihaela.stoica@citrix.com>
* Refactored the VIFDialog to fix various problems:
- Launch the dialog in using blocks.
- Event GotFocus is not meant to be handled directly in the code.
- Populate the dialog in the OnLoad override instead of the constructor
as this causes problems at design time.
- Popping up an error message for duplicate MAC on combobox item
selection or textbox text change is not optimal UX. Perform this
check once when closing the form. Additionally the parent form of the
pop up should be the dialog, not the main window.
- The validation messages are not obvious to the user because they are
hidden in the tooltip of a disabled button. Show them inline instead.
- There is no need to create commands for VIF creation/change; use
the relevant actions instead.
Signed-off-by: Konstantina Chremmou <konstantina.chremmou@citrix.com>
* Corrections as per code review plus some more code tidy and refactoring.
- Added option to suppress Create/DeleteVIFActions
- Use property RebootRequired to indicate hot-plugging is unavailable
(assigning various objects of different types to the Result of the action
during its run may cause confusion).
Signed-off-by: Konstantina Chremmou <konstantina.chremmou@citrix.com>
- On the dialog show the next run time in both the client's and the server's local time zone.
- On the VMSS frequency page allow the user to pick the schedule in the client's
local time zone and show then next run time in both the client's and the server's local time zone.
- Refactoring to fix workflow and class design, reduce amount of code and simplify logic.
- Various layout improvements.
Signed-off-by: Aaron Robson aaron.robson@citrix.com
Signed-off-by: Konstantina Chremmou <konstantina.chremmou@citrix.com>
- When asserting if a VM can be migrated to a pool we don't have to check all the hosts in the pool at this point, we can enable the pool when we find the first host where migration is possible; we will check the rest of the hosts only if that pool is selected.
- If the destination pool is older than the source, then we don't need to do any server calls because we know that migration to an older host is not allowed.
Signed-off-by: Mihaela Stoica <mihaela.stoica@citrix.com>
- hide the boot mode control if there is only one option (BIOS boot);
- add text "(experimental)" to the experimental options (in the radio button text);
- if an option is disabled, then hide the experimantal warning, as there is already a note saying why it is disabled;
- more detailed experimental warning.
Signed-off-by: Mihaela Stoica <mihaela.stoica@citrix.com>
If a host needs to be rebooted after the update application, and the update is not a live patch, then do the host evacuation before applying the update.
Signed-off-by: Mihaela Stoica <mihaela.stoica@citrix.com>
Thsi fixes the bug where XenCenter shows connection failure in the RPU when retrying an upgrade
Signed-off-by: Mihaela Stoica <mihaela.stoica@citrix.com>
of the hosts to be upgraded and not only on the first one in the list.
For this purpose, the test has been moved to the prechecks, and the
failures are now shown as a non-fixable problem.
Further, specification of the network location of the installer files
has moved closer to the upgrade mode selection.
Also, moved the hotfix and upgrade related checks immediately after the
host liveness check.
Signed-off-by: Konstantina Chremmou <konstantina.chremmou@citrix.com>
Moved these errors to the FriendlyNames, which is reserved for resources with
keys coming verbatim from the server.
Some code efficiency corrections to the page's workflow.
Signed-off-by: Konstantina Chremmou <konstantina.chremmou@citrix.com>
because it only manages friendly names; moved it closer to the relevant resource files.
Signed-off-by: Konstantina Chremmou <konstantina.chremmou@citrix.com>
* CP-30335: Fix RPU wizard tests
* CP-30335: Add abstract class WarningWithMoreInfo and use it for two of the existing Warnings
* CP-30335: Add a new precheck which produces a warning if the Dom0 memory after the upgrade will be increased.
- if the Dom0 memory after the upgrade is known, then a warning is shown if this is higher than the current memory, regardless of the version of the upgrade
- if the Dom0 memory after the upgrade is not known (e.g. because the rpu plugin does not have the function that returns this), then a warning is shown if upgrading from a pre-Naples version
* CP-30335: Add a more detailed error message if the host evacuation fails due to not enough memory in the RPU and Patching wizards
* CP-30335: Add branding variable for version 8.0
Signed-off-by: Mihaela Stoica <mihaela.stoica@citrix.com>
- Moved Install Location (RollingUpgradeWizard_SelectInstallMethod) page immediatelly after the Upgrade Mode page (and before the Prechecks page)
- Added a new page, called Extras, which contains the updates and supp pack installation options. These options have been moved here from the "Upgrade Mode" and "Ready To Upgrade" pages. This page is also inserted before the Prechecks
- There is no "Ready To Upgrade" page anymore. So the wizard pages are:
- when automatic mode is selected: Before You Start, Select Pools, Upgrade Mode, Installer Location, Extras, Prechecks, Apply Upgrade.
- when manual mode is selected: Before You Start, Select Pools, Upgrade Mode, Extras, Prechecks, Apply Upgrade.
Signed-off-by: Mihaela Stoica <mihaela.stoica@citrix.com>
or upgrade process (either when cancelling the wizard itself or when exiting
the application). Rephrased confirmation message for clarity.
Signed-off-by: Konstantina Chremmou <konstantina.chremmou@citrix.com>
(either when cancelling the wizard itself or exiting the application).
Implemented in the first instance for compiling the server status report.
Signed-off-by: Konstantina Chremmou <konstantina.chremmou@citrix.com>
- removal of the SystemStatusAction launching the individual SingleHostStatusActions,
because the connection was set incorrectly to the last one of the selected
connections and, if an error occurred to that connection, the data collection
for all of them failed.
- proper handling of HTTP.CancelledExceptions.
- replacement of the FlickerFreeListBox by the more versatile DataGridViewEx.
- corrections to reporting progress for individual hosts as well as page totals.
- made collection of client side data more obvious.
Signed-off-by: Konstantina Chremmou <konstantina.chremmou@citrix.com>
set by the caller. Test corrections so they don't time out due to blocking
open dialogs. Some tidying up.
Signed-off-by: Konstantina Chremmou <konstantina.chremmou@citrix.com>
Since we support checkpoint of Nvidia VGPU dedicated VMs, the conditions
text when new a VMSS needs to be refined.Note that Intel and AMD dedicated
GPUs VMs still be blocked for checkpoint.
Signed-off-by: Min Li <min.li1@citrix.com>
* Simplification: use auto-properties.
* Removed unnecessary null check. Converted private methods to linq method chain.
* Removed unused file. Added null check.
* Corrected property names as it was difficult to distinguish between the alert,
the patch and the filepath.
* Removed duplicate lock.
* CA-296490: Rewrote the logic uploading single updates so as to facilitate uploading to multiple pools in parallel.
* Corrections as per code review.
* Account for the case of uploading from disk legacy updates that do not correspond to an update alert.
Removed unfriendly error messages (the failure is written out in the logs anyway).
* Wizard test corrections and some modernising:
- Only call cancel on the last page if the test allows us to.
- Do finish the UpdatesWizard test.
- Finish the RunWizardKeyboardTests using key strokes instead of button clicks.
- Ensure the Cancel/Previous buttons do not have focus when sending an Enter stroke.
- Use optional parameters in the WizardTest constructor and string interpolation.
* Renamed badly named property.
* Improved code cloning VMs by assigning new opaque_refs to cloned VBDs.
Compacted test object provider: use optional parameters instead of method overloads.
* Modifications to prevent multiple update of enabled state and ensure the wizard
buttons are updated last.
Signed-off-by: Konstantina Chremmou <konstantina.chremmou@citrix.com>
Use two separate feature flags, `guefi` and `guefi-secureboot`, with the following rules:
- If the feature is disabled, then the option is hidden in XenCenter.
- If the feature is enabled and experimental, then the option is visible and a warning is displayed in XenCenter (in the New Vm and Import wizards).
Also show the reason why a boot mode option is greyed out (when the uefi/uefi-secure boot mode is not supported in the selected template).
(On the Page_InstallationMedia control, I moved the BootModeContol and PvBootBox controls inside the TableLayoutPanel, to allow better alignment and for better visibility in the design mode)
Signed-off-by: Mihaela Stoica <mihaela.stoica@citrix.com>
- In the New VM wizard, the boot mode control is only visible for Naples or greater hosts
- In the Import wizard, I had moved the boot mode options to a separate page, added after the target selection page, to allow the version check. The new "Boot options" page is only added for Naples or greater hosts.
Signed-off-by: Mihaela Stoica <mihaela.stoica@citrix.com>
* CP-29856: Support minimum number of vCPUs in guest templates
- Show a warning if the user wants to set a smaller number of vCPUs than the minimum specified in the template
- Add a null check; Set the warning label text before making it visible to avoid flickering.
Signed-off-by: Mihaela Stoica <mihaela.stoica@citrix.com>